• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Radiation Safety for the Cardiac Sonographer
Radiation Safety for the Cardiac Sonographer

... the source (increasing distance exponentially reduces exposure) and using shielding. From the Nuclear Regulatory Commission.12 for prolonged periods of time. Because the volume of patients receiving radioisotopes for nuclear scans shortly preceding the performance of TTE has increased, this exposure ...
Generation of Hard Quasimonochromatic Radiation Using a Table
Generation of Hard Quasimonochromatic Radiation Using a Table

... organic materials Concern Radiation-induced damage: photon energy deposited per unit mass (dose) can cause observable changes in structure ...
File
File

... 2. What are the names of the particles in the nucleus of an atom? a. Protons and neutrons b. Neutrons and electrons c. Protons and electrons 3. What type of nuclear radiation cannot penetrate skin? a. Alpha b. Beta c. Gamma 4. What type of nuclear radiation is an electromagnetic wave? a. Alpha b. Be ...
Each of the six sections of the written examination objectives is
Each of the six sections of the written examination objectives is

... Each of the six sections of the written examination objectives is designed to provide an ACVR eligible resident with a framework from which to study. The objectives are not all inclusive but should provide a minimum knowledge base needed to pass the written examination. A candidate must obtain a sco ...
dosgel_sur4 - University of Surrey
dosgel_sur4 - University of Surrey

... Figure 3(a) shows a selected 2-D slice from the 3-D image data-set obtained from an FXG gel phantom exposed to a cone-beam of X-rays. The silver X-ray tube target was operated at 50kVp, 0.6mA and the exposure time was about 30 minutes. 128 projections, each consisting of a plane of 128128 pixels, w ...
Ch 1 Basic Imaging Principles - Department of Engineering and
Ch 1 Basic Imaging Principles - Department of Engineering and

... To develop an imaging equation that incorporates the geometric effects, we utilize an idealized object tz(x,y) that is infinitesimally thin and located in a single plane given by the coordinate z and is capable of differently attenuating x-rays as a function of x and y. tz is transmittivity and repl ...
- Iranian Journal of Medical Physics
- Iranian Journal of Medical Physics

... abdomen X-rays were performed for all three age groups in all departments included in this study, except the maternity hospital (patients were only neonate), which is represented by No. 4 in figures. Figure 3. Mean ESD (µGy) for chest examination in group 5 ...
Final draft
Final draft

... computers. Inspectors may capture a digitized image, feed them into a computer and wait for a printout of the image with a accept or reject report. Systems will be able to scan a part and present a three-dimensional image to the radiographer, helping he or she locate the defect within that part. Ins ...
Diagnostic Imaging
Diagnostic Imaging

... a large tube that looks like a large doughnut standing on its side, and the person lies on the table in the center. – The X-ray tube rotates around the body. – The table slowly moves through the inside of the machine. – Each rotation yields several images of thin slices of the body. ...
Production of X-rays
Production of X-rays

... • The dose rate in a typical X-ray beam is estimated in Module ...
Optimal Tube Potential in Pediatric CT for Radiation
Optimal Tube Potential in Pediatric CT for Radiation

... data simulating 1/5 of the original dose, which is still acceptable to neuro radiologists for the purpose of assessing the size of the ventricle. ...
Computed Tomography Routine Examinations and the Related Risk
Computed Tomography Routine Examinations and the Related Risk

... tissues in a thin “slice” of the body. Computed tomography is used in cancer diagnosis in many different ways to detect abnormal growths, helps to diagnose the presence of a tumor, provides information about the stage of cancer, determines exactly where to perform a biopsy procedure. The x-rays, gan ...
Chapter 11
Chapter 11

...  Photons can be absorbed by the patient’s body part’s  Photons could pass right thru the patient’s body and enter the film, putting density on the film. These photons are called exit radiation or remnant radiation  Photons could hit something in the patient’s body, bounce off, and fly out in a ne ...
Beam abort in KEKB and Background measured by SVD
Beam abort in KEKB and Background measured by SVD

... Properties of the KEKB beam abort • Beam abort is done by kicker pulse magnets in KEKB. • The beam circulation period of KEKB is 10 msec. • About 100 msec delay in KEKB side to avoid beam aborts due to electric noise (can be shorter). • KEKB has its own strong beam abort detections to protect KEKB ...
Digital radiography detectors e A technical overview: Part 1
Digital radiography detectors e A technical overview: Part 1

