• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Response-Based, Feedforward Wide-Area Control
Response-Based, Feedforward Wide-Area Control

AN4075
AN4075

Battery Charging using Constant Current with Electronic Loads with
Battery Charging using Constant Current with Electronic Loads with

... is high, as the battery starts charging up the voltage shifts from the battery being low to the battery being higher and dropping less voltage across the electronic load. At some point you want to stop the electronic load from charging the battery any more. Since the battery drops more and more vol ...
PP BCD TT 25/100 (/FM)
PP BCD TT 25/100 (/FM)

... allows you to achieve a high-level discharge capacity without needing blow-out vents. This saves you from keeping the safety distance to adjoining electrical components usually necessary to avoid unwanted electric arcs and fire hazardous. As there is no risk of leakage currents, this SPD can also be ...
ENGR 311 - Bipolar Junction Transistors
ENGR 311 - Bipolar Junction Transistors

... Note: the collector current is not due to forward conduction of the base-collector diode; that diode is reverse-biased. Just think of it as “transistor action.” Property 3 gives the transistor its usefulness: a small current flowing into the base controls a much larger current flowing into the colle ...
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)

... dissipation on the switching devices will give rise to highly efficient power electronic system. For example, if a semiconductor device operates in a linear mode such as in power amplifiers of in linear regulators, it is expected that some amount of energy will be lost in the power circuit before it ...
Circuits with Transistors Contents 1 Transistors
Circuits with Transistors Contents 1 Transistors

... on the other hand, if we need to amplify the whole cycle we need to build a set up with two transistors in the so called push-pull amplifier. In figure 10 is shown how it works a class B common collector a mplifier. As it has been said the operational Q-point is at blockage, so while the signal is i ...
G656/G657 - Global Mixed
G656/G657 - Global Mixed

... Externally Programmable Time Delay Generator 27µA Supply Current at VCC=3.3V Guaranteed Reset Valid to VCC = 0.8V TSOT-23-5 Packages 2% Threshold Accuracy ...
appendix 1 - mathapps.net
appendix 1 - mathapps.net

... The four figures below illustrate how the area is zero under a product of two different frequency sinusoids and not zero (area = T/2 =  ) when the frequencies are the same. ...
ADP2291 数据手册DataSheet 下载
ADP2291 数据手册DataSheet 下载

... ADP2291 also features automatic reverse isolation, which does not require an additional blocking diode. ...
Low Current Measurements - Techni-Tool
Low Current Measurements - Techni-Tool

... which depends both on the electrometer input capacitance and the connecting cable capacitance. Thus, for high resistance measurements, even a small amount of cable capacitance can result in very long rise times. For example, an input capacitance of 1,000pF (including the input cable) and a resistanc ...
Electronics Class 2
Electronics Class 2

... • E = I x R : Voltage = Current x Resistance • Volts is measure in VOLTS, current is measured in AMPS, and resistance is measured in OHMS. • 1 AMP, going through 1 OHM of resistance, generates a voltage drop of 1 VOLT. • 1 V = 1 A x 1 Ω. ...
Pro200 OM SSN.QXD
Pro200 OM SSN.QXD

... not covered by any warranty. See the Connecting Power section in Chapter 5 for more information on voltage. Note — Always turn off and disconnect the amplifier from mains voltage before making audio connections. As an extra precaution, have the attenuators turned down during power-up. Although Pro 2 ...
THIS DOCUMENT IS FOR MAINTENANCE PURPOSES ONLY AND IS NOT
THIS DOCUMENT IS FOR MAINTENANCE PURPOSES ONLY AND IS NOT

... fv. fr or fv leading: positive pulses with respect to the bias point VBIAS fv , fr or fr leading: negative pulses with respect to the bias point VBIAS fv = fr and phase error within PDA window: high impedance. ...
Compact Device Modelling for System Simulation - Mos-AK
Compact Device Modelling for System Simulation - Mos-AK

