• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NCP1251 - ONSemi
NCP1251 - ONSemi

... NCP120X series success, the NCP1251 packs all the necessary components normally needed in today modern power supply designs, bringing several enhancements such as a non−dissipative OPP. • Current−mode operation with internal ramp compensation: Implementing peak current mode control at a fixed 65 kHz ...
BD6968FVM
BD6968FVM

... Connecting of the power supply in reverse polarity can damage IC. Take precautions when connecting the power supply lines. An external direction diode can be added. Power supply line Back electromotive force causes regenerated current to power supply line, therefore take a measure such as placing a ...
BASIC ELECTRICAL MATERIALS AND METHODS 260500
BASIC ELECTRICAL MATERIALS AND METHODS 260500

... Asbestos: No asbestos-containing materials have been identified on items that are indicated to be disturbed. If asbestos-containing materials are encountered, comply with the following: Upon encountering any previously unidentified materials which he suspects may contain asbestos, the Contractor sha ...
Accurate Fault Location Algorithm on Power Transmission Lines
Accurate Fault Location Algorithm on Power Transmission Lines

... line. Such a technique [2] is simple and does not require communication means with the remote end. Therefore, it is attractive and is commonly incorporated into the microprocessor-based protective relays. However, it is subject to several sources of error, such as the reactance effect, the line shun ...
PDF
PDF

... able to digital impulses. Inside A/D alteration process, it is necessary to be able to 1st small sample the actual insight. That tested indication can be than placed on combining comparators to determine the digital equivalent from the analog indication. [1].A comparator is a circuit that compares t ...
uss dry type transformer
uss dry type transformer

Accurate Fault Location Algorithm on Power Transmission Lines
Accurate Fault Location Algorithm on Power Transmission Lines

... line. Such a technique [2] is simple and does not require communication means with the remote end. Therefore, it is attractive and is commonly incorporated into the microprocessor-based protective relays. However, it is subject to several sources of error, such as the reactance effect, the line shun ...
chapter 18-electricity
chapter 18-electricity

The latest Soft-Starter Technology
The latest Soft-Starter Technology

Electrical safety code of practice 2010 - Works
Electrical safety code of practice 2010 - Works

... This Code of Practice on how to manage risks associated with electricity entity works is made under section 44 of the ES Act. A code of practice is a practical guide to achieving the standards of electrical safety required under the ES Act and the Electrical Safety Regulation 2013 (the ES Regulation ...
GEM Plus - GE Industrial Solutions
GEM Plus - GE Industrial Solutions

PAM2306D Description Pin Assignments
PAM2306D Description Pin Assignments

... In continuous mode, the source current of the top MOSFET is a square wave of duty cycle VOUT/VIN. To prevent large voltage transients, a low ESR input capacitor sized for the maximum RMS current must be used. The maximum RMS capacitor current is given by: ...
Introduction to Motor Starting Analysis
Introduction to Motor Starting Analysis

A Portable 2-Transistor Picowatt Temperature
A Portable 2-Transistor Picowatt Temperature

... power consumption [13]–[15]. Finally, storing and refreshing a voltage at a floating node can be used to supply a reference voltage [16], [17]. However, these voltage references do not meet the demanding low power consumption, small design area, and low functional supply voltage requirements of mini ...
- Macquarie University ResearchOnline
- Macquarie University ResearchOnline

... Figure 2 GaN MOSFET on Si/SiC [2]................................................................................... 3 Figure 3 Buck converter ........................................................................................................ 3 Figure 4 Boost converter.......................... ...
DC Motors Introduction D.C. motors are seldom used in ordinary
DC Motors Introduction D.C. motors are seldom used in ordinary

Table of Contents Power Management
Table of Contents Power Management

DC Motors Introduction D.C. motors are seldom used in ordinary
DC Motors Introduction D.C. motors are seldom used in ordinary

... windage losses. Therefore, the armature current Ia is small and the back e.m.f. Is nearly equal to the applied voltage. (ii) If the motor is suddenly loaded, the firest effect is to cause the armature to slow down. Therefore, the speed at which the armature conductors move throug the field is reduce ...
Monitoring Devices SENTRON Answers for infrastructure and cities. Configu-
Monitoring Devices SENTRON Answers for infrastructure and cities. Configu-

gei50261 - GE Grid Solutions
gei50261 - GE Grid Solutions

... motors will continue to run on single-phase power. At this time, the voltage unbalance will be small since the motors maintain nearly full voltage across the open phase and a sensitive voltage unbalance relay is required to detect the single-phase operation. Since the motors will overheat and be dam ...
LTC4059
LTC4059

... rises approximately 150mV above the BAT pin voltage, a program resistor is connected from the PROG pin to ground, and the EN pin is pulled below the shutdown threshold (typically 0.85V). If the BAT pin voltage is below 4.2V, or the Li CC pin is pulled above VLi CC (LTC4059 only), the LTC4059 will ch ...
Data Debugging in Power System Operations Using Gap Statistic A
Data Debugging in Power System Operations Using Gap Statistic A

... adopted instead. For a motor drive powered by mains, one can apply SMR [27] as a front-end AC/DC converter to accomplish this task. Meanwhile, good line drawn power quality can be obtained simultaneously. Till now, there were a lot of SMRs, the surveys for single-phase SMRs can be found in [28,29]. ...
AN-EVAL3AR2280JZ
AN-EVAL3AR2280JZ

... a 5V, 20W power supply that operates from an AC line input voltage range of 85Vac to 282Vac and brownout detect/reset voltage is 75/85Vac, suitable for applications in enclosed adapter or open frame auxiliary power supply for different system such as PC, server, DVD, LED TV, Set-top box, etc. ...
BD9A101MUV-LB
BD9A101MUV-LB

... Synchronous Single DC/DC Converter. SLLMTM (Simple Light Load Mode)Control. ...
ion laser technology ilt5000 operations manual revision b 45-052
ion laser technology ilt5000 operations manual revision b 45-052

< 1 ... 178 179 180 181 182 183 184 185 186 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report