Variable speed drives Altivar 312
... for your machine. The oscilloscope function is extremely useful when making adjustments. Multi-Loader configuration tool The configurations of several drives are stored on a standard SD memory card. Simply load it directly into your PC or insert into the Multi-Loader, which can be used as a card rea ...
... for your machine. The oscilloscope function is extremely useful when making adjustments. Multi-Loader configuration tool The configurations of several drives are stored on a standard SD memory card. Simply load it directly into your PC or insert into the Multi-Loader, which can be used as a card rea ...
Adapting KMS for Custom Hardware
... Which means Iphase is 8.008 A when VADC is 3.3 V. The circuits and analysis are identical on the HVP-MC3PH. The FRDM-MC-LVPMSM uses the current sensing circuit shown in Figure 7. ...
... Which means Iphase is 8.008 A when VADC is 3.3 V. The circuits and analysis are identical on the HVP-MC3PH. The FRDM-MC-LVPMSM uses the current sensing circuit shown in Figure 7. ...
WJ200 Series Inverter Instruction Manual
... HIGH VOLTAGE:Hazard of electrical shock. Never touch the naked PCB ...
... HIGH VOLTAGE:Hazard of electrical shock. Never touch the naked PCB ...
pletely - NAPA Echlin
... NAPA® Belden® Ignition Wire Set NAPA® Belden® Edge Premium Spark Plug Wires come ready for installation straight out of the box. New enhancement upgrades like factory installed wire clips, trays and protective loom keep wires sorted individually for quicker, easier installation, while giving improve ...
... NAPA® Belden® Ignition Wire Set NAPA® Belden® Edge Premium Spark Plug Wires come ready for installation straight out of the box. New enhancement upgrades like factory installed wire clips, trays and protective loom keep wires sorted individually for quicker, easier installation, while giving improve ...
Intel® Xeon® Processor 7400 Series Datasheet
... Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whats ...
... Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whats ...
Electronic Ballasts - Lighting Research Center
... Choice of Frequency for Electronic Ballasts A fluorescent lamp’s efficacy relative to 60-Hz operation increases rapidly when the operating frequency changes from 1 kHz to approximately 20 kHz, then increases much more gradually beyond 20 kHz. However, electromagnetic interference (EMI) increases wit ...
... Choice of Frequency for Electronic Ballasts A fluorescent lamp’s efficacy relative to 60-Hz operation increases rapidly when the operating frequency changes from 1 kHz to approximately 20 kHz, then increases much more gradually beyond 20 kHz. However, electromagnetic interference (EMI) increases wit ...
NEM Interconnection Handbook
... A generating facility may not be operated in parallel with SCE’s Distribution System UNTIL WRITTEN PERMISSION TO OPERATE IS GRANTED BY SCE, as required in Electric Rule 21 (PDF). Unauthorized operation may be dangerous and may result in injury to persons and/or may cause damage to equipment and/or p ...
... A generating facility may not be operated in parallel with SCE’s Distribution System UNTIL WRITTEN PERMISSION TO OPERATE IS GRANTED BY SCE, as required in Electric Rule 21 (PDF). Unauthorized operation may be dangerous and may result in injury to persons and/or may cause damage to equipment and/or p ...
20 - 80 kVA UPS User`s and Installation Manual
... problems associated with utility power of poor quality, or a complete loss of power. Sensitive electrical equipment needs protection from electrical interference. Interference from outside the facility (such as lightning, power company accidents and radio transmissions) and interference from inside ...
... problems associated with utility power of poor quality, or a complete loss of power. Sensitive electrical equipment needs protection from electrical interference. Interference from outside the facility (such as lightning, power company accidents and radio transmissions) and interference from inside ...
PowerPoint Presentation - StaticControl.com
... • Refers to voltage being induced into the board or component by contact, resulting in current transfer through the component or board. ...
... • Refers to voltage being induced into the board or component by contact, resulting in current transfer through the component or board. ...
Reviewer 2 - Propeller`s Journal
... 77. On AC vessels, which of the following statements represents the most difficult problem involved in obtaining a DC potential suitable for use by computer components? a. Step – down transformer is always required b. Vessel vibration affect the voltage source c. The voltage must be rectified and m ...
... 77. On AC vessels, which of the following statements represents the most difficult problem involved in obtaining a DC potential suitable for use by computer components? a. Step – down transformer is always required b. Vessel vibration affect the voltage source c. The voltage must be rectified and m ...
R-series - Dynamic Controls
... performed using a controlled programming tool available only to authorised personnel. The product is not user serviceable. Specialised tools are necessary for the repair of any component. Do not install, maintain or operate this equipment without reading, understanding and following this manual – in ...
... performed using a controlled programming tool available only to authorised personnel. The product is not user serviceable. Specialised tools are necessary for the repair of any component. Do not install, maintain or operate this equipment without reading, understanding and following this manual – in ...
4017, 4022
... These counters are cleared to their zero count by a logical “1” on their reset line. These counters are advanced on the positive edge of the clock signal when the clock enable signal is in the logical “0” state. The configuration of the CD4017BC and CD4022BC permits medium speed operation and assure ...
