• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
615-4740 (45-075) Induction Kit
615-4740 (45-075) Induction Kit

... provides the magnetic field needed in motors. TAPPING: this is a connection point somewhere on a coil winding….in a coil of say, 100 turns, every 5th coil may be tapped. It is an allowance is made to connect a circuit at that point. many voltages can be derived from the one wound coil in this way. T ...
Word Version - LHO - LIGO Scientific Collaboration
Word Version - LHO - LIGO Scientific Collaboration

... Many LIGO designs using chassis type implementations can be served with one or two three-pin power feeds. Two such connectors used in the HEPI implementation are shown in Figure 6, Female Power Connector and Figure 7, Male Power Connector. This style connector is available in a filtered version from ...
PDF
PDF

... Turn on the wind tunnel fan motor frequency at 15 Hz by using the thumb wheel and the arrow buttons on the wind tunnel control panel. The thumb wheel is very sensitive, so be careful and do NOT overshoot. This will be the highest speed of your measurements and you need to allow the speed to even ou ...
SIRComm® MiniSIR2® 115.2kbps IrDA®1.0 Transceiver Module
SIRComm® MiniSIR2® 115.2kbps IrDA®1.0 Transceiver Module

... The figure below shows details for correctly positioning MiniSIR2 with respect to the system optical port. One recommended optical port window material (Lexan 101, 141 or 920A) can be obtained from General Electric Plastics (U.S.A.) Tel: 1-800-845-0600 or Fax: 1-413-448-7731. The dye used for the op ...
Parallel Operation and Standby Service Schedule Designation R3
Parallel Operation and Standby Service Schedule Designation R3

... The Customer taking service under this rider shall maintain and furnish current evidence of comprehensive general liability insurance in the amount of $2,500,000 per occurrence. This insurance can be a combination of primary and excess insurance. The Company shall be named as an additional insured u ...
DU-45MV 50/100/200mV DC Full Scale 4 1/2 Digit with 0.56” LEDs
DU-45MV 50/100/200mV DC Full Scale 4 1/2 Digit with 0.56” LEDs

... WARNING: AC and DC input signals and power supply voltages can be hazardous. Do Not connect live wires to screw terminal plugs, and do not insert, remove or handle screw terminal plugs with live wires connected. ...
Design of Low Voltage, Low Power, Wide Input Range Fully CMOS
Design of Low Voltage, Low Power, Wide Input Range Fully CMOS

EVBUM2175 - 3.6 W Flyback 3 LED Step Dimmable Driver
EVBUM2175 - 3.6 W Flyback 3 LED Step Dimmable Driver

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marki ...
1.5 A 280 kHz/560 kHz Boost Regulators
1.5 A 280 kHz/560 kHz Boost Regulators

... Boost Regulators The CS5171/2/3/4 products are 280 kHz/560 kHz switching regulators with a high efficiency, 1.5 A integrated switch. These parts operate over a wide input voltage range, from 2.7 V to 30 V. The flexibility of the design allows the chips to operate in most power supply configurations, ...
A Dual-Output Integrated LLC Resonant Controller and LED
A Dual-Output Integrated LLC Resonant Controller and LED

... The advantage of LLC resonant converters is that they can reduce the switching loss and noise since switching components are softly commutated based on the resonant technique. Also, they can detect the load variation efficiently since a large voltage gain can be obtained with a small switching frequ ...
CA320005EN
CA320005EN

DS1834/A/D Dual EconoReset with Pushbutton FEATURES PIN ASSIGNMENT
DS1834/A/D Dual EconoReset with Pushbutton FEATURES PIN ASSIGNMENT

... All versions of the DS1834 can maintain valid outputs as long as one input remains above 1.2 volts. However, the RST outputs on the DS1834 use a push-pull output structure which can maintain a valid output below 1.2 volts. To sink current below 1.2 volts a resistor can be connected from RST to GND ( ...
ARM General Purpose Processor
ARM General Purpose Processor

