• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
v I
v I

User’s Manual P30L LCD 30A Solar Charge Controller
User’s Manual P30L LCD 30A Solar Charge Controller

lecture material on medical sensor design
lecture material on medical sensor design

... the system. For instance, some sensors require +/- 6 V. If a sensor just uses AA or lithium batteries, we need special voltage converters and regulators in order to use this sensor. The power consumption and turn-on times of converters and regulators’ circuitry must be included in the total energy b ...
ZEUS Access - Tiptop Audio
ZEUS Access - Tiptop Audio

... Bus board and a few simple steps, you can now power up a modular system with ease! Residing on the left-most side of your case, the Zeus Access supplies a convienent interface to easily power the Zeus Powered Bus Board system from the external Cincon-TTA laptop-style universal power supply. The Zeus ...
BDTIC P F C - D C M   I... T D A 4 8 6 2 / T D...
BDTIC P F C - D C M I... T D A 4 8 6 2 / T D...

... A one quadrant multiplier is the crucial circuitry that regulates the gate driver with respect of the DC output voltage and the AC haversine input voltage of the preregulator. Both inputs are designed for good linearity over a wide dynamic range, 0 V to 4.0 V for the MULTIN and 2.5 V to 4.0 V for th ...
Data Sheet
Data Sheet

... The EV kit is a fully assembled and tested circuit board that demonstrates the performance of the MAX17681 high-efficiency, iso-buck DC-DC converter designed to provide isolated power up to 3W. The EV kit generates either ±15V, 100mA or ±12V, 50mA output voltages from a 17V to 32V input supply. The ...
Pac Tel Cover
Pac Tel Cover

OFFICE OF THE PRINCIPAL e-mail polyjanjgir@rediffmail.com ,Tel
OFFICE OF THE PRINCIPAL e-mail [email protected] ,Tel

... the stipulated period, in full or part it will be open to the Principal, Government Polytechnic, Janjgir (CG) to recover liquidated damage from the firm at the rate of 2% of the value of undelivered goods per month or part thereof, subject to a maximum of 5% of the value of undelivered goods. Altern ...
view EM-I Question Bank
view EM-I Question Bank

PAM2805 Description Pin Assignments
PAM2805 Description Pin Assignments

... An input capacitor is required to reduce the input ripple and noise for proper operation of the PAM2805. For good input decoupling, Low ESR (equivalent series resistance) capacitors should be used at the input. At least 2.2µF input capacitor is recommended for most applications. A minimum output cap ...
Problem B - Geneva Area City Schools
Problem B - Geneva Area City Schools

... 9. A wind turbine is built to service farmers in England. The turbine is connected to a generator, which can supply a rms current of 1.3 A on a 12 kΩ load. If the rms potential difference is 15.6 kV, find the maximum output emf provided by the wind turbine. Calculate the maximum ac current. How much ...
Prof. Dr-lng. Konstantin Meyl SCALAR WAVE TECHNOLOGY
Prof. Dr-lng. Konstantin Meyl SCALAR WAVE TECHNOLOGY

... The experimentation kit contains additionally a frequency counter as well as four further pancake coils with double or half wire length. The waveform generator is besides in an extended range and in different wave forms adjustable. It is assumed, that primarily physicists, engineers and in the measu ...
Modeling and Control of Electrical Drives
Modeling and Control of Electrical Drives

attention all bidders
attention all bidders

... Abnormal Supply Conditions: If normal ac supply deviates from specified and adjustable voltage, voltage waveform, or frequency limits, the battery supplies energy to maintain constant, regulated inverter ac power output to the load without switching or disturbance. If normal power fails, energy supp ...
- Orion Car Audio
- Orion Car Audio

test to prove de-energised cs-ohs-54
test to prove de-energised cs-ohs-54

... disconnected correctly during the isolation process. (The Test Meter is to be tested on a known power source before & after the test is carried out).  The results of this test for de-energised are to be recorded in the WCD item column.  Utilising a separated /visible break isolation point Accessin ...
FDMF6704V - XS DrMOS FD M
FDMF6704V - XS DrMOS FD M

... The high-side driver (GH) is designed to drive a floating N-channel MOSFET. The bias voltage for the high-side driver is developed by a bootstrap supply circuit, consisting of the internal BOOT diode and an external bootstrap capacitor (CBOOT). During start-up, VSWH is held at PGND, allowing CBOOT t ...
LSM2 Series - power, Murata
LSM2 Series - power, Murata

... ceramic/tantalum output capacitors and a 22µF tantalum input capacitor. These capacitors are necessary to accommodate our test equipment and may not be required to achieve desired performance in your application. The LSM2s are designed with high-quality, high-performance internal I/O caps, and will ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) ISSN: , PP: 55-59 www.iosrjournals.org
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) ISSN: , PP: 55-59 www.iosrjournals.org

... Several types of CMOS STIs have been presented since the emerging of CMOS technology. However, they utilize large off-chip resistors and depletion transistors, which are notsuitable in recent technologies. Some new structures for CMOS analog inverter have been presented, which could be considered as ...
EMI Conducted Interference
EMI Conducted Interference

Elegance Electrician`s Guide
Elegance Electrician`s Guide

Power and Failure Analysis of CAM Cells Due to
Power and Failure Analysis of CAM Cells Due to

... As we move forward into the smaller geometry devices, it’s likely that manufacturing process will be more difficult to control. The manufacturing process causes variations in many different parameters in the device. These variations increase as technology scales due to the difficulty of fabricating ...
Test Point Diagram
Test Point Diagram

... Brief check of POWER MODULE W Usually, they are in a state of being short-circuited if they are broken. Measure the resistance in the following points (connectors, etc.). ...
64WKS_Installation_en-UK_RevA
64WKS_Installation_en-UK_RevA

AP1520
AP1520

... transient characteristics. The PWM control circuit is able to vary the duty ratio linearly from 0 up to 100%. This converter also contains an error amplifier circuit. An enable function, an over current protection and a short circuit protection are built inside, and when OCP or SCP happens, the oper ...
< 1 ... 251 252 253 254 255 256 257 258 259 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report