• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
High average power fundamental input couplers for the Cornell
High average power fundamental input couplers for the Cornell

... In this section we describe tools that we use in assisting fundamental RF coupler development. Multipacting might be one of the major RF system performance limiting factors. Multipacting phenomena in coaxial couplers can be studied with MultiPac [14] software package, which became recently available ...
BDTIC www.BDTIC.com/infineon Wireless Components ASK/FSK Transmitter 868/433 MHz
BDTIC www.BDTIC.com/infineon Wireless Components ASK/FSK Transmitter 868/433 MHz

... All Rights Reserved. Attention please! As far as patents or other rights of third parties are concerned, liability is only assumed for components, not for applications, processes and circuits implemented within components or assemblies. The information describes the type of component and shall not b ...
application sizing guide
application sizing guide

... product will be appropriate. Other times, motor options or the features of the servo drive amplifier may dictate the type of motor chosen. In many applications however, either motor type might meet the need. The decision of which to choose could then be made based on cost or maintenance issues. DC b ...
MAX1637 Miniature, Low-Voltage, Precision Step-Down Controller General Description
MAX1637 Miniature, Low-Voltage, Precision Step-Down Controller General Description

... cost, size, and efficiency, while staying within the worstcase specification limits for stress-related parameters such as capacitor ripple current. Do not change the circuit’s switching frequency without first recalculating component values (particularly inductance value at maximum battery voltage). ...
Low-Drift, Low-Power, Dual-Output, VREF and VREF / 2 Voltage
Low-Drift, Low-Power, Dual-Output, VREF and VREF / 2 Voltage

... space, while reducing the cost of the system as compared to a discrete solution. Extremely low dropout voltage of only 10 mV allows operation from very low input voltages, which can be very useful in battery-operated systems. Both the VREF and VBIAS voltages have the same excellent specifications an ...
REF3240-EP 数据资料 dataSheet 下载
REF3240-EP 数据资料 dataSheet 下载

... Supply voltages below the specified levels can cause the REF32xx to momentarily draw currents greater than the typical quiescent current. This momentary current draw can be prevented by using a power supply with a fast rising edge and low output impedance. For optimal startup when the IN pin and ENA ...
BE01416521657.121
BE01416521657.121

... transistor. The early voltage is measured by obtaining the output characteristics of the transistor for different values of base current. The set of current lines obtained from the output characteristics are extended into the second quadrant and gathered in one single point on the VCE axis and this ...
- UTas ePrints
- UTas ePrints

... to the utility and the rotor circuit via partial scale back-to-back voltage source converters (VSCs) connected to the network. In the case of grid faults, transient over-currents flow from the rotor circuit towards the rotor side converter (RSC). These over-currents can either trip out the DFIG or d ...
A.D. Sagneri, D.I. Anderson, and D.J. Perreault, “Optimization of Integrated Transistors for Very High Frequency dc-dc Converters,” IEEE Transactions on Power Electronics , Vol. 28, No. 7, pp. 3614-3626, July 2013.
A.D. Sagneri, D.I. Anderson, and D.J. Perreault, “Optimization of Integrated Transistors for Very High Frequency dc-dc Converters,” IEEE Transactions on Power Electronics , Vol. 28, No. 7, pp. 3614-3626, July 2013.

... sets the minimum device area necessary to process a given amount of power. In contrast to conduction loss, the frequency-dependent losses behave differently from the hard-switching case. With overlap and capacitive discharge mitigated, what remains in terms of switching loss is the circulating curre ...
Transient Power Drop on Timing
Transient Power Drop on Timing

... Steady-State AC Response ...
Atmel ATA6824C High Temperature H-bridge Motor Driver Features DATASHEET
Atmel ATA6824C High Temperature H-bridge Motor Driver Features DATASHEET

... 5V/3.3V VCC Regulator The 5V/3.3V regulator is fully integrated on-chip. It requires only a 2.2µF ceramic capacitor for stability and has 100 mA current capability. Using the VMODE pin, the output voltage can be selected to either 5V or 3.3V. Switching of the output voltage during operation is not i ...
AntMiner S9 Installation Guide
AntMiner S9 Installation Guide

