• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SPEED VARIATOR INDUSTRIAL DRIVE SYSTEMS
SPEED VARIATOR INDUSTRIAL DRIVE SYSTEMS

... is located in the base near the left end. Entrance of conduit through other than the left end of the base or top may be blocked by base mounted components or top mounted blower. ...
LADI Analog-Digital Interface
LADI Analog-Digital Interface

... Installation and Operator Instructions .............................................................................................................................. 3  WEEE .............................................................................................................................. ...
Electronics 3 Class 16 Before the availability of high power
Electronics 3 Class 16 Before the availability of high power

... Electronics 3 Class 16 Before the availability of high power electronics, most speed control of electric motors involved DC motors somewhere. However AC induction motors have advantages - No commuter of friction slip connectors - Easier to manufacture. - Less Maintenance (Brushes) - (No sparks) - Sm ...
Automatic Power Factor Correction by Continuous Monitoring
Automatic Power Factor Correction by Continuous Monitoring

... available in department. I would also like to thanks to my guide Mr. U.E Hiwase For his useful guidance and for helping me to carrying out my project successfully. ...
protection_from_ligh..
protection_from_ligh..

... – Electronic circuits damaged by high current or voltage caused by that current. • If lightning occurs near an overhead electric or telephone line, large current induced or injected into the line. • Charge can also be injected into soil. Arcing to nearby buried conductors at distances up to 100 m. ...
Modeling and Real-Time Simulation of a Doubly
Modeling and Real-Time Simulation of a Doubly

... The wind turbine and the doubly-fed induction generator are shown in Fig. 1. The AC/DC/AC converter is divided into two components: the rotor-side converter (Crotor) and the grid-side converter (Cgrid). Crotor and Cgrid are Voltage-Sourced Converters that use forced-commutated power electronic devic ...
Ferroresonance in Voltage Transformer (VT)
Ferroresonance in Voltage Transformer (VT)

Wires and Cables document
Wires and Cables document

... The following diagrams illustrate how to get increased current (more power) by using parallel wiring and how to increase voltage levels by using series wiring. You can do both using series and parallel wiring in combinations. ...
Electricity and Magnetism
Electricity and Magnetism

SMPD Product Brief - IXYS Power
SMPD Product Brief - IXYS Power

... A ceramic isolation of up to 4.5kV is achieved with the Direct Copper Bond (DCB) substrate technology – an electrically isolated tab is provided for heat sinking. The DCB provides low thermal impedance and best-in-class power and temperature cycling capabilities. The ISOPLUS™ advantage also facilita ...
full abstracts in word format
full abstracts in word format

... The development of power semiconductors, especially IGBT's has led to the small power HVDC transmission based on Voltage Source Converters (VSCs). The VSC based HVDC installations has several advantages compared to conventional HVDC such as, independent control of active and reactive power, dynamic ...
SINGLE PHASE CURRENT SOURCE INVERTER (C.S.I)
SINGLE PHASE CURRENT SOURCE INVERTER (C.S.I)

... properly a low buzz will be heard from the DC line chowk). 2. Clip ground lead of oscilloscope to X and the two line leads to Y and Z. Trace *1 gives load voltage and trace *2 the voltage across the Thyristor Th1 . 3. Switch both the waveform in details. 4. Adjust oscilloscope concentrate on the tur ...
rt41LURES IN THREE-PHASE STATOR WINDINGS
rt41LURES IN THREE-PHASE STATOR WINDINGS

... insulation in all phases of the stator winding typically is caused by load demands exceeding the rating of the motor. NOTE: Under-voltage and over-voltage (exceeding NEMA standards) will result in the same type of insulation deterioration. ...
Control for Grid Connected Small Wind Turbine System
Control for Grid Connected Small Wind Turbine System

File - Mrmegaro.com
File - Mrmegaro.com

Final Presentation
Final Presentation

... Photovoltaic (PV) solar arrays can be used to power mobile devices; however, solar array output power is non-constant and most mobile device chargers require a constant voltage and current source. Team dec1013 purposed building a MPS that would supply a constant voltage and current to mobile devices ...
Connecting Converters in Parallel
Connecting Converters in Parallel

DIESEL GENERATOR SET
DIESEL GENERATOR SET

BR044426429
BR044426429

... divided into two distinct stages: one stage is used for logic evaluation; the other stage is used to reset the gate output logic value. 1. Conventional Switching There are three major sources of power dissipation in digital CMOS circuits those are dynamic, short circuit and leakage power dissipation ...
2015 Power transformers design and analysis with Flux SG CN67
2015 Power transformers design and analysis with Flux SG CN67

Energy transfer in an electric circuit
Energy transfer in an electric circuit

... Energy is conserved, so the energy transferred from chemical to electrical by the emf of the cell must ‘pay’ for the energy transferred to other forms in the circuit - this is the sum of the energy transferred in the cell itself and the energy transferred by the external load. ...
High/Low Voltage Disconnect Test Procedure
High/Low Voltage Disconnect Test Procedure

... 1. Test Name: High/Low Voltage Disconnect Test Author: Andrew and Xiaolong The high voltage disconnect is integrated to protect the battery from overcharging and low voltage disconnect is integrated to disconnect the USB and fan so the battery will have enough power to restart the system for one hou ...
PRC-023-1 * Transmission Relay Loadability
PRC-023-1 * Transmission Relay Loadability

... R1.4. Set transmission line relays on series compensated transmission lines so they do not operate at or below the maximum power transfer capability of the line, determined as the greater of: - 115% of the highest emergency rating of the series capacitor. - 115% of the maximum power transfer capabil ...
A Tariff for Reactive Power
A Tariff for Reactive Power

increase of the grid integration of decentralized power plants by the
increase of the grid integration of decentralized power plants by the

... evolves when VRDT are integrated in power generating units and plants. In such application it is beneficial for the manufacturer of the PGU to use a simple component with integrated control function which improves operating ranges of the entire PGU and thus stringent grid code requirements can be fu ...
< 1 ... 905 906 907 908 909 910 911 912 913 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report