• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
- EasyEDA
- EasyEDA

... Output clamp voltage in response to regulator output voltage being forced to rise above normal set voltage by placing 1k in parallel with R7 (Rbot1) Rbot1//1k (Ohms) Input voltage (V) ...
Digital Electronics 13.4b
Digital Electronics 13.4b

Oct - Directorate General of Shipping
Oct - Directorate General of Shipping

... delta cases. Draw vector diagram. Three impedances Z = 5 + j 4 are connected in the form of a delta to the three loads of a balanced 3-phase circuit. The line voltage is 120 volts. Find (a) the phase current, (b) power factor, (c) the volt-ampere in the circuit. 9. A shunt motor runs at 900 rev/min ...
DC-voltage doubler reaches 96% power efficiency
DC-voltage doubler reaches 96% power efficiency

... protective subcircuit, is RL≤m2×(α/(1−α))×Rp, where the multiplication factor m=(VOUT/VIN) and α is a fraction of VOUT, at which the soft start turns off. For m=2, α=0.8, and Rp=10Ω, RL is 160Ω. Thus, loads of 160Ω or less will overload the circuit if you connect them to the circuit’s output before ...
Proposed System
Proposed System

... CIRCUIT DIAGRAM ...
150LECTURE20 POWER SUPPLIES Lecture Notes Page
150LECTURE20 POWER SUPPLIES Lecture Notes Page

... definition is the ratio between watts and volt-amps. A PFC pre-regulator controls input AC current so that it is in phase with mains AC voltage and its waveform repeats the input voltage waveform. Without this, the input current would be delivered to the SMPS in short high peak pulses, which have a ...
High Voltage Power Supplies
High Voltage Power Supplies

... conversion products such as high voltage power supplies, low voltage power supplies, DC-DC converters, and power systems products. Rantec’s products serve the medical, analytical, industrial, aviation, defense, and communications industries. ...
BDS-MF Generator
BDS-MF Generator

Power-aware Computing slides
Power-aware Computing slides

... Power-aware Computing ...
(with corrections indicated in lecture) MSWord file, due session 22
(with corrections indicated in lecture) MSWord file, due session 22

... 2. Find and plot one cycle of the dc current that accompanies a three-level space vector PWM that yields a vector of 0.50 Vdc / 40° Volts. The load current is 200 Amps with a power factor of 1.00. A number for Vdc is not necessary, but if you want one, make one up and declare it. ...
HVLED805 – one-chip solution for LED driving
HVLED805 – one-chip solution for LED driving

DCA2000 - 2 – 60, 34
DCA2000 - 2 – 60, 34

... Behlman’s DCA2000 series of COTS power supplies are highly reliable, switch mode units built for high-end industrial or MIL applications. The DCA series accepts three phase “Y” or delta inputs and can supply a variety of DC from 3.3 VDC to 100 VDC outputs. Output power levels range from 1500 W to 30 ...
HX11RB External Voltage Reference
HX11RB External Voltage Reference

0496755001195066370
0496755001195066370

DC1664 - LTC3109EUF Evaluation Kit Quick Start Guide
DC1664 - LTC3109EUF Evaluation Kit Quick Start Guide

... the average source power integrated over the accumulation time between bursts. The Demonstration Circuit has been set up with a storage capacitor that makes it easy to evaluate the general functionality of the circuit. The lower value capacitor allows for a fast charge time but limits the pulsed ene ...
ROHM Stepper Motor Drivers
ROHM Stepper Motor Drivers

... infrastructure , factory automation equipment, industrial machinery, and other applications that normally operate at 48V and higher, improving system reliability. 2. The industry’s highest efficiency The industry’s highest power conversion efficiency in the 76V DC/DC converter class has been achieve ...
Datasheet - DE-SW0XX
Datasheet - DE-SW0XX

... If the current limit has been considerably exceeded or if the device is overheated the product will gradually reduce the output voltage in an attempt to reduce the load on the device. Once the extra load is removed or the temperature is brought down, the desired output voltage will be restored. It i ...
V = 40 + j35 volts I = 6 + j3 amps The above is the pd across a circuit
V = 40 + j35 volts I = 6 + j3 amps The above is the pd across a circuit

Project : Switched capacitor voltage regulator
Project : Switched capacitor voltage regulator

Switched-mode power supply charger
Switched-mode power supply charger

Vacuum Tube Amplifier (1).
Vacuum Tube Amplifier (1).

... with vacuum tubes and vacuum tube amplifiers  As seniors in electrical engineering and having had an experience with solid state transistors in the classroom and laboratory, we want to explore an alternative way of electrical signal amplification ...
ETEE3212 Spring 2006 Test #1
ETEE3212 Spring 2006 Test #1

... b. Differential mode voltage gain and common mode voltage gain for the total system c. Differential mode input voltage (vdi) for maximum output ...
Document
Document

Test Procedure for the NCP1083WIRGEVB Evaluation Board
Test Procedure for the NCP1083WIRGEVB Evaluation Board

... 5) Measure the output voltage to be 12V and that ripple or noise on the output is within the specification. 6) DC/DC converter stability can be briefly checked by switching on and of repeatedly the load and monitor the voltage transients on an oscilloscope (there should be no oscillation on the outp ...
Quiz 3 Solutions
Quiz 3 Solutions

< 1 ... 2635 2636 2637 2638 2639 2640 2641 2642 2643 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.