• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MODEL SR850 DSP Lock-In Amplifier
MODEL SR850 DSP Lock-In Amplifier

... amplitude (linear or log). 10 mA max output current. 4 BNC Analog to Digital inputs. Differential inputs with1 MΩ input impedance on both shield and center conductor. ±10 V full scale, 1 mV resolution. TTL trigger input triggers each data sample and/or start of scan. Analog output of signal amplifie ...
MAX793/MAX794/MAX795 3.0V/3.3V Adjustable Microprocessor Supervisory Circuits General Description
MAX793/MAX794/MAX795 3.0V/3.3V Adjustable Microprocessor Supervisory Circuits General Description

... Note 7: OUT switches from BATT to VCC when VCC rises above the reset threshold, if VBATT > VRST. In this case, switchover back to VCC occurs at the exact voltage that causes reset to be asserted, however, switchover occurs 200ms prior to reset. If VBATT < VRST, OUT switches from BATT to VCC when VCC ...
Power Around The World
Power Around The World

... phases, frequency and voltage – found in major foreign countries are listed in this report. In addition, the stability of the frequency and the number of wires to a commercial or residential installation are given where available. The current characteristics and other data furnished relate to domest ...
Power Around The World
Power Around The World

... phases, frequency and voltage – found in major foreign countries are listed in this report. In addition, the stability of the frequency and the number of wires toa commercial or residential installation are given where available. The current characteristics and other data furnished relate to domesti ...
Service Guide Specification
Service Guide Specification

... a. Removing or reinstalling any component, circuit board module or any other receiver assembly. b. Disconnecting or reconnecting any receiver electrical plug or other electrical connection. c. Connecting a test substitute in parallel with an electrolytic capacitor in the receiver. CAUTION: A wrong p ...
QO and QOB Miniature Circuit Breakers
QO and QOB Miniature Circuit Breakers

Relays and Meters - GE Industrial Solutions
Relays and Meters - GE Industrial Solutions

... Single Function Protection Relays.......................................22-128 Single Function Auxiliary Relays..........................................22-138 Substation Gateways and RTU.............................................22-140 ...
Ultra3000 Digital Servo Drives Installation Manual
Ultra3000 Digital Servo Drives Installation Manual

... publication 2098-DU003B-EN-P, includes important information about changes and updates to this Ultra3000 Digital Servo Drive Installation Manual. The document update used to be provided as a separate document, but is now incorporated into this installation manual, in the section immediately followin ...
GENERATOR PROTECTION
GENERATOR PROTECTION

... Interval and Delay Timers used together to detect intermittent pickups of arcing ground fault ...
DNV-RP-D102: Failure Mode and Effect Analysis (FMEA) of
DNV-RP-D102: Failure Mode and Effect Analysis (FMEA) of

ProNet Series AC Servo User`s Manual
ProNet Series AC Servo User`s Manual

... ■ Note that residual voltage still remains in the servodrive even after the power is turned off. Please be noted that even after the power is turned off, residual voltage still remains in the capacitor inside the servodrive. If inspection is to be performed after the power is turned off, always wait ...
INSTRUCTION MANUAL DISTANCE RELAY GRZ100
INSTRUCTION MANUAL DISTANCE RELAY GRZ100

INSTRUCTION MANUAL DISTANCE RELAY GRZ100
INSTRUCTION MANUAL DISTANCE RELAY GRZ100

... the length of the transmission line. This is to ensure that overreach tripping does not occur for external faults that occur beyond the busbar at the remote end. For internal faults that occur beyond the reach of zone 1, time delayed tripping by the zone 2 element is applied. High-speed tripping can ...
BDTIC www.BDTIC.com/infineon
BDTIC www.BDTIC.com/infineon

... The SmartLEWIS™ transceiver TDA5340 and the transmitter TDA5150 are low power devices based on RFCMOS technology. These combine outstanding RF performance with the flexibility of a digital approach. All the Infineon SmartLEWIS™ devices can be easily interfaced to any standard microprocessor through ...
Molded Case Circuit Breakers
Molded Case Circuit Breakers

MASTER SPECIFICATIONS Division 26
MASTER SPECIFICATIONS Division 26

Power Requirements for Cybex Products
Power Requirements for Cybex Products

Lecture 18: Input and Output
Lecture 18: Input and Output

Non-iterative algorithm of analytical synchronization of two
Non-iterative algorithm of analytical synchronization of two

mn-lcs4 r1
mn-lcs4 r1

... terminal), which transmits data, in a broadcast mode, via one of the pairs. Many ‘target’ devices are connected to this pair, which all simultaneously receive data from the controller. The controller is the only device with a line-driver connected to this pair - the target devices only have line-rec ...
PowerFlex 700H and 700S AC Drives, Frames 9...14 Installation
PowerFlex 700H and 700S AC Drives, Frames 9...14 Installation

... Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions ...
Dual-Core Intel® Xeon® Processor 7100 Series
Dual-Core Intel® Xeon® Processor 7100 Series

... Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whats ...
MAX6841–MAX6845 Ultra-Low-Voltage µP Reset Circuits and
MAX6841–MAX6845 Ultra-Low-Voltage µP Reset Circuits and

... When the VCC supply voltage falls below a preset threshold (MAX6841/MAX6842) or RESET IN falls below the adjustable threshold (MAX6843/MAX6844/MAX6845), reset asserts and stays asserted for a fixed timeout delay (Table 2) after VCC or RESET IN has risen above the reset threshold. The MAX6841–MAX6845 ...
SIMODRIVE 611 Drive Converter
SIMODRIVE 611 Drive Converter

... to provide for every possible contingency to be met in connection with installation, operation or maintenance. The contents of this document are neither part of an earlier or existing contract, agreement or a contract nor do they change this. The sales contract contains the entire obligation of Siem ...
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-

... a) following a voltage or reactive power instruction or directive; b) having its automatic voltage regulator or voltage regulating system in requirements R5 and R8 which such exceptions are containedservice or being in Appendix 1 of this reliability standard.voltage control mode; or c) making any as ...
< 1 ... 8 9 10 11 12 13 14 15 16 ... 1789 >

Buck converter



A buck converter is a voltage step down and current step up converter.The simplest way to reduce the voltage of a DC supply is to use a linear regulator (such as a 7805), but linear regulators waste energy as they operate by dissipating excess power as heat. Buck converters, on the other hand, can be remarkably efficient (95% or higher for integrated circuits), making them useful for tasks such as converting the main voltage in a computer (12V in a desktop, 12-24V in a laptop) down to the 0.8-1.8V needed by the processor.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report