FDC10 10 Series of Power Moudules : DC/DC Converter
... TOS xx-xxSM (SMD package) and TOS xx-xxSIL (SIP package) are non-isolated DC/DC Point-of-Load converters that can deliver up to 6A (TOS 06-xxyyy), 10A (TOS 10-xxyyy) or 16A (TOS 16-xxyyy) of output current with an efficiency of up to 94% at 3.3V output voltage. These modules provide precisely regula ...
... TOS xx-xxSM (SMD package) and TOS xx-xxSIL (SIP package) are non-isolated DC/DC Point-of-Load converters that can deliver up to 6A (TOS 06-xxyyy), 10A (TOS 10-xxyyy) or 16A (TOS 16-xxyyy) of output current with an efficiency of up to 94% at 3.3V output voltage. These modules provide precisely regula ...
SPECIFICATION FOR APPROVAL
... 1.1.7.1 83 % min. at nominal input voltage, maximum load and measured at the end of DC cable. ...
... 1.1.7.1 83 % min. at nominal input voltage, maximum load and measured at the end of DC cable. ...
CPT Controller
... detection, monthly monitoring of leaks of 0.2 gph or greater, and annual monitoring for leaks of 0.1 gph or greater. Hourly Leak Detection: This feature provides positive shutdown when a 3-gph or greater leak is detected. The 3-gph leak detection feature replaces the mechanical line-leak detector th ...
... detection, monthly monitoring of leaks of 0.2 gph or greater, and annual monitoring for leaks of 0.1 gph or greater. Hourly Leak Detection: This feature provides positive shutdown when a 3-gph or greater leak is detected. The 3-gph leak detection feature replaces the mechanical line-leak detector th ...
Question Bank on Networks - Prof. Ch. Ganapathy Reddy
... with in the terminal Power absorbed by voltage source is positive if current flows from positive to negative with in the terminal When frequency of the sources are same either DC or AC use superposition theorem to find current and voltage but not power. However when AC sources are there it takes ...
... with in the terminal Power absorbed by voltage source is positive if current flows from positive to negative with in the terminal When frequency of the sources are same either DC or AC use superposition theorem to find current and voltage but not power. However when AC sources are there it takes ...
Truth tables and Resistors ion series and parallel
... of a single resistor that can take the place of a combination ...
... of a single resistor that can take the place of a combination ...
generator (alternator) overhaul
... MOTORS CS SERIES • If the charge indicator light is on in the dash, unplug the connector (which can have up to four wires connected). • Check all fuses, all fusible links, and the charge light indicator bulb. ...
... MOTORS CS SERIES • If the charge indicator light is on in the dash, unplug the connector (which can have up to four wires connected). • Check all fuses, all fusible links, and the charge light indicator bulb. ...
FR-A520-0.4K to 55K(-NA) FR-A540-0.4K to 55K(-NA
... The load used should be a three-phase induction motor only. Connection of any other electrical equipment to the inverter output may damage the equipment. The electronic overcurrent protection does not guarantee protection of the motor from overheating. Do not use a magnetic contactor on the inverter ...
... The load used should be a three-phase induction motor only. Connection of any other electrical equipment to the inverter output may damage the equipment. The electronic overcurrent protection does not guarantee protection of the motor from overheating. Do not use a magnetic contactor on the inverter ...
Stax SRS-4170 Earspeaker System Reviewed
... the venerable Lambda Signature Nova and Lambda Nova Classic. The SR-407 even shares the same headband, driver yokes, earpads, and outer casing as the earlier models, but inside, it's very different. Since first introduced in 1979, the Lambda series has had four revisions. The original Lambda signat ...
... the venerable Lambda Signature Nova and Lambda Nova Classic. The SR-407 even shares the same headband, driver yokes, earpads, and outer casing as the earlier models, but inside, it's very different. Since first introduced in 1979, the Lambda series has had four revisions. The original Lambda signat ...
MAX13046E/MAX13047E Single- and Dual-Bidirectional Low-Level Translator General Description
... either direction (VL↔VCC) on any single data line. The MAX13046E/MAX13047E accept VL from +1.1V to the minimum of either +3.6V or (VCC + 0.3V), and VCC from +1.65V to +5.5V, making these devices ideal for data transfer between low-voltage ASICs/PLDs and higher voltage systems. The MAX13046E/MAX13047 ...
