• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
1730  Calibration Manual Energy Analyzer
1730 Calibration Manual Energy Analyzer

Product Specifications: CLS-EXP-DIM
Product Specifications: CLS-EXP-DIM

... Lighting System (CLS-C6 series) and other Crestron® lighting dimmers to support 120, 230, or 277 Volt loads up to 16 Amps. It allows any output channel of the iLux system to dim a fully loaded circuit of LED[1], incandescent, magnetic low-voltage, neon/cold cathode, or 2-wire dimmable fluorescent li ...
BU7245HFV
BU7245HFV

... Then input terminal voltage is set to more than VSS. (Note 4) An excessive input current will flow when input voltages of more than VDD+0.6V or less than VSS-0.6V are applied. The input current can be set to less than the rated current by adding a limiting resistor. Caution: Operating the IC over th ...
Design, Analysis, and Construction of an Equal Split Wilkinson
Design, Analysis, and Construction of an Equal Split Wilkinson

... or be isolated from, the signal at another port. For a three port power divider, isolation between output ports two and three is important for reducing cross-talk that can be caused by coupling between the ports. In the S-matrix, the elements S23 and S32 are associated with the isolation between the ...
10kV SiC-based Isolated DC-DC Converter for Medium Voltage
10kV SiC-based Isolated DC-DC Converter for Medium Voltage

... be highlighted [3, 4]. This problem has been mainly tackled by synthesizing multi-cellular SST concepts based on modules rated for a fractional portion of the total MV side voltage and performing a series connection of these modules at the input side [2, 5]. The development of Silicon-Carbide (SiC) ...
Dist Training materials HK & China Jun 07 Ver3.0
Dist Training materials HK & China Jun 07 Ver3.0

Minutes of CMS FED Design Meeting Wednesday November 6th 2002
Minutes of CMS FED Design Meeting Wednesday November 6th 2002

... 18. The resistor values for TMS & TCK clock termination are 62R. This value will have to be recalculated if the PCB is changed to 14 layers. The new value of xxx is used for the following resistors: R1144, R1145, R1146, R1147, R1199, and R1201. 19. Add potential divider to the JTAG chain for the QDR ...
Estimation of Zero-Sequence Impedance of Undergrounds Cables for Single-Phase Fault Location
Estimation of Zero-Sequence Impedance of Undergrounds Cables for Single-Phase Fault Location

... Traditionally, fault location techniques have been developed for transmission electric lines due to the impact that faults would have on these kinds of lines. More recently, distribution lines have been taken more into account due to the improvement in the quality of power supply, derived from opera ...
Mitsubishi Heavy Industries
Mitsubishi Heavy Industries

... coating gives one of the methods leading new protection. However, it seems that aluminum coating needs to be improved to a slight degree. Author have done various examinations, in order to investigate the damage mechanism of a FRP blade. In a paper, while explaining the mechanism of damage to a FRP ...
EE-26 - International Journal of Advance Research and Innovation
EE-26 - International Journal of Advance Research and Innovation

High-voltage vacuum Contactors
High-voltage vacuum Contactors

... Consistent with its dedication to the most advanced vacuum technology, Toshiba offers new series of High-voltage vacuum contactors. By adopting an electronics controlled circuit and being designed compactly to ensure reliability, handling ease and safety, the new series of High-voltage Vacuum Contac ...
Institutionen för systemteknik Department of Electrical Engineering Scavenging
Institutionen för systemteknik Department of Electrical Engineering Scavenging

... Nyckelord Keywords Energy Scavenging, Rectifier ...
P83933
P83933

... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can rad ...
Circuits for multiple valued logic—A tutorial and appreciation
Circuits for multiple valued logic—A tutorial and appreciation

... designers in the multi-valued area[l]A large variety of techniques and technologies have been exploited or are about to be. We have seen recent offerings, of direct interest to the multi-valued discipline, of the multiemitter bipolar technology of Transistor-Transistor Logic (T2L), of variations of ...
AAT4616A 数据资料DataSheet下载
AAT4616A 数据资料DataSheet下载

... Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. ...
Aalborg Universitet Microgrids
Aalborg Universitet Microgrids

... components over AC or DC power lines as communication signals to achieve power management among converters. They attract much attention since the coordinated signals (i.e. SoC of ESS, power generation of RES) can be exchanged depend on power lines instead of using external fast communication links. ...
MAX8740 TFT-LCD Step-Up DC-DC Converter General Description Features
MAX8740 TFT-LCD Step-Up DC-DC Converter General Description Features

... TFT-LCD Step-Up DC-DC Converter The equations used here include a constant LIR, which is the ratio of the inductor peak-to-peak ripple current to the average DC inductor current at the full load current. The best trade-off between inductor size and circuit efficiency for step-up regulators generally ...
Lecture_IM
Lecture_IM

... with the speed voltages divided by the shaft speed in mechanical radian per second. The speed voltage terms associated with the rotor: vdr _ speed _ voltage   s s  qr vqr _ speed _ voltage  s s  dr ...
DNLS350E Features Mechanical Data
DNLS350E Features Mechanical Data

... hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by on ...
Simulation of Switching Converters Using Linear Capacitor
Simulation of Switching Converters Using Linear Capacitor

MC13783 Buck and Boost Inductor Sizing
MC13783 Buck and Boost Inductor Sizing

... the use of a smaller inductor value. However, operating at a higher frequency generally results in lower efficiency because of increased internal gate charge losses. For a given switching frequency, the highest inductor current ripple occurs at maximum input voltage and maximum output voltage. The f ...
Predictive-flow-queue based energy
Predictive-flow-queue based energy

... high frame-rate data processing and low-latency access for the frame data. However, these trends also are translated into higher power density, higher operating temperature, and consequently lower system reliability. The power consumption of the gigabit Ethernet controller increases rapidly with the ...
HOW TO VERIFY LIGHTNING PROTECTION EFFICIENCY FOR ELECTRICAL SYSTEMS?
HOW TO VERIFY LIGHTNING PROTECTION EFFICIENCY FOR ELECTRICAL SYSTEMS?

VWR® Mini Gel
VWR® Mini Gel

... 1. Make sure the power supply is turned off 2. Plug the male ends of the black (-) and red (+) electrodes into the jacks on the side of the power supply. 3. After the samples have been loaded into the gel, place the lid over the unit so that the lid covers align with the tank. Set the lid straight d ...
Check System
Check System

< 1 ... 233 234 235 236 237 238 239 240 241 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report