
Keysight Technologies Techniques for Advanced Cable Testing
... power handling and voltage breakdown on a coaxial cable as a function of ratio D/d. The values shown in the figure have all been normalized to their respective minimum or maximum values for comparison purposes. These curves are based on the equations [4] listed in Table 2. From Figure 3, coaxial cab ...
... power handling and voltage breakdown on a coaxial cable as a function of ratio D/d. The values shown in the figure have all been normalized to their respective minimum or maximum values for comparison purposes. These curves are based on the equations [4] listed in Table 2. From Figure 3, coaxial cab ...
Chaper 5 - cs.csubak.edu
... Another parameter of the amplifier is the current gain, which is defined as the ratio of current delivered to the load to the current flowing into the input. For a CE stage, it is equal to . CH5 Bipolar Amplifiers ...
... Another parameter of the amplifier is the current gain, which is defined as the ratio of current delivered to the load to the current flowing into the input. For a CE stage, it is equal to . CH5 Bipolar Amplifiers ...
Double-Circuit Transmission Lines Fault location Algorithm
... in the case of fault resistance with 10 [ohm]. In case 1, the error is very large. This demonstrates that the algorithm applicable for single lines cannot be efficient to apply to double-circuit lines since the mutual impedance is not considered. The error in case 2 is still greater than the propose ...
... in the case of fault resistance with 10 [ohm]. In case 1, the error is very large. This demonstrates that the algorithm applicable for single lines cannot be efficient to apply to double-circuit lines since the mutual impedance is not considered. The error in case 2 is still greater than the propose ...
balun basics primer
... challenge. In general Marki baluns can be divided into two types. Those with magnetic coupling perform below 10 MHz, while those with only capacitive coupling have low end performance limited to about 1 GHz, but can operate up to millimeter wave frequencies. Phase Balance: The most important perform ...
... challenge. In general Marki baluns can be divided into two types. Those with magnetic coupling perform below 10 MHz, while those with only capacitive coupling have low end performance limited to about 1 GHz, but can operate up to millimeter wave frequencies. Phase Balance: The most important perform ...
DDC, CDC, SMS Series: Zero Bias Silicon Schottky Barrier Detector Diodes Applications Features
... Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in ...
... Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in ...
Design and simulation of meander line antenna
... storage of electrical energy and loss. The overall conductor length affects the inductance. Higher the number of turns the smaller the bandwidth. The number of turns will affect the return loss performance. More turns better performance. ...
... storage of electrical energy and loss. The overall conductor length affects the inductance. Higher the number of turns the smaller the bandwidth. The number of turns will affect the return loss performance. More turns better performance. ...
User’s Manual Model 701923 PBD2000 Differential Probe
... These probes are not so well known, but they have been used with measuring instruments having 50 Ω inputs for a relatively long time. The probe head has a special built-in 450 Ω or 950 Ω resistor, designed for high frequency, and uses a 50 Ω coaxial cable. It is still very popular to this day since ...
... These probes are not so well known, but they have been used with measuring instruments having 50 Ω inputs for a relatively long time. The probe head has a special built-in 450 Ω or 950 Ω resistor, designed for high frequency, and uses a 50 Ω coaxial cable. It is still very popular to this day since ...
Aalborg Universitet EHV/HV Underground Cable Systems for Power Transmission Bak, Claus Leth
... Hammer Bakker December 2014. ...
... Hammer Bakker December 2014. ...
Nominal impedance
Nominal impedance in electrical engineering and audio engineering refers to the approximate designed impedance of an electrical circuit or device. The term is applied in a number of different fields, most often being encountered in respect of:The nominal value of the characteristic impedance of a cable or other form of transmission line.The nominal value of the input, output or image impedance of a port of a network, especially a network intended for use with a transmission line, such as filters, equalisers and amplifiers.The nominal value of the input impedance of a radio frequency antennaThe actual impedance may vary quite considerably from the nominal figure with changes in frequency. In the case of cables and other transmission lines, there is also variation along the length of the cable, if it is not properly terminated. It is usual practice to speak of nominal impedance as if it were a constant resistance, that is, it is invariant with frequency and has a zero reactive component, despite this often being far from the case. Depending on the field of application, nominal impedance is implicitly referring to a specific point on the frequency response of the circuit under consideration. This may be at low-frequency, mid-band or some other point and specific applications are discussed in the sections below.In most applications, there are a number of values of nominal impedance that are recognised as being standard. The nominal impedance of a component or circuit is often assigned one of these standard values, regardless of whether the measured impedance exactly corresponds to it. The item is assigned the nearest standard value.