... image, the SPS is scanned in a separate CR reader device. The readout is a process that follows exposure of the image plate and constitutes the second step of the CR imaging cycle. A red laser beam scans the photostimulable screen stimulating the emission of blue light photons under the excitation o ...
Low dose CT of the lumbar spine has better image quality than
Low dose CT of the lumbar spine has better image quality than

... of most anatomical structures. The strengths of the current study are that five reviewers took part in this study providing a wide range of experience in evaluating image quality, and that the study included tests of intra-individual and inter-individual agreement and an evaluation of whether BMI wa ...
Nuclear Medicine
Nuclear Medicine

... In nuclear medicine studies, the radiopharmaceutical given to the patient makes them, and the organ system or body part being studied, radioactive for a short time. This ionising radiation (usually a gamma ray) is emitted or released from the body, and can be detected and measured using a nuclear me ...
The Role of the Radiographer in Computed Tomography Imaging
The Role of the Radiographer in Computed Tomography Imaging

... Ireland) 20008 and subsequent amendments, 20069 and 201110, the Ionising Radiations Regulations 1999 (IRR’99)11 and Health and Safety at Work Act 197412 as well as local policies and procedures. 5.2 Training and continuing professional development (CPD) The National Occupational Standards for CT sca ...
Mar4
Mar4

... At each θ, the incident, unpolarized wave can be decomposed into 2 linearly polarized waves: one in the plane of the paper, one normal to the plane of the paper. These scatter into new waves in ratio cos2θ : 1 Thus, the component normal to the paper dominates the other ...
Lowering Radiation Dose in CT Imaging
Lowering Radiation Dose in CT Imaging

... There is a quadratic relationship between kVp and radiation dose. Therefore, by minimizing the kVp while maintaining the current (mAs) so that there are sufficient photons to maintain image quality, radiation dose can be substantially reduced (Figure 1). This is especially beneficial to pediatric pa ...
General Radiography - Santa Rosa Junior College
General Radiography - Santa Rosa Junior College

... Step 1: Explore and secure the approval from an SRJC affiliated Radiology Department prior to contacting the program. Step 2: Make an appointment with program officials to initiate and work out a plan of study and/or clinical experience. Step 3: Using the following paragraph as a sample to complete ...
Radiation Dose in Interventional Radiology PDF
Radiation Dose in Interventional Radiology PDF

... describes the total energy delivered by the x-ray tube. DAP is measured at a point close to the source of X-rays – often within the collimator housing. DAP is related to stochastic risk since it describes the total energy absorbed by all tissues in the patient. DAP is less useful for estimating dete ...
Media Talking Points What is Rad Tech Week? Rad Tech Week is
Media Talking Points What is Rad Tech Week? Rad Tech Week is

... X-ray Discovery Day marks the discovery of the X-ray on Nov. 8, 1895, by German physicist Wilhelm Conrad Roentgen. Nearly 120 years later, the X-ray remains the most frequently used form of medical imaging. The science behind the X-ray has provided the basis for much of the imaging equipment used in ...
3D Radiography Breakthrough: Applications for Dental Professionals
3D Radiography Breakthrough: Applications for Dental Professionals

... –Initially, view was only tomographic (slice views) and too large slice intervals (1cm) for dentistry. Dentistry’s Trend for ~100 years •Higher quality film images •Lower x-ray dose •More compact x-ray units •Faster exposures •Quicker film development •Smaller & more comfortable film packets ...
MASTER`S PROGRAMME IN MEDICAL PHYSICS
MASTER`S PROGRAMME IN MEDICAL PHYSICS

... Year 2 is devoted to a supervised full time clinical training to be performed in one accreditated hospitals. The student should \practices covering mainly a specific area of medical physics (medical physics for diagnostic imaging or medical physics for radiation therapy. Activities to perform, ...
< 1 ... 38 39 40 41 42 43 44 45 46 ... 56 >

Industrial radiography

Industrial radiography is the use of ionizing radiation to view objects in a way that cannot be seen otherwise. It is not to be confused with the use of ionizing radiation to change or modify objects; radiography's purpose is strictly viewing. Industrial radiography has grown out of engineering, and is a major element of nondestructive testing. It is a method of inspecting materials for hidden flaws by using the ability of short X-rays and gamma rays to penetrate various materials. Two ways to inspect materials for flaws is to utilize X-ray computed tomography or Industrial computed tomography scanning.
  • studyres.com © 2025