Philips receives FDA 510(k) clearance for IQon Spectral CT
... significantly add value to help improve patient care.” Philips IQon Spectral CT was developed in close collaboration with clinicians and is designed to overcome some of their most immediate challenges, including workflow and image management issues. The technology can discriminate between X-ray phot ...
... significantly add value to help improve patient care.” Philips IQon Spectral CT was developed in close collaboration with clinicians and is designed to overcome some of their most immediate challenges, including workflow and image management issues. The technology can discriminate between X-ray phot ...
Foetus-in-foetu: Imaging Diagnosis by the Presence of
... A wide range of age of presentation has been document, varying from newborn to 27 years.5 Approximately 90 cases have been documented in the literature to date.1,2,6,7 The preoperative diagnosis of foetus-in-foetu was made in only 16.7% of the cases reported before 1980, which may be explained by th ...
... A wide range of age of presentation has been document, varying from newborn to 27 years.5 Approximately 90 cases have been documented in the literature to date.1,2,6,7 The preoperative diagnosis of foetus-in-foetu was made in only 16.7% of the cases reported before 1980, which may be explained by th ...
CT Protocol Selection in PET-CT Imaging
... Computed tomography (CT) acquisition during positron emission tomography (PET)-CT imaging is often performed for a variety of purposes. In whole body PET-CT imaging, the CT portion can be used for: ...
... Computed tomography (CT) acquisition during positron emission tomography (PET)-CT imaging is often performed for a variety of purposes. In whole body PET-CT imaging, the CT portion can be used for: ...
American College of Radiology Clinical Statement on Noninvasive
... and scan pitch. Moreover, automated xray dose-shaping algorithms and x-ray tube pulsing, when available, should be applied to minimize radiation exposure while allowing diagnostic image quality. As with all examinations that use ionizing radiation, cardiac CT should be performed with a radiation dos ...
... and scan pitch. Moreover, automated xray dose-shaping algorithms and x-ray tube pulsing, when available, should be applied to minimize radiation exposure while allowing diagnostic image quality. As with all examinations that use ionizing radiation, cardiac CT should be performed with a radiation dos ...
Generation of Hard Quasimonochromatic Radiation Using a Table
... Applications to the life sciences • Potential to form high spatial resolution images in hydrated bio-material • Ability to identify atomic elements by the coincidence between photon energy and atomic resonances of the constituents of organic materials Concern Radiation-induced damage: photon energy ...
... Applications to the life sciences • Potential to form high spatial resolution images in hydrated bio-material • Ability to identify atomic elements by the coincidence between photon energy and atomic resonances of the constituents of organic materials Concern Radiation-induced damage: photon energy ...
Course Descriptions
... Exploration and analysis of topics within the discipline to meet individual student-defined course description, goals, objectives, topical outline and methods of evaluation in coordination with and approved by the instructor. This course may be taken four times for credit as long as different topics ...
... Exploration and analysis of topics within the discipline to meet individual student-defined course description, goals, objectives, topical outline and methods of evaluation in coordination with and approved by the instructor. This course may be taken four times for credit as long as different topics ...
contrast enhansed spectral mammography
... Mammography is a reliable tool, but has limitations Dense breast tissue can overlap with lesions Lesions are not always visible with x-ray Interpretation of images can vary among radiologists ...
... Mammography is a reliable tool, but has limitations Dense breast tissue can overlap with lesions Lesions are not always visible with x-ray Interpretation of images can vary among radiologists ...
Applications of Tomographic Imaging in Nuclear Medicine
... It can be seen that not all of the recorded events actually have energies of around 140 keV – the energy of 99mTc γ-rays. The discriminator, which is usually a single channel analyzer, sets an energy window centered on the photopeak, and rejects all the photons that are appear outside the window. Th ...
... It can be seen that not all of the recorded events actually have energies of around 140 keV – the energy of 99mTc γ-rays. The discriminator, which is usually a single channel analyzer, sets an energy window centered on the photopeak, and rejects all the photons that are appear outside the window. Th ...
pdf
... The mean CTDIvol and DLP values from RP-CT (38.1 mGy, 1472 mGy·cm) are approximately four times higher than for DG-CT (9.63 mGy, 376.5 mGy·cm). The CT scan length for both RP-CT (mean 37.8 cm) and DG-CT (mean 37.5cm) were similar (p=0.549). The CTDIvol in both RP-CT and DG#CT CTDIvol increase with h ...
... The mean CTDIvol and DLP values from RP-CT (38.1 mGy, 1472 mGy·cm) are approximately four times higher than for DG-CT (9.63 mGy, 376.5 mGy·cm). The CT scan length for both RP-CT (mean 37.8 cm) and DG-CT (mean 37.5cm) were similar (p=0.549). The CTDIvol in both RP-CT and DG#CT CTDIvol increase with h ...
I. Radiographic Terminology
... Viewing from the same perspective as the x-ray tube Marked R/L by the side of the patient closet to the IR Viewing from the same perspective as the x-ray tube Crosswise and p’t upside on view box upside ...