... These counters are cleared to their zero count by a logical “1” on their reset line. These counters are advanced on the positive edge of the clock signal when the clock enable signal is in the logical “0” state. The configuration of the CD4017BC and CD4022BC permits medium speed operation and assure ...
MAX6800/MAX6801/MAX6802 3-Pin, Low-Power µP Reset Circuits General Description
... to 5.0V µP and digital systems. They increase circuit reliability and reduce cost by eliminating external components and adjustments. These devices perform a single function—they assert a reset signal whenever the VCC supply voltage declines below a preset threshold, keeping it asserted for a preset ...
... to 5.0V µP and digital systems. They increase circuit reliability and reduce cost by eliminating external components and adjustments. These devices perform a single function—they assert a reset signal whenever the VCC supply voltage declines below a preset threshold, keeping it asserted for a preset ...
PROsine 2.5 and 3.0
... a) Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. b) Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. c) Wear complete eye protection and clothing protection. Avoid touching eye ...
... a) Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. b) Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. c) Wear complete eye protection and clothing protection. Avoid touching eye ...
PSPICE Lecture #1 - Faculty Websites
... D. Click where you would like to place the part on the schematic. E. Use R to rotate the part as you place it on the schematic. Once it has been placed, it can be rotated, flipped, or mirrored by right-clicking on the part. F. Continue clicking on the schematic to place multiple parts (such as sever ...
... D. Click where you would like to place the part on the schematic. E. Use R to rotate the part as you place it on the schematic. Once it has been placed, it can be rotated, flipped, or mirrored by right-clicking on the part. F. Continue clicking on the schematic to place multiple parts (such as sever ...
PSPICE
... D. Click where you would like to place the part on the schematic. E. Use R to rotate the part as you place it on the schematic. Once it has been placed, it can be rotated, flipped, or mirrored by right-clicking on the part. F. Continue clicking on the schematic to place multiple parts (such as sever ...
... D. Click where you would like to place the part on the schematic. E. Use R to rotate the part as you place it on the schematic. Once it has been placed, it can be rotated, flipped, or mirrored by right-clicking on the part. F. Continue clicking on the schematic to place multiple parts (such as sever ...
ELECTRICAL MACHINES LABORATORY "................................................................"
... applications. In EME, you have all the main panels you need for analyzing an electrical machine, as measuring devices, supply systems, management systems, protection systems, synchronism and rectification systems, etc. This unit is prepared for working to a maximum power of 1 KW and all the componen ...
... applications. In EME, you have all the main panels you need for analyzing an electrical machine, as measuring devices, supply systems, management systems, protection systems, synchronism and rectification systems, etc. This unit is prepared for working to a maximum power of 1 KW and all the componen ...
NE02 Brochure
... Molded case circuit breakers typically have lower single-pole interrupting capabilities than their multi-pole interrupting rating. See discussion for section 240.85 on slash ratings and single pole interrupting capabilities. How does one know in practical applications if an overcurrent protective de ...
... Molded case circuit breakers typically have lower single-pole interrupting capabilities than their multi-pole interrupting rating. See discussion for section 240.85 on slash ratings and single pole interrupting capabilities. How does one know in practical applications if an overcurrent protective de ...
High Power Resistor Series
... Adjustable Resistor Application Notes Determination of End Resistance Value of FVR, DQS, DSRA, DSRB, BSR, BSQ: 1. Resistance Range means you can choose one maximum resistance value (End resistance value) at one of FVR, DQS, DSRA, DSRB, BSR, BSQ VR (Adjustable Resistor) type. 2. After End Resistance ...
... Adjustable Resistor Application Notes Determination of End Resistance Value of FVR, DQS, DSRA, DSRB, BSR, BSQ: 1. Resistance Range means you can choose one maximum resistance value (End resistance value) at one of FVR, DQS, DSRA, DSRB, BSR, BSQ VR (Adjustable Resistor) type. 2. After End Resistance ...
Breakers, Relays, and Disconnects
... Interrupt the current flow quickly enough to prevent or minimize damage to the component. Interrupt current flow quickly enough to contain any damage to that component alone, as well as protect the rest of the electrical system. Choices include fuses, overloads, or a protective relay to trip the m ...
... Interrupt the current flow quickly enough to prevent or minimize damage to the component. Interrupt current flow quickly enough to contain any damage to that component alone, as well as protect the rest of the electrical system. Choices include fuses, overloads, or a protective relay to trip the m ...
Notes on Maintaining Sub-1V Balance of an Ionizer
... to describe it is via a step function test where a sudden voltage change is applied to a control input of an ionizer and the resulting new balance of the ionizer is monitored. Figure 3 shows results of such a test. As shown, it takes 10..12 seconds for this particular ionizer to be within 80% of the ...
... to describe it is via a step function test where a sudden voltage change is applied to a control input of an ionizer and the resulting new balance of the ionizer is monitored. Figure 3 shows results of such a test. As shown, it takes 10..12 seconds for this particular ionizer to be within 80% of the ...
Buck converter
A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.