• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
PDF - This Chapter
PDF - This Chapter

Hybrid Converter Topology For Power Factor
Hybrid Converter Topology For Power Factor

... factor correction (PFC) for AC drives which is fed through a diode bridge rectifier from a single phase AC mains. In this project both buck and boost converter topologies are combined together and operated alternatively according to the rectified DC input voltage level. AC drives are mostly operatin ...
Overview of Custom Power Applications
Overview of Custom Power Applications

et-01 timer wiring instructions
et-01 timer wiring instructions

...   Connect AC or DC voltage to these terminals   (12-24V depending on magnet or strike used.     IMPORTANT: When using AC power source,    use 12VAC for 12VDC magnetic lock - Do not    exceed 12VAC input for 12VDC magnetic lock;    use 16-20VAC for 24VDC magnetic lock - Do not    exceed 20VAC input f ...
EE431 Noise Homework
EE431 Noise Homework

... noise voltage by a factor of 2.0. A reduction to 0.3 K (hard to do!) would reduce the noise voltage by a factor of 10. In a more real example the device being cooled might have a temperature much higher than room temperature. Then cooling it down to 70 K can make a substantial reduction in noise. ...
Copper Testing
Copper Testing

Industrial Revolution
Industrial Revolution

... Large soft dome tweeter delicately produces mid to high frequencies while keeping a low profile stance ...
DRP024V060W1AZ Datasheet
DRP024V060W1AZ Datasheet

... compact body at only 32mm, which is both shock and vibration resistant according to IEC 60068-2 standard. The DRP024V060W1AZ operates within a wide temperature range from -20°C to +80°C and universal AC input voltage range from 85Vac to 264Vac, the power will not de-rate for the entire input voltage ...
New Approaches to CATV System Powering
New Approaches to CATV System Powering

... to provide power to 4 KPR's (50 watts each) in the cascade. No degradation of the cable signals was observed, and no adverse effects on the existing 60 volt - 60 Hz power supplies or amplifiers were noted. CONCLUSION It has been demonstrated that there are viable alternatives to standard 60 volt - 6 ...
UniStar V Single Phase
UniStar V Single Phase

... The UPS units can be connected in parallel and shall share the current and load between them. In a system with several UPS units connected in parallel, there is a single MASTER unit and the remaining units are SLAVE units. The UPS units must be the same rating and the MASTER is chosen on start-up. T ...
1C.3.1—Voltage Balance
1C.3.1—Voltage Balance

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... power electronics system such as adjustable speed drive. Integration of non-conventional generation technologies such as fuel cells, wind turbines and photo-voltaic with utility grids often requires power electronic interfaces. The power electronic system also contributes to power quality problem. U ...
Switch_Mode_Inverters
Switch_Mode_Inverters

... Harmonics in the Inverter Output Voltage VAo The harmonics in the inverter output voltage waveform appear as sidebands, centered around the switching frequency and its multiples, that is, around harmonics mf, 2mf, 3mf, and so on. This general pattern holds true for all values of ma in the range 0-1 ...
Datasheet
Datasheet

Full Article
Full Article

P85327C
P85327C

... recommends that the strobes installed should not present a composite flash rate in the field of view which exceeds five (5) hz at the operating voltage of the strobes. Cooper wheelock also strongly recommends that the intensity and composite flash rate of installed strobes comply with levels establi ...
ASYC IV Portable Digital Multimeters 6,000 cts – 60.000 cts MTX 3290/MTX 3291,
ASYC IV Portable Digital Multimeters 6,000 cts – 60.000 cts MTX 3290/MTX 3291,

... 4. Connect the black cord to the “COM” input and the red cord to the “V” input. The presence of the symbol indicates that the filter is active. ...
RHA_VSC_PEN_PIR - Industrial Controls Knowledge Base
RHA_VSC_PEN_PIR - Industrial Controls Knowledge Base

RF3166D DUAL-BAND GSM900/DCS POWER AMP MODULE Features
RF3166D DUAL-BAND GSM900/DCS POWER AMP MODULE Features

... order to ensure minimum switching transients. The VBATT tracking circuit is integrated into the CMOS controller and requires no additional input from the user. Due to reactive output matches, there are output power variations across frequency. There are a number of components that can make the effec ...
LAB#8 - SIUE
LAB#8 - SIUE

PXE Data Sheet
PXE Data Sheet

... Power Distribution PXE Series Intelligent PDUs that give you more control of power and cooling in the data center. • Remote power monitoring and metering of current (amps), voltage, power (kVA, kW) and energy consumption (kWh) ...
H45014650
H45014650

battery power unit
battery power unit

Fluke 40/41 Power Harmonics Analysers
Fluke 40/41 Power Harmonics Analysers

Product data sheet 3RT1033-3AK60 CONTACTOR, AC-3 11 KW/400 V,
Product data sheet 3RT1033-3AK60 CONTACTOR, AC-3 11 KW/400 V,

... SIZE S2, CAGE CLAMP CONNECTION ...
< 1 ... 178 179 180 181 182 183 184 185 186 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report