• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SIMODRIVE 611 Drive Converter
SIMODRIVE 611 Drive Converter

... The following limitations must be observed when the system is subject to a high voltage test: 1. Power down the equipment so that it is in a no–voltage condition. 2. Withdraw the overvoltage module to prevent the voltage limiting responding. 3. Disconnect the line filter to prevent dips in the test ...
EQ-SWT 1e - LSK Electrics Oy
EQ-SWT 1e - LSK Electrics Oy

... The movingāĆācoil panel meters PQ 48/72/96/144 K (K series) housed in moulded thermoplastic cases are suitable for the measurement of DC currents and voltages. The instruments are suitable to be mounted in switchboards, control panels, machine tool consoles and mosaic panels. The bezel, the glass wi ...
PA-800 Series Hardware Reference
PA-800 Series Hardware Reference

... These ports are for network traffic and their speed varies depending on your  firewall and configuration. PA‐820 Firewalls Four 1Gbps SFP ports; you cannot reconfigure these ports. PA‐850 Firewalls Four 1Gbps SFP ports or four 10Gbps SFP+ ports (default); you can specify  which you want to use but y ...
MAX6361–MAX6364 SOT23, Low-Power µP Supervisory Circuits with Battery Backup General Description
MAX6361–MAX6364 SOT23, Low-Power µP Supervisory Circuits with Battery Backup General Description

... complexity and number of components required for power-supply monitoring and battery control functions in microprocessor (µP) systems. The circuits significantly improve system reliability and accuracy compared to that obtainable with separate ICs or discrete components. Their functions include µP r ...
The effect of a strip-type third electrode of a wire
The effect of a strip-type third electrode of a wire

40in Gas Furnace Ser..
40in Gas Furnace Ser..

... the IFC. If the furnace is a two stage model, there will be one pin for voltage out to both switches and then two pins to receive the 24 volt potential back at the IFC board (fig. 6). When a call for heat is received by the IFC, the IFC sends 24 volts out to the vent pressure safety switch. If the s ...
Winding insulation and maintenance
Winding insulation and maintenance

interactive
interactive

... It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safet ...
System 3 Manual
System 3 Manual

A Guide To Diagnostic Insulation Testing Above 1 kV
A Guide To Diagnostic Insulation Testing Above 1 kV

... This is particularly appropriate now when we consider that large parts of the electrical network in the USA and Europe were installed in the 1950s in a burst of postwar investment. Some equipment is approaching the end of its design life, while some has already exceeded it but is still operating sat ...
MICROMASTER 420 0.12 kW - 11 kW Operating Instructions Issue 10/06
MICROMASTER 420 0.12 kW - 11 kW Operating Instructions Issue 10/06

Solenoid Basics - DSF Technologies
Solenoid Basics - DSF Technologies

... Let’s assume your application requires a maximum pull force of 7 pounds at a 1 inch stroke. After looking at the “pull vs. stroke” graph, the solenoid you’re considering (Model 1502) has a 9 pound pull force at 1 inch stroke. We’ll represent this pull force with the letters (Fo). You know the soleno ...
MAX6400–MAX6405 µP Supervisory Circuits in 4-Bump (2 2) Chip-Scale Package
MAX6400–MAX6405 µP Supervisory Circuits in 4-Bump (2 2) Chip-Scale Package

... A microprocessor’s (µP’s) reset input starts the µP in a known state. These µP supervisory circuits assert reset to prevent code execution errors during power-up, power-down, or brownout conditions. RESET is guaranteed to be a logic low for VCC down to 1V. Once VCC exceeds the reset threshold, an in ...
please note that catalog is being updated!
please note that catalog is being updated!

... Fig. 1. The matrix is nonblocking, but not full fan-out. Nonblocking means that any input can be connected to any output without interrupting a previously set path. When a matrix is not full fanout, an input may be switched to only one output. Matrix configurations from 2x2 to 8x8 or larger are poss ...
- Aplisens
- Aplisens

... failure to maintain the device in a suitable technical condition, or use of the device other than for its intended purpose. Installation should be carried out by qualified staff having the required authorizations to install electrical and pressure-measuring devices. The installer is responsible for ...
Evaluation  of Aging  and Environmental  Qualification
Evaluation of Aging and Environmental Qualification

... also susceptible to aging degradation and However, other classes of safety-related electrical equipment are practices. Power cables are among should be studied to address issues related to their current qualification the equipment identified for additional study. or more metallic conductors insulate ...
week2_Introduction to tuned circuits&filter
week2_Introduction to tuned circuits&filter

...  Zero is a term used to refer to a frequency at which there is zero impedance in the circuit.  Envelope delay or time delay is the time it takes for a specific point on an input waveform to pass through the filter.  Roll-off or attenuation rate is the rate of change of amplitude with frequency in ...
Mitsubishi FR-E520, FR-E540, FR-E520S, FR-E510W
Mitsubishi FR-E520, FR-E540, FR-E520S, FR-E510W

... indicator lamp is off, wait for at least 10 minutes after the power supply has been switched off, and check that there are no residual voltage using a tester or the like. The capacitor is charged with high voltage for some time after power off and it is dangerous. z This inverter must be earthed (gr ...
User Guide - Eurotherm
User Guide - Eurotherm

14-Output Clock Generator AD9516-5  FEATURES
14-Output Clock Generator AD9516-5 FEATURES

... The AD9516-5 is available in a 64-lead LFCSP and can be operated from a single 3.3 V supply. An external VCO, which requires an extended voltage range, can be accommodated by connecting the charge pump supply (VCP) to 5.5 V. A separate LVPECL power supply can be from 2.375 V to 3.6 V (nominal). The ...
icap/4rx getting started
icap/4rx getting started

... Selecting Parts or Symbols ............................................................................................... 23 Customizing the SpiceNet Toolbar .................................................................................... 24 Editing a Schematic ................................. ...
Solid-State Sensing, a Professional Course
Solid-State Sensing, a Professional Course

ABB Comp-AC User`s Manual ACS 400 AC Drives for Speed Control
ABB Comp-AC User`s Manual ACS 400 AC Drives for Speed Control

A. General - Rules and standards
A. General - Rules and standards

... independent synchronising device for each generator has been added for clarification. — H500 (previous H400): Equipment requiring emergency stop has been updated in line with SOLAS. Requirement for separation of control cables and control circuits for duplicated equipment has been added. — I206 This ...
www.geca.ac.in
www.geca.ac.in

... of incident radiation, typically visible or infrared light, which heats the hot junctions, while the cold junctions are on a heat sink.  Manufacturing:- Thermocouples can generally be used in the testing of prototype ...
< 1 ... 26 27 28 29 30 31 32 33 34 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report