DC1646A LTC5564 15GHz RF Power Detector with Comparator
... for applications at frequencies of 5.8GHz and 15GHz. It has better than 15dB return loss at these targeted frequencies. The input dynamic range at 5.8GHz is 40dB (from –24dBm to 16dBm) and slightly lower sensitivity at 15GHz. Comparator The high speed comparator compares the external reference volta ...
... for applications at frequencies of 5.8GHz and 15GHz. It has better than 15dB return loss at these targeted frequencies. The input dynamic range at 5.8GHz is 40dB (from –24dBm to 16dBm) and slightly lower sensitivity at 15GHz. Comparator The high speed comparator compares the external reference volta ...
Aalborg Universitet Liu, Yan
... feed into an AC system with the short electrical distance. And consequently, a so-called Multi-Infeed Direct Current (MIDC) transmission system is formed. On the other hand, as the fast growing of wind power in electrical grids, the Voltage Source Converter based HVDC (VSC-HVDC) links have becoming ...
... feed into an AC system with the short electrical distance. And consequently, a so-called Multi-Infeed Direct Current (MIDC) transmission system is formed. On the other hand, as the fast growing of wind power in electrical grids, the Voltage Source Converter based HVDC (VSC-HVDC) links have becoming ...
Power Measurement Techniques For Nonsinusoidal conditions
... power factor one, the DSWM has an estimated uncertainty (2σ) of 60 ppm at 50 Hz and 600 ppm at 20 kHz. The wattmeter has also participated in three international comparisons with satisfactory results. The most important additional feature, the input distortion, has been verified to be less than 800 ...
... power factor one, the DSWM has an estimated uncertainty (2σ) of 60 ppm at 50 Hz and 600 ppm at 20 kHz. The wattmeter has also participated in three international comparisons with satisfactory results. The most important additional feature, the input distortion, has been verified to be less than 800 ...
Computer interfacing Introduction
... Alternating Current (AC) amplifier Example: Microphone amplifier, signal is AC and is changing at a certain frequency range. Current is AC OpLoad alternating not stable. Source amp Use capacitors to connect different stages, so no need Each stage can have its owe to consider biasing problems. b ...
... Alternating Current (AC) amplifier Example: Microphone amplifier, signal is AC and is changing at a certain frequency range. Current is AC OpLoad alternating not stable. Source amp Use capacitors to connect different stages, so no need Each stage can have its owe to consider biasing problems. b ...
LTC3554/LTC3554-1/LTC3554-2/LTC3554-3
... The LTC®3554 family* are micropower, highly integrated power management and battery charger ICs for single-cell Li-Ion/Polymer battery applications. They include a PowerPath™ manager with automatic load prioritization, a battery charger, an ideal diode and numerous internal protection features. Desi ...
... The LTC®3554 family* are micropower, highly integrated power management and battery charger ICs for single-cell Li-Ion/Polymer battery applications. They include a PowerPath™ manager with automatic load prioritization, a battery charger, an ideal diode and numerous internal protection features. Desi ...
PAM2301 Description Pin Assignments
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
LTM2889 - Isolated CAN FD µModule Transceiver and Power
... single supply powers both sides of the interface through an integrated, isolated DC/DC converter. Separate versions are available for 3.3V and 5V power supplies. The dual voltage CAN transceiver and the adjustable regulator allow 3.3V or 5V isolated power with either the 3.3V or 5V version. ...
... single supply powers both sides of the interface through an integrated, isolated DC/DC converter. Separate versions are available for 3.3V and 5V power supplies. The dual voltage CAN transceiver and the adjustable regulator allow 3.3V or 5V isolated power with either the 3.3V or 5V version. ...
Reliability in motion
... • Also known as starting inrush, this is the amount of current the motor can be expected to draw under starting conditions when full voltage is applied. • Service Factor - Motor load and current rating when loaded to the service factor on the nameplate of the motor. Base is 1.0 but for example, many ...
... • Also known as starting inrush, this is the amount of current the motor can be expected to draw under starting conditions when full voltage is applied. • Service Factor - Motor load and current rating when loaded to the service factor on the nameplate of the motor. Base is 1.0 but for example, many ...
datasheet SGDH
... AC power input terminals for the control circuit. Ground terminal. Ground to a maximum of 100 Ω. (class 3) Up to 5 kW: Connect an external regenerative resistor if regenerative energy is high. From 5.5 kW to 55 kW: There is no internal regenerative resistor. Be sure to connect an external regenerati ...
