• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
\ RAY ANGLE i
\ RAY ANGLE i

... across the sky. Thus, if direct sunlight is present, at least 60 Yet a further speci?c object of the present invention one photo detector will produce a corresponding, rela is to provide an input signal priority scheme which will tively high electrical signal indicative of its presence. If always ma ...
Enerlin`x - Schneider Electric
Enerlin`x - Schneider Electric

... This touch screen is well appreciated for real time value checking and control, directly on the front panel of the main switchboard On a PC display with common browser • Shows monitoring web pages hosted into the local Ethernet interfaces • Alarm events generate automatic email notifications • Al ...
Liebert Series 610 UPS Installation Manual - 100-225kVA, 60Hz, Three Phase Single-Module
Liebert Series 610 UPS Installation Manual - 100-225kVA, 60Hz, Three Phase Single-Module

EGN-1002-Microcontro..
EGN-1002-Microcontro..

... A) 5.5-15VDC on Vin. This will also provide 5 VDC regulated output on Vdd. B) Regulated 5V Input on Vdd. ...
ballast - Arlight
ballast - Arlight

... •Building Automation Systems ...
General Description Benefits and Features
General Description Benefits and Features

... The MAX14784E/MAX14786E/MAX14787E/MAX14789E full-duplex RS-485 transceivers are designed for robust communication in harsh industrial environments. All devices feature ±35kV ESD protection on the RS-485 pins and operate from a 3V to 5.5V supply with a 4mA no-load supply current (max). The MAX14784E/ ...
by Submitted in partial fulfilment of the requirements for the degree
by Submitted in partial fulfilment of the requirements for the degree

... frequency drift in oscillators. Thermal instability of a voltage-controlled oscillator (VCO) is a critical design factor for radio frequency ICs, such as transceiver circuits in communication networks, data link protocols, medical wireless sensor networks and microelectromechanical resonators. For e ...
GENERAL-PURPOSE INVERTER WITH ADVANCED VECTOR
GENERAL-PURPOSE INVERTER WITH ADVANCED VECTOR

... *3 The setting range for open-loop vector control 2 is 0 to 66Hz (for PROG: 103 , 0 to 132Hz). *4 When using the inverter of 200 V 30 kW or more with a cooling fan of 3-phase 230 V 50 Hz or 240 V 50/60 Hz power supply, a transformer for the cooling fan is required. *5 Use of a DC power supply is not ...
M-Flex™ Adjustable Speed Drive Controllers
M-Flex™ Adjustable Speed Drive Controllers

... operating M-Flex™ drive controllers. Installation, adjustment, repair, and maintenance of the drive controllers must be performed by qualified ...
LTM4619 - Dual, 26VIN, 4A DC/DC uModule Regulator
LTM4619 - Dual, 26VIN, 4A DC/DC uModule Regulator

... changes without sacrificing stability. The two outputs are interleaved with 180° phase to minimize the ripple noise and reduce the I/O capacitors. The device supports frequency synchronization and output voltage tracking for supply rail sequencing. Burst Mode operation or pulseskipping mode can be s ...
MAX4810/MAX4811/MAX4812 Dual, Unipolar/Bipolar, High-Voltage Digital Pulsers General Description
MAX4810/MAX4811/MAX4812 Dual, Unipolar/Bipolar, High-Voltage Digital Pulsers General Description

... described by JEDEC 51. The maximum power dissipation for the MAX4810/MAX4811/MAX4812 might be limited by the thermal protection included in the device. Note 2: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a fourlayer board. For detailed ...
Faraday Cup Award: High Sensitivity Tune - Indico
Faraday Cup Award: High Sensitivity Tune - Indico

... - Kick excitation used for operation. - Chirp and AC-dipole excitation with the transverse damper used for beam studies only. - The kicker is a huge 25 ohm magnetic structure excited with one turn pulse. - Typically the kick voltage is 500 V, giving very nice measurements. The voltage can go up to 5 ...
Fluke Template - Color
Fluke Template - Color

10-Port Constant-Current LED Drivers and I/O Expanders with PWM Intensity Control Features
10-Port Constant-Current LED Drivers and I/O Expanders with PWM Intensity Control Features

... The tradeoff for LED intensity control is between depth of current-control resolution, noise constraints, and software complexity: • For high LED resolution where each LED needs individual intensity settings, use the 8-bit PWM control plus the 1-bit analog control to get 9 bits of individual LED int ...
LonMark Americas Open Systems Specification
LonMark Americas Open Systems Specification

... LONMARK Americas is working hard to provide the resources necessary to successfully implement LONW ORKS® Open Systems. Over the past year a team of committed volunteers has spent countless hours working to evaluate and create the tools needed to make the process of specifying, enforcing, and impleme ...
BusWorks XT Series Ethernet I/O Modules
BusWorks XT Series Ethernet I/O Modules

... Screen shots of Windows-based configuration software. Using simple pull-down menus and userinput, your module is ready for use in a snap. ...
35% Wiring
35% Wiring

TOP242-250 - Power Integrations
TOP242-250 - Power Integrations

... 2. DCMAX of 78% allows smaller input storage capacitor, lower input voltage requirement and/or higher power capability. 3. Frequency reduction at light loads lowers the switching losses and maintains good cross regulation in multiple output supplies. 4. Higher switching frequency of 132 kHz reduces ...
www.geca.ac.in
www.geca.ac.in

Automotive Compilation
Automotive Compilation

... “Downlink” field detection and “uplink” field modulation can both be achieved using circuitry that consumes very little current. Furthermore, harnessing sufficient field energy to power these circuits in the key fob electronics can be achieved with relative ease. During the system design phase, care ...
User’s Manual Model PR300 Power and Energy Meter
User’s Manual Model PR300 Power and Energy Meter

... Displaying Measured, Instantaneous, and Maximum/Minimum Values ...................... 4-3 Example Display and Measuring Ranges of Active Power (Regenerative Power) .................... 4-3 Example Display and Measuring Ranges of Reactive Power .................................................... 4-3 ...
Rfid based security access control system Introduction In this
Rfid based security access control system Introduction In this

Axis controller CPX-CMAX-C1-1 Terminal CPX
Axis controller CPX-CMAX-C1-1 Terminal CPX

... Damage to the product from incorrect handling.  Switch off the supply voltage before mounting and installation work. Switch on sup­ ply voltage only when mounting and installation work are completely finished.  Never unplug or plug in the product and components attached to the axis connec­ ...
HW manual - TG Drives
HW manual - TG Drives

... All rights reserved. No part of this work may be reproduced in any form (by printing, photocopying, microfilm or any other method) or stored, processed, copied or distributed by electronic means without the written permission of Danaher Motion. ...
3 V to 5 V Single Supply, 200 kSPS 12
3 V to 5 V Single Supply, 200 kSPS 12

< 1 ... 27 28 29 30 31 32 33 34 35 ... 528 >

Control system



A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report