... either direction (VL↔VCC) on any single data line. The MAX13046E/MAX13047E accept VL from +1.1V to the minimum of either +3.6V or (VCC + 0.3V), and VCC from +1.65V to +5.5V, making these devices ideal for data transfer between low-voltage ASICs/PLDs and higher voltage systems. The MAX13046E/MAX13047 ...
C21 Dimming System
... The regulation shall adjust for both RMS voltage and frequency changes of the incoming AC wave form. Regulation shall maintain the desired output voltage +/.5V volt for the entire operation range (90 - 264 VAC). The regulation shall compensate for variations of the AC waveform on a dimmer-by-dimmer ...
... The regulation shall adjust for both RMS voltage and frequency changes of the incoming AC wave form. Regulation shall maintain the desired output voltage +/.5V volt for the entire operation range (90 - 264 VAC). The regulation shall compensate for variations of the AC waveform on a dimmer-by-dimmer ...
Methods for Probabilistic Fault Diagnosis
... hybrid, complex setting is an important topic for on-going research. In this paper, we develop methods for hybrid diagnosis by means of discrete probabilistic models (Bayesian networks and arithmetic circuits), and specifically develop novel techniques for handling abrupt continuous (or parametric) ...
... hybrid, complex setting is an important topic for on-going research. In this paper, we develop methods for hybrid diagnosis by means of discrete probabilistic models (Bayesian networks and arithmetic circuits), and specifically develop novel techniques for handling abrupt continuous (or parametric) ...
SERVICE MANUAL GPIB DC Power Supplies Agilent Series 654xA
... • If this instrument is to be energized via an auto-transformer (for voltage change), make sure the common terminal is connected to the earth terminal of the power source. • Any interruption of the protective (grounding) conductor (inside or outside the instrument), or disconnecting of the protectiv ...
... • If this instrument is to be energized via an auto-transformer (for voltage change), make sure the common terminal is connected to the earth terminal of the power source. • Any interruption of the protective (grounding) conductor (inside or outside the instrument), or disconnecting of the protectiv ...
“Remedial Action Scheme” Definition Development
... and/or in addition to the isolation of faulted components to maintain system reliability. Such action may include changes in demand, generation (MW and Mvar), or system configuration to maintain system stability, acceptable voltage, or power flows. An SPS does not include (a) underfrequency or und ...
... and/or in addition to the isolation of faulted components to maintain system reliability. Such action may include changes in demand, generation (MW and Mvar), or system configuration to maintain system stability, acceptable voltage, or power flows. An SPS does not include (a) underfrequency or und ...
74AVCH20T245 1. General description 20-bit dual supply translating transceiver with configurable
... HIGH on a 1DIR allows transmission from 1An to 1Bn and a LOW on 1DIR allows transmission from 1Bn to 1An. A HIGH on nOE causes the outputs to assume a HIGH impedance OFF-state. The device is fully specified for partial power-down applications using IOFF. The IOFF circuitry disables the output, preve ...
... HIGH on a 1DIR allows transmission from 1An to 1Bn and a LOW on 1DIR allows transmission from 1Bn to 1An. A HIGH on nOE causes the outputs to assume a HIGH impedance OFF-state. The device is fully specified for partial power-down applications using IOFF. The IOFF circuitry disables the output, preve ...
74AVCH8T245 1. General description 8-bit dual supply translating transceiver with configurable
... referenced to VCC(B). A HIGH on DIR allows transmission from An to Bn and a LOW on DIR allows transmission from Bn to An. The output enable input (OE) can be used to disable the outputs so the buses are effectively isolated. The device is fully specified for partial power-down applications using IOF ...
... referenced to VCC(B). A HIGH on DIR allows transmission from An to Bn and a LOW on DIR allows transmission from Bn to An. The output enable input (OE) can be used to disable the outputs so the buses are effectively isolated. The device is fully specified for partial power-down applications using IOF ...
Guideform Specification
... a normal source failure and delay the operation of the transfer switch for a user-specified time period. Controller shall be capable of being programmed for an extended time delay up to 259 minutes if an external power supply is provided to the ATS control. All ATS supplied shall have wiring and pro ...
... a normal source failure and delay the operation of the transfer switch for a user-specified time period. Controller shall be capable of being programmed for an extended time delay up to 259 minutes if an external power supply is provided to the ATS control. All ATS supplied shall have wiring and pro ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.