• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
S280-70-1
S280-70-1

... Recloser Interface (RIF) module to provide isolation for reliable operation. Voltages for metering are connected to the analog board via the connector terminal block, TB-2. A functional block diagram of the Form 6 recloser control is shown in Figure 2. Line current flowing through the recloser is co ...
Data Assessment for Electrical Surge Protection Devices
Data Assessment for Electrical Surge Protection Devices

... guidance has been issued by IEEE and NIST to help homeowners protect their house and its contents. This protection has often been described as being similar to an insurance policy, partly because there is not an NFPA code requirement for SPD installation in residences. Today’s residences often conta ...
Physical Noise Sources
Physical Noise Sources

Introduction to Circuit Protection, Control, and Measurement
Introduction to Circuit Protection, Control, and Measurement

Lecture 9: EM Transmission Lines and Smith Chart
Lecture 9: EM Transmission Lines and Smith Chart

Smart grid implementation in power system Subtitle
Smart grid implementation in power system Subtitle

Power Requirements for Cybex Products
Power Requirements for Cybex Products

... WARNING: U  se only Cybex replacement parts when servicing. Failure to do so could result in personal injury. Cybex will void warranty if non-Cybex replacement parts are used. CAUTION: Place cords away from heat (such as baseboards). Use care to arrange any cord so it doesn’t become an obstacle. G ...
RTM Front Matter Template
RTM Front Matter Template

... advice of, senior technicians in these ratings, this series provides beginners with fundamental electrical and electronic concepts through self-study. The presentation of this series is not oriented to any specific rating structure, but is divided into modules containing related information organize ...
Basic Electricity & Electronics  IT 1011 for
Basic Electricity & Electronics IT 1011 for

KEP Master Spec
KEP Master Spec

... or both sources. The user shall be able to control up to nine loads with independent timing sequences for pre and post transfer delays in either direction of transfer. 10.11. A current based load control feature shall be available to allow the prioritized addition and removal of loads based on the m ...
Technical Description PCM Modules ZM modular
Technical Description PCM Modules ZM modular

5. Nodal analysis
5. Nodal analysis

... Circuit Analysis – A Systematic Approach • We’ve learned several tricks to perform circuit analysis: Single loop circuits, equivalent resistor, superposition etc. • Nodal Analysis is a rather general method that allows you to analyze virtually all the linear circuits via a well defined recipe. ...
SP331 数据资料DataSheet下载
SP331 数据资料DataSheet下载

... compared to older less efficient designs. The charge pump still requires four external capacitors, but uses a four–phase voltage shifting technique to attain symmetrical 10V power supplies. Figure 15(a) shows the waveform found on the positive side of capcitor C2, and Figure 15(b) shows the negative ...
88AP510 Hardware Specifications
88AP510 Hardware Specifications

... • Added pull-up and pull-down information for SPI_2_MOSI and SPI_2_SCK in. • Updated the table with new power rail and MPP information. 7. Revised Table 25, Power Management Unit Interface, on page 50 by adding the PMU_ prefix, updating MPP power rail information, and descriptions. 8. Added in the V ...
Introduction to Technical Mathematics
Introduction to Technical Mathematics

SkyWalker1 and SkyWalker2 Hardware Manual
SkyWalker1 and SkyWalker2 Hardware Manual

MAX5494–MAX5499 10-Bit, Dual, Nonvolatile, Linear-Taper Digital Potentiometers General Description
MAX5494–MAX5499 10-Bit, Dual, Nonvolatile, Linear-Taper Digital Potentiometers General Description

... Note 2: The DNL and INL are measured for the voltage-divider with H_ = VDD and L_ = VSS. The wiper terminal (W_) is unloaded and measured with a high-input-impedance voltmeter. Note 3: The DNL and INL are measured with L_ = VSS = 0. For VDD = 5V, the wiper terminal is driven with a current source of ...
Philbrick`s Polyphemus
Philbrick`s Polyphemus

... specified maximum and minimum values when the controlled variable went beyond those limits. Philbrick accomplished this, as indicated in Figure 3. In Figure 3 the process component might have been as shown in Figure 2(b) where, for example, the voltage T" was a controlled variable. The set point (th ...
Fundamentals for Surge protection
Fundamentals for Surge protection

... operations: IEC 60364-4-44 [5] deals with this. In comparison with IEC 62305, it is based on a shortened risk analysis and uses this as the basis for deriving corresponding measures. In addition to the standards mentioned, if applicable, other legal and country- specific stipulations are also to ...
sc200 Controller
sc200 Controller

... and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate r ...
P7 AC GENERATORS Installation, Servicing, and Maintenance
P7 AC GENERATORS Installation, Servicing, and Maintenance

... the generator output. The module uses generator voltage and output current as inputs and interfaces with the AVR to ensure the necessary flexibility of the generator excitation and hence control of the exported (or imported) kVAr. This allows full closed-loop control of the generator power factor at ...
Application Information for Tuner-Receiver/IRDs
Application Information for Tuner-Receiver/IRDs

... It is only the last of these which need be directly affected by introduction of DiSEqC, and even here the changes are only concerned with re-defining, or adding, a few data-bits used for control purposes, as outlined in the following sections. ...
The RCD Handbook
The RCD Handbook

... winding is used as a sensing coil and is electrically connected to a sensitive relay or solid state switching device, the operation of which triggers the tripping mechanism. When the line and neutral currents are balanced, as in a healthy circuit, they produce equal and opposite magnetic fluxes in t ...
B-05: Rack In/Rack Out Breakers
B-05: Rack In/Rack Out Breakers

... o Follow all Caterpillar facility safety standards when performing this task. o Explosive hazard can result if a breaker is improperly sized or wired. o Electrical hazard exists whenever lock and tag is removed. Stand to the side when opening or closing the breaker. o OSHA regulations require wearin ...
High-Performance Phase-Locked Loop (Rev. B)
High-Performance Phase-Locked Loop (Rev. B)

< 1 ... 45 46 47 48 49 50 51 52 53 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report