... Viewing from the same perspective as the x-ray tube Marked R/L by the side of the patient closet to the IR Viewing from the same perspective as the x-ray tube Crosswise and p’t upside on view box upside ...
Metastatic Prostate Cancer Presenting as Acute Appendicitis: A
... nearly eight thousand appendectomy specimens found an incidental tumor occurrence approaching 0.9%.5 The series revealed less than one third of tumors were secondary to metastatic spread, and none were from a prostatic source. This unusual case highlights the challenges of radiologically assessing p ...
... nearly eight thousand appendectomy specimens found an incidental tumor occurrence approaching 0.9%.5 The series revealed less than one third of tumors were secondary to metastatic spread, and none were from a prostatic source. This unusual case highlights the challenges of radiologically assessing p ...
A quality assurance phantom for electronic portal
... Changes in EPID technology are providing unsurpassed image quality for patient setup and verification. The reviews of EPID technology have been presented by several investigators for older and outdated systems.(4-7) Modern linear accelerators are equipped with advanced EPID designs which utilize amo ...
... Changes in EPID technology are providing unsurpassed image quality for patient setup and verification. The reviews of EPID technology have been presented by several investigators for older and outdated systems.(4-7) Modern linear accelerators are equipped with advanced EPID designs which utilize amo ...
Role of Multiplanar Reconstruction Imaging and Three
... of complex fractures. Small structures that are not well seen with conventional CT imaging can be clearly depicted using MPR and 3D overlapping reconstruction at small intervals. Reformatted images also provide complementary information about various conditions including congenital malformation, vas ...
... of complex fractures. Small structures that are not well seen with conventional CT imaging can be clearly depicted using MPR and 3D overlapping reconstruction at small intervals. Reformatted images also provide complementary information about various conditions including congenital malformation, vas ...
Assessment of a Ring-Enhancing Intracranial Mass
... a necrotic tumor and cerebral abscess is often difficult with CT or conventional MRI. • Diffusion Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping can help differentiate the two. • Proton MR Spectroscopy ‐ improving the accuracy of diagnosis with MR. ...
... a necrotic tumor and cerebral abscess is often difficult with CT or conventional MRI. • Diffusion Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping can help differentiate the two. • Proton MR Spectroscopy ‐ improving the accuracy of diagnosis with MR. ...
Ultrasound based Respiratory Motion Compensation - CAMP-TUM
... Abstract. For image-guided interventions, the patient respiratory motion has to be considered when integrating pre-operative plans and imaging into the interventional suite. Ultrasound is particularly attractive for obtaining live information about anatomical changes, without adding further radiatio ...
... Abstract. For image-guided interventions, the patient respiratory motion has to be considered when integrating pre-operative plans and imaging into the interventional suite. Ultrasound is particularly attractive for obtaining live information about anatomical changes, without adding further radiatio ...
GE CT Clarity - UW Radiology - University of Wisconsin–Madison
... for their needs. To date, over 10,000 unique image quality reviews have been received. "We are able to analyze the performance of our protocols across each of our scanners, for each of our patient sizes", says Dr. Szczykutowicz who is spearheading the compilation and analysis of the QA data. This QA ...
... for their needs. To date, over 10,000 unique image quality reviews have been received. "We are able to analyze the performance of our protocols across each of our scanners, for each of our patient sizes", says Dr. Szczykutowicz who is spearheading the compilation and analysis of the QA data. This QA ...
Winners and Losers
... •Patient underwent colectomy and 8 out of 9 nodes tested were positive for metastases ...
... •Patient underwent colectomy and 8 out of 9 nodes tested were positive for metastases ...
- Iranian Journal of Medical Physics
... all units had total filtration more than 2.5 mmAl; also, most of them were not newly built facilities (more than 10 years since construction). Figure 1 clearly demonstrates that infants received the highest dose in chest examinations at center No. 4 (before optimization). This is attributed to highe ...
... all units had total filtration more than 2.5 mmAl; also, most of them were not newly built facilities (more than 10 years since construction). Figure 1 clearly demonstrates that infants received the highest dose in chest examinations at center No. 4 (before optimization). This is attributed to highe ...
Society of Nuclear Medicine
... Myocardial perfusion imaging utilizes an intravenously administered radiopharmaceutical to depict the distribution of nutritional blood flow in the myocardium. Perfusion imaging identifies areas of reduced myocardial blood flow associated with ischemia or scar. The relative regional distribution of ...
... Myocardial perfusion imaging utilizes an intravenously administered radiopharmaceutical to depict the distribution of nutritional blood flow in the myocardium. Perfusion imaging identifies areas of reduced myocardial blood flow associated with ischemia or scar. The relative regional distribution of ...
Product Information
... The combination of Transflux™ & Transset™ allows the administration of contrast media via a power injector without changing the syringes on a “per-patient-basis”. When used in accordance with manufacturer’s instructions, this procedure eliminates the risk of cross contamination. (“Study on Microbial ...
... The combination of Transflux™ & Transset™ allows the administration of contrast media via a power injector without changing the syringes on a “per-patient-basis”. When used in accordance with manufacturer’s instructions, this procedure eliminates the risk of cross contamination. (“Study on Microbial ...
