
a 14-Bit 333 kSPS Serial A/D Converter AD7851
... The offset and gain calibration spans are defined as the range of offset and gain errors that the AD7851 can calibrate. Note also that these are voltage spans and are not absolute voltages (i.e., the allowable system offset voltage presented at AIN(+) for the system offset error to be adjusted out w ...
... The offset and gain calibration spans are defined as the range of offset and gain errors that the AD7851 can calibrate. Note also that these are voltage spans and are not absolute voltages (i.e., the allowable system offset voltage presented at AIN(+) for the system offset error to be adjusted out w ...
SN74LV374AT 数据资料 dataSheet 下载
... and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s te ...
... and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s te ...
VACON NXS NXP User Manual
... cover of the drive are closed. The connections of the AC drive are live when the drive is connected to mains. WARNING! Disconnect the motor from the drive if an accidental start can be dangerous. When there is a power-up, a power break or a fault reset, the motor starts immediately if the start sign ...
... cover of the drive are closed. The connections of the AC drive are live when the drive is connected to mains. WARNING! Disconnect the motor from the drive if an accidental start can be dangerous. When there is a power-up, a power break or a fault reset, the motor starts immediately if the start sign ...
Analog Input, Output, and Relay Drive Output
... related to the health of equipment like generators, motors, or transformers. The accurate measurement of the voltage, current, or other parameters like temperature pressure or the vibration of power system equipment are prerequisites to any form of control, ranging from automatic closed-loop control ...
... related to the health of equipment like generators, motors, or transformers. The accurate measurement of the voltage, current, or other parameters like temperature pressure or the vibration of power system equipment are prerequisites to any form of control, ranging from automatic closed-loop control ...
AD9523-1 英文数据手册DataSheet 下载
... designs. It relies on an external VCXO to provide the reference jitter cleanup to achieve the restrictive low phase noise requirements necessary for acceptable data converter SNR performance. The input receivers, oscillator, and zero delay receiver provide both single-ended and differential operatio ...
... designs. It relies on an external VCXO to provide the reference jitter cleanup to achieve the restrictive low phase noise requirements necessary for acceptable data converter SNR performance. The input receivers, oscillator, and zero delay receiver provide both single-ended and differential operatio ...
MAX5380/MAX5381/MAX5382 Low-Cost, Low-Power, 8-Bit DACs with 2-Wire Serial Interface in SOT23 General Description
... be controlled by a bus master device. Figure 4 shows a typical application where up to four devices can be connected to the bus, provided they have different address settings. External pull-up resistors are not necessary on these lines (when driven by push-pull drivers), though these DACs can be use ...
... be controlled by a bus master device. Figure 4 shows a typical application where up to four devices can be connected to the bus, provided they have different address settings. External pull-up resistors are not necessary on these lines (when driven by push-pull drivers), though these DACs can be use ...
Very Low Power, Negative Rail Input, Rail-to
... This fully differential op amp features accurate output common-mode control that allows for dc-coupling when driving analog-to-digital converters (ADCs). This control, coupled with an input common-mode range below the negative rail as well as rail-to-rail output, allows for easy interfacing between ...
... This fully differential op amp features accurate output common-mode control that allows for dc-coupling when driving analog-to-digital converters (ADCs). This control, coupled with an input common-mode range below the negative rail as well as rail-to-rail output, allows for easy interfacing between ...
Share your feedback/comments at pak
... Input A is the addressing input, which controls which of the two data inputs, X0 or X1, will be transmitted to the output. If the A input switches back and forth at a frequency more than double the frequency of either digital signal, both signals will be accurately reproduced, and can be separated a ...
... Input A is the addressing input, which controls which of the two data inputs, X0 or X1, will be transmitted to the output. If the A input switches back and forth at a frequency more than double the frequency of either digital signal, both signals will be accurately reproduced, and can be separated a ...
Novel Advancements in Solid-State Magnet Control
... magnet is shown in green. As can be seen, using the solid-state control, the holding current is automatically reduced after 11 seconds and the load is maintained using approximately 24amps less than with the contactor control. The 24 amp reduction in magnet current equates to a reduction in the heat ...
... magnet is shown in green. As can be seen, using the solid-state control, the holding current is automatically reduced after 11 seconds and the load is maintained using approximately 24amps less than with the contactor control. The 24 amp reduction in magnet current equates to a reduction in the heat ...
Programmable Controller CQM1H - 5110
... An interrupt is executed after a set time, measured by one of the CPU Unit’s internal timers. ...
... An interrupt is executed after a set time, measured by one of the CPU Unit’s internal timers. ...