Adaptive control of power electronic drives for servomechanical
Adaptive control of power electronic drives for servomechanical

... One power electronic drive, for example, is a unidirectional power transfer coupling that draws power from the ac utility through a high power factor pre-regulator. Power is transferred to the load through a half-bridge inverter that energizes a separable transformer or inductive coupling. Another d ...
Evaluates:  MAX3802 MAX3802 Evaluation Kit General Description Features
Evaluates: MAX3802 MAX3802 Evaluation Kit General Description Features

... 1) Connect a differential input signal (600mVP-P differential input amplitude) to one of the cable driver inputs at SMA edge connectors J9 (DIN1-) and J10 ...
This is a report of ACS800 Island Converter on site measurements
This is a report of ACS800 Island Converter on site measurements

... harmonics and asymmetricity caused by load. The spectrum of voltage distortion in frequency range 0 – 2 kHz is typical to used modulation method and line filter. There was no indication of network resonance in frequency range 2.5 – 9 kHz. The power quality measurements show that power quality in thi ...
MAX125/MAX126 2x4-Channel, Simultaneous-Sampling 14-Bit DAS General Description
MAX125/MAX126 2x4-Channel, Simultaneous-Sampling 14-Bit DAS General Description

... per CONVST pulse. In the default mode, one T/H output (CH1A) is converted. An interrupt signal (INT) is provided after the last conversion is complete. Convert two, three, or four channels by reprogramming the MAX125/MAX126 through the bidirectional parallel interface. Once programmed, the MAX125/MA ...
series circuit. - GZ @ Science Class Online
series circuit. - GZ @ Science Class Online

... The ‘voltage’ of an electrical supply is a measure of the energy it can transfer from an electrical supply elsewhere An electric current won't flow through a circuit unless there's a source of energy like a battery or mains electricity to push the electric charges along through the wire. 'Voltage' ...
Microcontroller Systems ELET 3232 Topic 22: Load Analysis 1
Microcontroller Systems ELET 3232 Topic 22: Load Analysis 1

... volts is not sufficient to meet the CMOS input high VIH = 3.0 volts. Since the LSTTL VOL is 0.4 volts and the CMOS VIL is 2.0 volts, the CMOS input low A pull-up resistor is required to allow the voltage is compatible with the LSTTL low LS-TTL output to go to a higher voltage: output voltage. VIH + ...
RURG5060_F085 50A, 600V Ultrafast Rectifier RURG5060_F085  50A, 600V Features
RURG5060_F085 50A, 600V Ultrafast Rectifier RURG5060_F085 50A, 600V Features

... The RURG5060_F085 is an ultrafast diode with soft recovery characteristics (trr< 90ns). It has low forward voltage drop and is silicon nitride passivated ionimplanted epitaxial planar construction. This device is intended for use as a freewheeling/clamping diode and rectifier in a variety of switchi ...
(MR15 Regulations)II Mid Examination
(MR15 Regulations)II Mid Examination

... 26. Bandwidth is defined as the range of frequencies within which the power delivered to R is a) equal to half power at resonance b) less than half the power at resonance c) greater than half power at resonance d) None. 27 . When a pure Lc parallel circuit is in resonance, the circuit condition can ...
Chapter 4
Chapter 4

... 1. Emphasize that when selecting a computer case, motherboard, and power supply, choose a design that fits its intended use. 2. Use Table 2-1 to illustrate the current and better-known form factors. 3. Introduce and describe the Advanced Technology Extended (ATX) form factor. a. Use Figure 2-2 to il ...
News Musikmesse Frankfurt 2008
News Musikmesse Frankfurt 2008

... switch works as an octave switch as the default 1.00V are added or subtracted to the output voltage according to the switch position. An internal jumper can be used to connect the non-inverted or inverted output to the CV line of the A-100 bus. That way the module can used to control several VCOs th ...
< 1 ... 1425 1426 1427 1428 1429 1430 1431 1432 1433 ... 2646 >

Switched-mode power supply



A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report