Virtual dental implant planning: the next step
... This ushered in the era of 3-D dental imaging, sparking a rapid development of dental CBCT scanners by a number of companies. To date, there are more than 30 such CBCT machines available on the market worldwide produced by a wide variety of companies.3 During the last decade, as recognition in the c ...
... This ushered in the era of 3-D dental imaging, sparking a rapid development of dental CBCT scanners by a number of companies. To date, there are more than 30 such CBCT machines available on the market worldwide produced by a wide variety of companies.3 During the last decade, as recognition in the c ...
Gas Phase UTE MRI of Propane and Propene
... pressures was shown about 15 years ago, with 2-dimensional (2D) images of flowing and static gas and flow velocity maps in pipes and multichannel monolith structures detected using a spin-echo pulse sequence (28, 29). In addition to the low spin density of gases, the rapid diffusion of gases in appl ...
... pressures was shown about 15 years ago, with 2-dimensional (2D) images of flowing and static gas and flow velocity maps in pipes and multichannel monolith structures detected using a spin-echo pulse sequence (28, 29). In addition to the low spin density of gases, the rapid diffusion of gases in appl ...
The Basic Modalities ~ Ultrasound Mammography
... waves very well. As a result, a simple cyst will appear completely black on ultrasound; this black appearance is called “anechoic,” meaning that the fluid produces no echoes, or does not make any of the sound waves bounce back, because the sound waves are transmitted through it so easily. ...
... waves very well. As a result, a simple cyst will appear completely black on ultrasound; this black appearance is called “anechoic,” meaning that the fluid produces no echoes, or does not make any of the sound waves bounce back, because the sound waves are transmitted through it so easily. ...
DIQUAD, LLC– Dental Image Quality and Dose
... lay press about high radiation doses from x-ray examinations. One must know what radiation doses are being used to know if you are doing a good job! • If the median Patient Radiation Dose is 185 mrad, why should some facilities be using three or more times that amount of radiation to produce a radio ...
... lay press about high radiation doses from x-ray examinations. One must know what radiation doses are being used to know if you are doing a good job! • If the median Patient Radiation Dose is 185 mrad, why should some facilities be using three or more times that amount of radiation to produce a radio ...
Medical imaging

Medical imaging is the technique and process of creating visual representations of the interior of a body for clinical analysis and medical intervention. Medical imaging seeks to reveal internal structures hidden by the skin and bones, as well as to diagnose and treat disease. Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities. Although imaging of removed organs and tissues can be performed for medical reasons, such procedures are usually considered part of pathology instead of medical imaging.As a discipline and in its widest sense, it is part of biological imaging and incorporates radiology which uses the imaging technologies of X-ray radiography, magnetic resonance imaging, medical ultrasonography or ultrasound, endoscopy, elastography, tactile imaging, thermography, medical photography and nuclear medicine functional imaging techniques as positron emission tomography.Measurement and recording techniques which are not primarily designed to produce images, such as electroencephalography (EEG), magnetoencephalography (MEG), electrocardiography (ECG), and others represent other technologies which produce data susceptible to representation as a parameter graph vs. time or maps which contain information about the measurement locations. In a limited comparison these technologies can be considered as forms of medical imaging in another discipline.Up until 2010, 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 made up about 50% of total ionizing radiation exposure in the United States.In the clinical context, ""invisible light"" medical imaging is generally equated to radiology or ""clinical imaging"" and the medical practitioner responsible for interpreting (and sometimes acquiring) the images is a radiologist. ""Visible light"" medical imaging involves digital video or still pictures that can be seen without special equipment. Dermatology and wound care are two modalities that use visible light imagery. Diagnostic radiography designates the technical aspects of medical imaging and in particular the acquisition of medical images. The radiographer or radiologic technologist is usually responsible for acquiring medical images of diagnostic quality, although some radiological interventions are performed by radiologists.As a field of scientific investigation, medical imaging constitutes a sub-discipline of biomedical engineering, medical physics or medicine depending on the context: Research and development in the area of instrumentation, image acquisition (e.g. radiography), modeling and quantification are usually the preserve of biomedical engineering, medical physics, and computer science; Research into the application and interpretation of medical images is usually the preserve of radiology and the medical sub-discipline relevant to medical condition or area of medical science (neuroscience, cardiology, psychiatry, psychology, etc.) under investigation. Many of the techniques developed for medical imaging also have scientific and industrial applications.Medical imaging is often perceived to designate the set of techniques that noninvasively produce images of the internal aspect of the body. In this restricted sense, medical imaging can be seen as the solution of mathematical inverse problems. This means that cause (the properties of living tissue) is inferred from effect (the observed signal). In the case of medical ultrasonography, the probe consists of ultrasonic pressure waves and echoes that go inside the tissue to show the internal structure. In the case of projectional radiography, the probe uses X-ray radiation, which is absorbed at different rates by different tissue types such as bone, muscle and fat.The term noninvasive is used to denote a procedure where no instrument is introduced into a patient's body which is the case for most imaging techniques used.