... AC power input terminals for the control circuit. Ground terminal. Ground to a maximum of 100 Ω. (class 3) Up to 5 kW: Connect an external regenerative resistor if regenerative energy is high. From 5.5 kW to 55 kW: There is no internal regenerative resistor. Be sure to connect an external regenerati ...
Full Feaured N+1 and ORing Power Rail Controller (Rev. C)
... The following descriptions refer to the pinout and the functional block diagram. A, C: The A pin serves as the simulated diode anode and the C as the cathode. GATE is driven high when V(AC) exceeds 10 mV. Both devices provide a strong GATE pull-down when V(AC) is less than the programmable fast turn ...
... The following descriptions refer to the pinout and the functional block diagram. A, C: The A pin serves as the simulated diode anode and the C as the cathode. GATE is driven high when V(AC) exceeds 10 mV. Both devices provide a strong GATE pull-down when V(AC) is less than the programmable fast turn ...
1ch Small Package High Side Switch ICs Datasheet
... VIN terminal and VOUT terminal are connected to the drain and the source of switch MOSFET respectively. And the VIN terminal is used also as power source input to internal control circuit. When the switch is turned ON from EN,/EN control input, the switch is bidirectional. VIN terminal and VOUT term ...
... VIN terminal and VOUT terminal are connected to the drain and the source of switch MOSFET respectively. And the VIN terminal is used also as power source input to internal control circuit. When the switch is turned ON from EN,/EN control input, the switch is bidirectional. VIN terminal and VOUT term ...
Thesis
... turn-off process.By the nature of resonant tank and ZCS, the peak switch current is much higher than that in a square wave. In addition, a high voltage becomes established across the switch in the off- state after the resonant oscillation. When switch on the capacitor will be discharged ...
... turn-off process.By the nature of resonant tank and ZCS, the peak switch current is much higher than that in a square wave. In addition, a high voltage becomes established across the switch in the off- state after the resonant oscillation. When switch on the capacitor will be discharged ...
PDF
... capabilities of static switch devices such as IGBTs with voltage rating up to 4.5 kV commercially available, has made the use of the voltage source inverters (VSI) feasible for high-power applications. High power and high-voltage conversion systems have become very important issues for the power ele ...
... capabilities of static switch devices such as IGBTs with voltage rating up to 4.5 kV commercially available, has made the use of the voltage source inverters (VSI) feasible for high-power applications. High power and high-voltage conversion systems have become very important issues for the power ele ...
Complete PDF Edition (1,270 KB)
... Inverter technology and elevator group control using artificial intelligence are among the important innovations designed to improve convenience and comfort. Elevators are also being designed to add a visual accent to the buildings within which they are used. As we enter the 21st century, we can exp ...
... Inverter technology and elevator group control using artificial intelligence are among the important innovations designed to improve convenience and comfort. Elevators are also being designed to add a visual accent to the buildings within which they are used. As we enter the 21st century, we can exp ...
Buck converter class notes
... • The small capacitances of the MOSFET and diode, acting in parallel with each other as a net parasitic capacitance, interact with L to produce an oscillation • The output C is in series with the net parasitic capacitance, but C is so large that it can be ignored in the oscillation phenomenon ...
... • The small capacitances of the MOSFET and diode, acting in parallel with each other as a net parasitic capacitance, interact with L to produce an oscillation • The output C is in series with the net parasitic capacitance, but C is so large that it can be ignored in the oscillation phenomenon ...
technical report iec tr 60909-1
... (figure 9) in the case of over- or under-excited for the partial short-circuit current I kF2 operation before the short circuit ...........................................................................................59 Figure 14 – Cumulative frequency H of the deviations calculated with equation ...
... (figure 9) in the case of over- or under-excited for the partial short-circuit current I kF2 operation before the short circuit ...........................................................................................59 Figure 14 – Cumulative frequency H of the deviations calculated with equation ...
SPDT switch MMIC enables high - Defense Electronics Magazine
... Faced with the decision to either contract a trusted MMIC supplier disadvantage of PIN diodes is that they are current-controlled devices to customize a chip solution, or keep the MMIC design in-house, the and, therefore, require more complex driver circuitry than voltage- latter approach was chosen ...
... Faced with the decision to either contract a trusted MMIC supplier disadvantage of PIN diodes is that they are current-controlled devices to customize a chip solution, or keep the MMIC design in-house, the and, therefore, require more complex driver circuitry than voltage- latter approach was chosen ...
Endeavor Series
... CSI 263353.01ED – Static Uninterruptible Power Supply Systems Endeavor Series ...
... CSI 263353.01ED – Static Uninterruptible Power Supply Systems Endeavor Series ...
Power engineering
Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.