... improvements,  and  other  changes  to  its  products  and  services  at  any  time  and  to  discontinue  any  product   or  service  without  notice.   Customers  should  obtain  the  latest  relevant  information  before  placing  orders ...
RL Line/Load Reactors
RL Line/Load Reactors

... Multiple drives or inverters on a common power line require one reactor per controller. Individual reactors provide filtering between each controller (reducing crosstalk) and also provide optimum surge protection for each unit. A single reactor serving several controllers does not provide adequate p ...
MK Dimming Compatibility Guide
MK Dimming Compatibility Guide

... Dimming lamps require a reduction of the power into the device to produce a reduction of the intensity of the light source. As well as dimming for comfort or effect, by using low energy lamps together with a dimming functionality, you can significantly reduce energy costs within a building. With man ...
a performance comparison of low power lfsr structures
a performance comparison of low power lfsr structures

smart voltage reduction
smart voltage reduction

...  Typically when entering reduction, all switched capacitors will close as the voltage is reduced (assumed voltage control)  This may cause circuits to be leading when in reduction  When leaving reduction, some of the capacitors need to be switched off to get back to unity power factor ...
On the selection and installation of surge protection devices in a TT
On the selection and installation of surge protection devices in a TT

... success of a network of surge protection depends on several factors; the current handling capacity is one of the important parameters. Also note that the values in the Table 1 are the current handling capacity of each SPD connected between a line and the neutral. The SPD between the neutral and eart ...
AAT2608 数据资料DataSheet下载
AAT2608 数据资料DataSheet下载

... own independent enable pin. All LDOs have a fixed output programmed during manufacturing. Each LDO consumes 30µA of quiescent current and is stable with a small 1.0μF ceramic output capacitor. These LDOs offer high power supply rejection and provide over-current and over-temperature protection. ...
BD8964FVM
BD8964FVM

Detection of back-fed ground fault using smart grid distribution
Detection of back-fed ground fault using smart grid distribution

... are more difficult to detect and isolate. In more than two decades different research and studies have been done on the matter, but there is still no definitive reliable solution, used by electric utilities, to detect a single broken conductor in the distribution system with or without ground connec ...
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems
8.3 Onsite Power System 8.3.1 Alternating Current Power Systems

... difference to limit motor torque during the transfer. The NPSS major distribution switchgear and nominal bus voltages are shown in Table 8.3-3—Normal Power Supply System Switchgear and Load Center Numbering and Nominal Voltage. The NPSS is configured in four trains, supplying the Turbine Island (TI) ...
BD14000EFV-C Datasheet
BD14000EFV-C Datasheet

... VREG output voltage is used as I/F power supply and control power supply for the chip’s internal blocks. It is assumed that up to 10mA maximum is applied as external load, and since it is a basic simple power supply, it can only apply power to I/F. Please use only after a thorough inspection of elec ...
LV_Power_MOSFET - Renesas E
LV_Power_MOSFET - Renesas E

... off, the magnetic field of the inductor induces a counter electromagnetic force, EMF, that can build up a high VDS voltage across the MOSFET. The full buildup of this induced voltage may exceed the rated breakdown voltage, VDSS, of the MOSFET and result in the catastrophic failure of the MOSFET. Two ...
Evaluation Board User Guide UG-116
Evaluation Board User Guide UG-116

... (“ADI”), with its principal place of business at One Technology Way, Norwood, MA 02062, USA. Subject to the terms and conditions of the Agreement, ADI hereby grants to Customer a free, limited, personal, temporary, non-exclusive, non-sublicensable, non-transferable license to use the Evaluation Boar ...
CP2102/9 - Silicon Labs
CP2102/9 - Silicon Labs

... String, Power Descriptor, Device Release Number, and Device Serial Number as desired for OEM applications. The programmable ROM is programmed on-board via the USB, allowing the programming step to be easily integrated into the product manufacturing and testing process. Royalty-free Virtual COM Port ...
< 1 ... 176 177 178 179 180 181 182 183 184 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report