• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Modified Seried Inverter
Modified Seried Inverter

A Comparitive Study on Different Control Algorithms of
A Comparitive Study on Different Control Algorithms of

MAX9121/MAX9122 Quad LVDS Line Receivers with Integrated Termination and Flow-Through Pinout General Description
MAX9121/MAX9122 Quad LVDS Line Receivers with Integrated Termination and Flow-Through Pinout General Description

... inputs and translate them to LVCMOS outputs. The MAX9122 features integrated parallel termination resistors (nominally 107Ω), which eliminate the requirement for four discrete termination resistors and reduce stub lengths. The MAX9121 inputs are high impedance and require an external termination res ...
An Si–SiGe BiCMOS Direct-Conversion Mixer With Second-Order and Third-Order Nonlinearity
An Si–SiGe BiCMOS Direct-Conversion Mixer With Second-Order and Third-Order Nonlinearity

Electra 450KW-700KW Digital Load Bank Operator`s Manual
Electra 450KW-700KW Digital Load Bank Operator`s Manual

... 1. Start-up generator set or bring other test source on line. 2. Press the “Control Power”“On” button on the Main Screen. If multiple units are connected to form one system the Main Screen is only available via the Master Load Bank. 3. Visually observe correct fan operation, check air intake for obs ...
SIMULATION OF A SERIES RESONANT CIRCUIT  ECE562: Power Electronics I
SIMULATION OF A SERIES RESONANT CIRCUIT ECE562: Power Electronics I

... You need to re-solve the parallel resonant circuit with Capacitor ESR and see its effects on the magnitude and phase plots in some detail. For example choose the ratio of the C ESR to the load resistance to be in the ratio range from 0.01 to ...
dynaMITE 300KW-400KW Digital Load Bank
dynaMITE 300KW-400KW Digital Load Bank

... 1. Start-up generator set or bring other test source on line. 2. Press the “Control Power”“On” button on the Main Screen. If multiple units are connected to form one system the Main Screen is only available via the Master Load Bank. 3. Visually observe correct fan operation, check air intake for obs ...
Antenna Fundamentals
Antenna Fundamentals

Microcontroller Systems ELET 3232 Topic 22: Load Analysis 1
Microcontroller Systems ELET 3232 Topic 22: Load Analysis 1

... information regarding the components to be used A detailed analysis will provide documented proof that the design will work reliably It is much better to design using worst-case design rules rather than attempt to correct problems later Worst-case design efforts result in direct cost and time ...
W5A-580 Transmission Control Sys 1998
W5A-580 Transmission Control Sys 1998

... sense circuit: open circuit, high resistance, short circuit to high voltage or short circuit to ground Transmission to TCM speed / temperature sensors ground circuit: open circuit or short circuit to high voltage (DTC P0710 will also be flagged) Transmission internal n2 speed sensor sense circuit: o ...
dl 2616 two pulse control unit
dl 2616 two pulse control unit

IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

Part A –RC circuit, RL circuits, and AC Sweeps (22 points)
Part A –RC circuit, RL circuits, and AC Sweeps (22 points)

... The two basic types of filters we will consider in this part are low pass filters (LPF) and high pass filters (HPF). An idealized representation of these two types of filters is shown in Figure B-2. Low pass filters filter out high frequencies while allowing low frequencies to pass through unchanged ...
STLC3075
STLC3075

MAX1044/ICL7660 - Switched-Capacitor Voltage Converters
MAX1044/ICL7660 - Switched-Capacitor Voltage Converters

... Using the BOOST Pin For the MAX1044, connecting the BOOST pin to the V+ pin raises the oscillator frequency by a factor of about 6. Figure 6 shows this connection. Higher frequency operation lowers output impedance, reduces output ripple, allows the use of smaller capacitors, and shifts switching no ...
AN4007
AN4007

S-Parameters
S-Parameters

... The waves going towards the n-port are a = (a1, a2, ..., an), the waves travelling away from the n-port are b = (b1, b2, ..., bn). By definition currents going into the n-port are counted positively and currents flowing out of the n-port negatively. The wave a1 is going into the n-port at port 1 is ...
Aalborg Universitet Improved Droop Control Strategy for Grid-Connected Inverters
Aalborg Universitet Improved Droop Control Strategy for Grid-Connected Inverters

HIGH-VOLTAGE, LOW-DISTORTION, CURRENT-FEEDBACK OPERATIONAL AMPLIFIERS THS3092 THS3096
HIGH-VOLTAGE, LOW-DISTORTION, CURRENT-FEEDBACK OPERATIONAL AMPLIFIERS THS3092 THS3096

... This data was taken using the JEDEC standard High-K test PCB. Power rating is determined with a junction temperature of 125°C. This is the point where distortion starts to substantially increase. Thermal management of the final PCB should strive to keep the junction temperature at or below 125°C for ...
ADM3485E 数据手册DataSheet 下载
ADM3485E 数据手册DataSheet 下载

... ±15 kV ESD protection, suitable for half-duplex communication on multipoint bus transmission lines. The ADM3485E is designed for balanced data transmission and complies with TIA/EIA standards RS­485 and RS-422. The ADM3485E is a half-duplex transceiver that shares differential lines and has separate ...
Optimal adaptive estimation algorithm for harmonic
Optimal adaptive estimation algorithm for harmonic

Get cached
Get cached

... Since the signals vfH and v, are periodic, the error, e, is statistically stationary. Therefore, the expected value of the square of the error E results in a quadratic function which has a guaranteed minimum for real physical signals [Ref. 6]. Then by minimizing the mean square of the error (MSE), t ...
MAX1927/MAX1928 Low-Output-Voltage, 800mA, PWM Step-Down DC-DC Converters General Description
MAX1927/MAX1928 Low-Output-Voltage, 800mA, PWM Step-Down DC-DC Converters General Description

DRV600 数据资料 dataSheet 下载
DRV600 数据资料 dataSheet 下载

AN#49
AN#49

< 1 ... 17 18 19 20 21 22 23 24 25 ... 93 >

Standing wave ratio



In radio engineering and telecommunications, standing wave ratio (SWR) is a measure of impedance matching of loads to the characteristic impedance of a transmission line or waveguide. Impedance mismatches result in standing waves along the transmission line, and SWR is defined as the ratio of the partial standing wave's amplitude at an antinode (maximum) to the amplitude at a node (minimum) along the line.The SWR is usually thought of in terms of the maximum and minimum AC voltages along the transmission line, thus called the voltage standing wave ratio or VSWR (sometimes pronounced ""viswar""). For example, the VSWR value 1.2:1 denotes an AC voltage due to standing waves along the transmission line reaching a peak value 1.2 times that of the minimum AC voltage along that line. The SWR can as well be defined as the ratio of the maximum amplitude to minimum amplitude of the transmission line's currents, electric field strength, or the magnetic field strength. Neglecting transmission line loss, these ratios are identical.The power standing wave ratio (PSWR) is defined as the square of the VSWR, however this terminology has no physical relation to actual powers involved in transmission.The SWR can be measured with an instrument called an SWR meter. Since SWR is defined relative to the transmission line's characteristic impedance, the SWR meter must be constructed for that impedance; in practice most transmission lines used in these applications are coaxial cables with an impedance of either 50 or 75 ohms. Checking the SWR is a standard procedure in a radio station, for instance, to verify impedance matching of the antenna to the transmission line (and transmitter). Unlike connecting an impedance analyzer (or ""impedance bridge"") directly to the antenna (or other load), the SWR does not measure the actual impedance of the load, but quantifies the magnitude of the impedance mismatch just performing a measurement on the transmitter side of the transmission line.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report