VJ1000 - Klompenboer
... The power supply, accessible via the rear panel, has been designed to be both rugged and at the same time simple to maintain, allowing easy access to every component thus easing repair work. The power supply features a PI filter after the rectifying stage which attenuates spurious components. Two fu ...
... The power supply, accessible via the rear panel, has been designed to be both rugged and at the same time simple to maintain, allowing easy access to every component thus easing repair work. The power supply features a PI filter after the rectifying stage which attenuates spurious components. Two fu ...
ENERGY CONVERSION ONE
... • Solidly grounding the neutrals of windings specially primary winding, this connection provide a path for 3rd harmonic current flow, produced and do not let build up of large 3rd voltages . Also provides a return path for any current imbalances in load • Adding a third winding (tertiary) connected ...
... • Solidly grounding the neutrals of windings specially primary winding, this connection provide a path for 3rd harmonic current flow, produced and do not let build up of large 3rd voltages . Also provides a return path for any current imbalances in load • Adding a third winding (tertiary) connected ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
... II. TCSC (THYRISTOR CONTROLLED SERIES CAPACITOR) Series Capacitors are installed in series with a transmission line, which means that all the equipment has to be installed on a fully insulated platform. Significant device from the group FACTS is a TCSC, which finds application in solving many proble ...
... II. TCSC (THYRISTOR CONTROLLED SERIES CAPACITOR) Series Capacitors are installed in series with a transmission line, which means that all the equipment has to be installed on a fully insulated platform. Significant device from the group FACTS is a TCSC, which finds application in solving many proble ...
INSTALLATION AND OPERATION
... Install as near to vertical as possible. For best accuracy operation within 2 ½% of vertical is desirable. ...
... Install as near to vertical as possible. For best accuracy operation within 2 ½% of vertical is desirable. ...
SN75ALS161 数据资料 dataSheet 下载
... Transfer general-purpose interface bus transceivers are high-speed, advanced low-power Schottky-process devices designed to provide the bus-management and data-transfer signals between operating units of a single-controller instrumentation system. When combined with the SN75ALS160 octal bus transcei ...
... Transfer general-purpose interface bus transceivers are high-speed, advanced low-power Schottky-process devices designed to provide the bus-management and data-transfer signals between operating units of a single-controller instrumentation system. When combined with the SN75ALS160 octal bus transcei ...
AC Circuits
... The time behavior and the state-space trajectory can be strobed once every driving cycle to reproduce a sequence of points whose values are like those of successive iterations of a map. To do this set up one function generator as a pulse generator, synchronized with the driving generator, and drivin ...
... The time behavior and the state-space trajectory can be strobed once every driving cycle to reproduce a sequence of points whose values are like those of successive iterations of a map. To do this set up one function generator as a pulse generator, synchronized with the driving generator, and drivin ...
VP60 5/3 proportional directional control valve direct acting spool
... the spool, are lowest in this orientation). Voltage supply: The VP60 is rated for a 24 V d.c. voltage supplied between Ub and GND. Reversing the polarity of the supply will not damage the electronics because they have built-in protection. The valve will not work, however. The actuator system (= spoo ...
... the spool, are lowest in this orientation). Voltage supply: The VP60 is rated for a 24 V d.c. voltage supplied between Ub and GND. Reversing the polarity of the supply will not damage the electronics because they have built-in protection. The valve will not work, however. The actuator system (= spoo ...
PRODUCT OVERVIEW FOR MEDICAL APPLICATIONS
... Flexible High Voltage Supplies up to VPP-VNN = 200V DC to 10MHz Analog Signal Frequency Low Quiescent Power Dissipation (< 1μA Typical) Output Switch On-Resistance Typically 20Ω TTL I/Os for 3.3V Interface ...
... Flexible High Voltage Supplies up to VPP-VNN = 200V DC to 10MHz Analog Signal Frequency Low Quiescent Power Dissipation (< 1μA Typical) Output Switch On-Resistance Typically 20Ω TTL I/Os for 3.3V Interface ...
TPS54350 数据资料 dataSheet 下载
... These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. ...
... These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. ...