LT6100/LT6017 - Dual/Quad 3.2MHz, 0.8V/μs Low Power, Over-The-Top Precision Op Amp
... obtained by simply strapping or floating two gain select pins. Gain accuracy is better than 0.5% for all gains. The LT6100 sense inputs have a voltage range that extends from 4.1V to 48V, and can withstand a differential voltage of the full supply. This makes it possible to monitor the voltage acros ...
... obtained by simply strapping or floating two gain select pins. Gain accuracy is better than 0.5% for all gains. The LT6100 sense inputs have a voltage range that extends from 4.1V to 48V, and can withstand a differential voltage of the full supply. This makes it possible to monitor the voltage acros ...
G4 Wiring and Installation Manual
... Thank you for purchasing your Link Wire-In Engine Control Unit (ECU). Link G4 ECU's are an advanced, fully programmable microprocessor controlled Engine Management System. The G4 software platform boasts an impressive list of features giving a new level of user adjustment. This flexibility allows th ...
... Thank you for purchasing your Link Wire-In Engine Control Unit (ECU). Link G4 ECU's are an advanced, fully programmable microprocessor controlled Engine Management System. The G4 software platform boasts an impressive list of features giving a new level of user adjustment. This flexibility allows th ...
1
... The design considerations for high-speed data conversion 一般数据转化十分相似 ,但由于芯片型号的限制 ,加上 are, in many ways, similar to those for data conversion in 只有可靠的设计技术和结构才能使用 ,高速电路就显得 general. High speed circuits may sometimes seem different because device types can be limited and。 only certain design 有些不同 高速电路或系统 ...
... The design considerations for high-speed data conversion 一般数据转化十分相似 ,但由于芯片型号的限制 ,加上 are, in many ways, similar to those for data conversion in 只有可靠的设计技术和结构才能使用 ,高速电路就显得 general. High speed circuits may sometimes seem different because device types can be limited and。 only certain design 有些不同 高速电路或系统 ...
GE 80A GigaDLynx : Non-Isolated DC-DC Power Modules Preliminary Data Sheet
... The 80A Digital GigaDLynxTM power modules are non-isolated dc-dc converters that deliver up to 80A of output current. These modules operate over a wide range of input voltage (VIN =4.5Vdc - 14Vdc) and provide a precisely regulated output voltage from 0.6Vdc to 2Vdc, programmable via an external resi ...
... The 80A Digital GigaDLynxTM power modules are non-isolated dc-dc converters that deliver up to 80A of output current. These modules operate over a wide range of input voltage (VIN =4.5Vdc - 14Vdc) and provide a precisely regulated output voltage from 0.6Vdc to 2Vdc, programmable via an external resi ...
MAX1391/MAX1394 1.5V to 3.6V, 416ksps, 1-Channel True-Differential/ 2-Channel Single-Ended, 8-Bit, SAR ADCs
... The MAX1391/MAX1394 require an external reference V REF that has a wide range from 0.6V to V DD . The MAX1391 provides one true-differential analog input that accepts signals ranging from 0 to VREF (unipolar mode) or ±VREF/2 (bipolar mode). The MAX1394 provides two single-ended inputs that accept si ...
... The MAX1391/MAX1394 require an external reference V REF that has a wide range from 0.6V to V DD . The MAX1391 provides one true-differential analog input that accepts signals ranging from 0 to VREF (unipolar mode) or ±VREF/2 (bipolar mode). The MAX1394 provides two single-ended inputs that accept si ...
Technical Description PCM Modules ZM modular
... It gives important information about the system and the devices. Please read this technical description carefully before using the device! It will ensure smooth operation and prevention of errors, defects and damage to the system. Moreover, universal safety and accident prevention specifications mus ...
... It gives important information about the system and the devices. Please read this technical description carefully before using the device! It will ensure smooth operation and prevention of errors, defects and damage to the system. Moreover, universal safety and accident prevention specifications mus ...
a Complete 14-Bit, 3.0 MSPS Monolithic A/D Converter AD9243*
... the AD9243 performs well in communication systems employing Direct-IF Down Conversion since the SHA in the differential input mode can achieve excellent dynamic performance well beyond its specified Nyquist frequency of 1.5 MHz. A single clock input is used to control all internal conversion cycles. ...
... the AD9243 performs well in communication systems employing Direct-IF Down Conversion since the SHA in the differential input mode can achieve excellent dynamic performance well beyond its specified Nyquist frequency of 1.5 MHz. A single clock input is used to control all internal conversion cycles. ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.