An explanation of standard vs high performance ignition coils
... systems even though our cars have 12V systems (this is not a problem due to the ballast wire). One very important consideration is your ignition system, points or electronic. Points can tolerate more current than an electronic ignition module. The standard coil draws 6V/1.5 =4A while running. The ig ...
... systems even though our cars have 12V systems (this is not a problem due to the ballast wire). One very important consideration is your ignition system, points or electronic. Points can tolerate more current than an electronic ignition module. The standard coil draws 6V/1.5 =4A while running. The ig ...
Part B: Input and Output Impedance and Impedance Matching
... measured object has a high output impedance. In this case, the instrument draws too much current, which creates a significant voltage drop due to the high output impedance, altering the measurement. In measurement, one wants high input impedance for the instrument and low output impedance for the me ...
... measured object has a high output impedance. In this case, the instrument draws too much current, which creates a significant voltage drop due to the high output impedance, altering the measurement. In measurement, one wants high input impedance for the instrument and low output impedance for the me ...
Chapter 3 VOLTAGE CONTROL
... It is necessary to provide constancy of the alternator terminal voltage during normal small and slow changes in the load. For this purpose the alternators are provided with Automatic Voltage Regulator (AVR). The exciter is the main component in the AVR loop. It delivers DC power to the alternator fi ...
... It is necessary to provide constancy of the alternator terminal voltage during normal small and slow changes in the load. For this purpose the alternators are provided with Automatic Voltage Regulator (AVR). The exciter is the main component in the AVR loop. It delivers DC power to the alternator fi ...
HIGH POWER 3-PHASE AUXILIARY POWER SUPPLY DESIGN
... From Eq. 2, imposing Vin=Vinmin=220V, Np/Ns = 10, and considering the normal mode switching frequency, the maximum duty cycle and the maximum on time are: ...
... From Eq. 2, imposing Vin=Vinmin=220V, Np/Ns = 10, and considering the normal mode switching frequency, the maximum duty cycle and the maximum on time are: ...
`Onan` Gate Reactor 315-102
... NOT back and forth). (There are commercial toroid-winding machines made and available -- IF you have the $10,000 + to buy one!) The ‘shuttle’ used was about 3-feet long, about 1” wide, and about 1/8” thick, made of stiff cardboard, with a half-‘H’ at each end (about ½” deep) to hold the wire in-plac ...
... NOT back and forth). (There are commercial toroid-winding machines made and available -- IF you have the $10,000 + to buy one!) The ‘shuttle’ used was about 3-feet long, about 1” wide, and about 1/8” thick, made of stiff cardboard, with a half-‘H’ at each end (about ½” deep) to hold the wire in-plac ...
Household Magnets
... Hard magnetic materials have domains that don’t grow or shrink easily, so they are hard to magnetize or demagnetize. They can be magnetized permanently. ...
... Hard magnetic materials have domains that don’t grow or shrink easily, so they are hard to magnetize or demagnetize. They can be magnetized permanently. ...
Using Thyristors in Heating Applications
... In burst fire mode the thyristors are used in the form of a 'solid state contactor'. The thyristors are cycled on for a period, and then off. By varying the length of the on period relative to the off period the power to the load may be controlled. Thyristors have two advantages over contactors; the ...
... In burst fire mode the thyristors are used in the form of a 'solid state contactor'. The thyristors are cycled on for a period, and then off. By varying the length of the on period relative to the off period the power to the load may be controlled. Thyristors have two advantages over contactors; the ...
INSTRUCTION MANUAL CURRENT TRANSFORMER EXCITATION
... Multi-Amp Corporation warrants to the original purchaser that the product is free from defects in material and workmanship for a period of one (1) year from date of shipment. This warranty is limited and shall not apply to equipment which has damage, or cause of defect, due to accident, negligence, ...
... Multi-Amp Corporation warrants to the original purchaser that the product is free from defects in material and workmanship for a period of one (1) year from date of shipment. This warranty is limited and shall not apply to equipment which has damage, or cause of defect, due to accident, negligence, ...
Generator Downsizing Request Form
... R. For combined cycle plants, specify the plant net output capacity (MW) for an outage of the steam turbine or an outage of a single combustion turbine: 3. Synchronous Generator – General Information: (Please repeat the following for each generator model) A. Rated Generator Speed (rpm): B. Rated MVA ...
... R. For combined cycle plants, specify the plant net output capacity (MW) for an outage of the steam turbine or an outage of a single combustion turbine: 3. Synchronous Generator – General Information: (Please repeat the following for each generator model) A. Rated Generator Speed (rpm): B. Rated MVA ...
PS201002EN
... secondary connectors. Longer stud lengths may be required for user-supplied secondary connectors. Larger thread size or length, or both, may be required if materials other than copper are used. Stud thread sizes are in inches only 6 of 10 • April 2016 • Supersedes August 2012 (G201-20-1) ©2016 Eaton ...
... secondary connectors. Longer stud lengths may be required for user-supplied secondary connectors. Larger thread size or length, or both, may be required if materials other than copper are used. Stud thread sizes are in inches only 6 of 10 • April 2016 • Supersedes August 2012 (G201-20-1) ©2016 Eaton ...
G49045358
... proposed for power-quality improvement in the three-phase four-wire distribution system. The source voltages in the distribution systems are also experiencing power quality problems, such as harmonics, unbalance, flicker, sag, swell, etc. The distribution static compensator (DSTATCOM) is proposed fo ...
... proposed for power-quality improvement in the three-phase four-wire distribution system. The source voltages in the distribution systems are also experiencing power quality problems, such as harmonics, unbalance, flicker, sag, swell, etc. The distribution static compensator (DSTATCOM) is proposed fo ...
Transformer types
A variety of types of electrical transformer are made for different purposes. Despite their design differences, the various types employ the same basic principle as discovered in 1831 by Michael Faraday, and share several key functional parts.