FAN6754B Highly Integrated Green- Mode PWM Controller FAN6754B — Highly Integrated
FAN6754B Highly Integrated Green- Mode PWM Controller FAN6754B — Highly Integrated

... through an external diode and resistor; RHV, (1N4007 / 200KΩ recommended). Peak startup current drawn from the HV pin is (VAC× 2 ) / RHV and charges the hold-up capacitor through the diode and resistor. When the VDD capacitor level reaches VDD-ON, the startup current switches off. At this moment, th ...
Aalborg Universitet Distributed Active Synchronization Strategy for Microgrid Seamless Reconnection to
Aalborg Universitet Distributed Active Synchronization Strategy for Microgrid Seamless Reconnection to

... DR units and dispersed loads, which can operate in both gridconnected and islanded modes [1]. In order to guarantee uninterruptible and reliable power supply, a smooth transition from islanded to grid-connected modes is required. To achieve this goal, it is necessary to synchronize microgrid voltage ...
Rotor side control of grid-connected wound rotor induction machine
Rotor side control of grid-connected wound rotor induction machine

... The speed of a cage rotor induction machine is primarily determined by the supply frequency. The short-circuited rotor offers very low resistance and the nominal slip is within 5%. In the case of a wound rotor induction machine it is possible to introduce additional resistance in the rotor circuit a ...
AN4721, S12ZVH: Hardware Design Guidelines
AN4721, S12ZVH: Hardware Design Guidelines

G690/G691
G690/G691

... 140ms min Power-On Reset Pulse Width 10µA Supply Current Guaranteed Reset Valid to VCC = +1V Power Supply Transient Immunity No External Components 3-Pin SOT-23 and SC-70-3(SOT-323) Packages ...
Type here the title of your Paper
Type here the title of your Paper

... The LMSCWs with low values of inductivity and high transport currents can find application in superconducting electric power equipment: power windings of DC and AC electrical rotating machines, superconducting transformers, superconducting cables for DC and AC power transmission lines, superconduct ...
methods to enhance optical performance of lenticular lens
methods to enhance optical performance of lenticular lens

N044086772
N044086772

... Micro Electro Mechanical switches are the switches that operates with the laws of mechanical motion. Main advantages are their zero OFF-current and their fast switching behavior. MEMS switches behaves as perfect switches with very low ON resistance and infinite OFF resistance and hence can be used t ...
VI-HAM™, VE-HAM
VI-HAM™, VE-HAM

... AC mains and the DC output voltage of the HAM. P/OK is asserted (active low) when the output bus voltage is within normal operating range (>270 Vdc) and 20 – 25 ms after DC-DC converters are enabled by the E/O signal of the HAM. This provides sufficient time for the converters to turn on and their o ...
SPECIFIC FAN POWER
SPECIFIC FAN POWER

... rate, resistance of ventilation system and efficiency of fan system. These are main parameters that have influence on SFP. By stipulating a maximum SFP, it is possible to limit the power requirements for transporting air for entire building, AHUs and individual fans and thus to obligate engineers to ...
2.3 COMPONENT OPERATION 2.3.1 Photovoltaic Cells 2.3.2
2.3 COMPONENT OPERATION 2.3.1 Photovoltaic Cells 2.3.2

... brakes to make it move faster. It is almost always more cost effective to use an adequate wire size, rather than to overcome voltage drop problems with more costly 44 cell modules. Section 2.5.5 discusses maximum power point trackers. These devices are used to bring the module to a point as close as ...
Paper Link - UIC - University of Illinois at Chicago
Paper Link - UIC - University of Illinois at Chicago

... With regard to an isolated inverter, several topological configurations have been proposed to achieve fuel-cell power conversion at high efficiency without incurring high cost [1]–[10]. Based on where the transformer is inserted for isolating the stack from the load, these topologies can be broadly ...
< 1 ... 254 255 256 257 258 259 260 261 262 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report