AD558: 英文产品数据手册下载
... output ranges, 0 V to 2.56 V and 0 V to 10 V. The amplifier output stage is an NPN transistor with passive pull-down for zero-based output capability with a single power supply. The internal precision voltage reference is of the patented bandgap type. This design produces a reference voltage of 1.2 ...
... output ranges, 0 V to 2.56 V and 0 V to 10 V. The amplifier output stage is an NPN transistor with passive pull-down for zero-based output capability with a single power supply. The internal precision voltage reference is of the patented bandgap type. This design produces a reference voltage of 1.2 ...
Signal Isolation
... It is our objective to deliver the most reliable isolators on the market and that this reliability shall hold true for all your applications - even the harshest of them, as reliability can be directly converted into cost-savings. How much does an hour’s downtime in your process cost? And not least, ...
... It is our objective to deliver the most reliable isolators on the market and that this reliability shall hold true for all your applications - even the harshest of them, as reliability can be directly converted into cost-savings. How much does an hour’s downtime in your process cost? And not least, ...
EE 174 Spring 2016
... These values exceed the maximum values allowed. To attain large input resistance with moderate resistances for an inverting amplifier, we cascade a voltage follower with an inverter. To achieve the desired gain = - 10. Choose R1 = 1 kΩ R2 = 10 kΩ. ...
... These values exceed the maximum values allowed. To attain large input resistance with moderate resistances for an inverting amplifier, we cascade a voltage follower with an inverter. To achieve the desired gain = - 10. Choose R1 = 1 kΩ R2 = 10 kΩ. ...
Exp_9_Spring13
... (A/D converter or ADC). A set of N bits has 2N possible different values. If you try to represent an analog voltage by 7 bits, your uncertainty will be about 1%, since there are 2 7 = 128 possible combinations of 7 bits. For higher accuracy you need more bits. The corresponding device that can conve ...
... (A/D converter or ADC). A set of N bits has 2N possible different values. If you try to represent an analog voltage by 7 bits, your uncertainty will be about 1%, since there are 2 7 = 128 possible combinations of 7 bits. For higher accuracy you need more bits. The corresponding device that can conve ...
Review of exponential charging and discharging in RC Circuits
... about constant, as once the voltage gets past VZK, the depletion layer does not really increase—the current increases dramatically (also known as avalanche current). As the reverse voltage is increased, there will be a limit to the current flow: reverse saturation current A Zener diode is used t ...
... about constant, as once the voltage gets past VZK, the depletion layer does not really increase—the current increases dramatically (also known as avalanche current). As the reverse voltage is increased, there will be a limit to the current flow: reverse saturation current A Zener diode is used t ...
Linköping University Post Print Power consumption of analog circuits: a tutorial
... that the drain capacitance, Cd , is somewhat lower than Cg , but follows Cg with changing transistor size (width; we assume length constant). In the same time we expect that the drain capacitance must be smaller than CL , as it is a part of CL . In conclusion, we expect that Cg must be smaller than ...
... that the drain capacitance, Cd , is somewhat lower than Cg , but follows Cg with changing transistor size (width; we assume length constant). In the same time we expect that the drain capacitance must be smaller than CL , as it is a part of CL . In conclusion, we expect that Cg must be smaller than ...
Switched-mode power supply
A switched-mode power supply (switching-mode power supply, switch-mode power supply, SMPS, or switcher) is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently. Like other power supplies, an SMPS transfers power from a source, like mains power, to a load, such as a personal computer, while converting voltage and current characteristics. Unlike a linear power supply, the pass transistor of a switching-mode supply continually switches between low-dissipation, full-on and full-off states, and spends very little time in the high dissipation transitions, which minimizes wasted energy. Ideally, a switched-mode power supply dissipates no power. Voltage regulation is achieved by varying the ratio of on-to-off time. In contrast, a linear power supply regulates the output voltage by continually dissipating power in the pass transistor. This higher power conversion efficiency is an important advantage of a switched-mode power supply. Switched-mode power supplies may also be substantially smaller and lighter than a linear supply due to the smaller transformer size and weight.Switching regulators are used as replacements for linear regulators when higher efficiency, smaller size or lighter weight are required. They are, however, more complicated; their switching currents can cause electrical noise problems if not carefully suppressed, and simple designs may have a poor power factor.