• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Evaluates:  MAX9940 MAX9940 Evaluation Kit General Description Features
Evaluates: MAX9940 MAX9940 Evaluation Kit General Description Features

... Enables the MAX9940 using the MAXQ2000’s GPIO pin, which is used for power saving. Power is only applied when the START pushbutton (SW2) is pressed. Power is disabled when the MAXQ2000 is done communicating with the DS2413. Before changing shunt positions, press the STOP pushbutton (SW3). Note: The ...
Power and Failure Analysis of CAM Cells Due to
Power and Failure Analysis of CAM Cells Due to

... As we move forward into the smaller geometry devices, it’s likely that manufacturing process will be more difficult to control. The manufacturing process causes variations in many different parameters in the device. These variations increase as technology scales due to the difficulty of fabricating ...
- Orion Car Audio
- Orion Car Audio

TEMPUS ENERGY: VOLTAGE DIPS 1: Introduction When
TEMPUS ENERGY: VOLTAGE DIPS 1: Introduction When

LIGHTNING SURGE PROTECTOR FOR THREE
LIGHTNING SURGE PROTECTOR FOR THREE

... *3. For 440V AC three-phase/3-wire system, use a residual current circuit breaker with overcurrent protection. *4. For single-phase/2-wire system, connect lines to terminal 1 and 2 of the MAT2. For single-phase/3-wire system, connect the neutral line to terminal 2 of the MAT2. ...
“Use of FPGA`s in critical space flight applications
“Use of FPGA`s in critical space flight applications

... The WIRE cryostat has four pyrotechnic mechanisms (one on a vent, three on the cover) that need to be fired to properly configure the cryostat for operation in space at the design temperatures. Releasing the cover requires the firing of six initiators on three bolt-release mechanisms. Two initiators ...
56- Electric Latch Retraction Exit Devices Installation and
56- Electric Latch Retraction Exit Devices Installation and

... o Physically disconnect power from rail and confirm that input is off. o *Check for mechanical interference (e.g., warped door, lack of shims, misalignment of rail, etc.). o *Was a motor kit (M56) installed? Verify the rail assembly. Rail behaves abnormally (multiple cycles, clicking, delayed retrac ...
Aalborg Universitet QFT Framework for Robust Tuning of Power System Stabilizers
Aalborg Universitet QFT Framework for Robust Tuning of Power System Stabilizers

... The excitation voltage E fd , is supplied from the exciter and is controlled by the Automatic Voltage Regulator (AVR), to keep the terminal voltage equal to reference voltage. Although the AVR is very effective during steady state operation, it may have a negative influence on the damping of power s ...
systems for street lighting control power reduction
systems for street lighting control power reduction

... The device calculates the hours of sunrise and sunset based on user input geographical coordinates and the date. After installing the driver in a lighting cabinet it is sufficient to validate the date and time, and ...
165-260
165-260

... etc. To avoid any question of how the custom logic interacts with the relay itself, the VTS environment models the entire relay in addition to the custom programming. Unlike other programming environments, the IDEA Workbench does not require the user to have an actual relay or relay test set on hand ...
Decoupling capacitor - Renesas e
Decoupling capacitor - Renesas e

BDTIC C C M - P F C
BDTIC C C M - P F C

... The ICE2PCS06/G is a 8 pin control IC for power factor correction converters. It comes in both DIP and DSO packages and is suitable for wide range line input applications from 85 to 265 VAC. The IC supports converters in boost topology and it operates in continuous conduction mode (CCM) with average ...
Acom 1000 Operation Manual
Acom 1000 Operation Manual

... Before connecting the amplifier to your mains supply, be sure that the supply is correctly wired, and is adequate for the current drawn by the amplifier (up to 10A). Make certain that the grounding lead is connected properly in the wall outlet for the amplifier. It is preferable that you use the wal ...
Application Note for Flyback Converter Using the Primary
Application Note for Flyback Converter Using the Primary

... The MP020-5 is a high performance AC/DC power supply regulator for the cost effective low power charger and adapter applications. It can achieve accurate constant voltage (CV) and tight constant current (CC) regulation without opto-coupler and secondary control circuitry. Meanwhile, it also eliminat ...
Comparison Study of Singly-Fed Electric Machine with Doubly
Comparison Study of Singly-Fed Electric Machine with Doubly

... iq and id components are shown in Fig. 2 a) and b). Due to the strong magnetic field given by the buried rare-earth magnets, IPM motors can be designed more compact than any other types of electric motors with a decent torque capability. For a relatively small speed-torque region, an IPM design can ...
MAX745 Switch-Mode Lithium-Ion Battery-Charger General Description
MAX745 Switch-Mode Lithium-Ion Battery-Charger General Description

... up to the voltage at BST, which is greater than the input voltage while the high-side MOSFET is on. The synchronous rectifier (M1B) behaves like a diode but has a smaller voltage drop, improving efficiency. A small dead time is added between the time when the high-side MOSFET is turned off and when ...
unit2
unit2

Three Phase Cascaded H-Bridge Multilevel Inverter with Ac
Three Phase Cascaded H-Bridge Multilevel Inverter with Ac

... phase legs of the series-chain of H-bridge inverter, which can possibly generate different output voltage waveforms and offers the potential for ac system phase-balancing. This feature is impossible in other Voltage source control topologies utilizing a common dc link. Since this topology consists o ...
BDTIC C C M - P F C
BDTIC C C M - P F C

... The ICE2PCS05/G is a 8 pin control IC for power factor correction converters. It comes in both DIP and DSO packages and is suitable for wide range line input applications from 85 to 265 VAC. The IC supports converters in boost topology and it operates in continuous conduction mode (CCM) with average ...
Motor Protection Voltage Unbalance and Single
Motor Protection Voltage Unbalance and Single

... above its maximum temperature rating will reduce the motor’s expected life by 50%. Operating at 10°C above this, the motor’s life will be reduced again by 50%. This reduction of the expected life of the motor repeats itself for every 10°C. This is sometimes referred to as the “half life” rule. Altho ...
ISSCC 2014 Digest of Technical Papers
ISSCC 2014 Digest of Technical Papers

SG-500 Linear Amplifier
SG-500 Linear Amplifier

Reliability Standard Audit Worksheet CIP-003-AB-5 – Security Management Controls
Reliability Standard Audit Worksheet CIP-003-AB-5 – Security Management Controls

... 4.2.1.1.1. is part of a load shedding program that is subject to one or more requirements in a reliability standard; and 4.2.1.1.2. performs automatic load shedding under a common control system owned by one or more of the entities in subsection 4.2.1, without human operator initiation, of 300 MW or ...
Electrical Safety - HCC Learning Web
Electrical Safety - HCC Learning Web

... Relays can be used to control indoor fan motors, condenser fan motors, damper motors, starting capacitors, and control lockouts. ...
A New Single-Phase Soft-Switching Power Factor Correction
A New Single-Phase Soft-Switching Power Factor Correction

... N RECENT years, the power electronic systems and devices, which are used more frequently, create harmonics current and pollute the electricity network. Harmonics have a negative effect on the operation of the receiver, which is fed from the same network. Nowadays, engineers design all the electronic ...
< 1 ... 252 253 254 255 256 257 258 259 260 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report