• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Calculating AC Line Voltage Drop for M250
Calculating AC Line Voltage Drop for M250

... out-of-range trip issues due to high line voltage conditions. Less resistance in conductors also results in less heat at the terminals, less power loss, and improved performance of the PV system. When designing circuits for electrical loads, these calculations are commonly called voltage drop (VDrop ...
WECC-0107 VAR-501-WECC-2 Power System Stabilizers Posting 4
WECC-0107 VAR-501-WECC-2 Power System Stabilizers Posting 4

... WECC currently does not have a RRS that specifies the threshold at which a PSS must be installed; however, WECC does have an existing policy that addresses that threshold. (Under WECC’s current policy, a PSS is not installed on a station service generator.) Under WECC’s current policy, a PSS is inst ...
LIMEL Integrated Laboratory for Electrical Machines Laboratory structure
LIMEL Integrated Laboratory for Electrical Machines Laboratory structure

... LIMEL, Electrical Machines Integrated Laboratory is a set of different elements that can be interconnected to form a complete learning and teaching center. From the minimum configuration to the most advanced one (always depending on the customer’s choice) EDIBON offers a means of learning electric f ...
Liebert RDC™ Remote Distribution Cabinet
Liebert RDC™ Remote Distribution Cabinet

™ ZXMS6005SG 60V N-CHANNEL SELF PROTECTED ENHANCEMENT MODE
™ ZXMS6005SG 60V N-CHANNEL SELF PROTECTED ENHANCEMENT MODE

... level input. It integrates over-temperature, over-current, over-voltage (active clamp) and ESD protected logic level functionality. The ZXMS6005SG is ideal as a general purpose switch driven from 3.3V or 5V microcontrollers in harsh environments where standard MOSFETs are not rugged enough. ...
NCP1653, NCP1653A Compact, Fixed−Frequency, Continuous
NCP1653, NCP1653A Compact, Fixed−Frequency, Continuous

... operation reduces the application di/dt and the resulting interference. The NCP1653 is designed in a compact 8−pin package which offers the minimum number of external components. It simplifies the design and reduces the cost. The output stage of the NCP1653 incorporates ±1.5 A current capability for ...
EE-339 - Analog Devices
EE-339 - Analog Devices

... not substantially increase the value of the needed Vcntrl signal. A Panasonic Schottky barrier diode MA27D29 has a Vdf of 0.25 V, which is low enough to be used in this application. For other diodes, the calculation of R1/R2 should be made after adding Vdf to Vcntrl(min). ...
LM2676 - Texas Instruments
LM2676 - Texas Instruments

... and load regulation characteristics. High efficiency (>90%) is obtained through the use of a low ONresistance DMOS power switch. The series consists of fixed output voltages of 3.3-V, 5-V, and 12-V and an adjustable output version. ...
AND8123 - Power Factor Correction Stages
AND8123 - Power Factor Correction Stages

CA235001EN
CA235001EN

... General information The necessity of providing surge arrester protection on low-voltage circuits is fundamentally the same as for primary system protection. While secondary lines usually are shorter than primary lines, they still are subject to surges which can cause stresses beyond the insulation w ...
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... High speed comparators in ultra-deep submicrometer (UDSM) CMOS technologies suffer from low supply voltages especially, when considering the fact that threshold voltages of the devices have not been scaled at the same pace as the supply voltages of the modern CMOS processes. The general trend in CMO ...
- Enphase Energy
- Enphase Energy

... Applying proper voltage rise calculations in your system design helps prevent nuisance voltage out-of-range trip issues due to high line voltage conditions. Less resistance in conductors also results in less power loss, less heat at the terminals, and improves performance of the PV system. When desi ...
Aalborg Universitet Modulation Schemes With Enhanced Switch Thermal Distribution for Single-Phase
Aalborg Universitet Modulation Schemes With Enhanced Switch Thermal Distribution for Single-Phase

... six-switch topology will hence be referred to as the H6 ac-dc-ac converter, which has also been tested as a UPS, a power conditioner and a power decoupling converter [20] [23] [25]. The B6 and H6 converters are thus structurally different, even though they use the same number of switches, and face t ...
NEMA # ICS-14 - Hubbell Industrial Controls
NEMA # ICS-14 - Hubbell Industrial Controls

... This Application Guide represents the result of many years of research, investigation, and experience by the members of the NEMA Industrial Control and Systems Subcommittee on Fire Pump Control. It was written as a service in response to the many questions from the user public, specifiers, and inspe ...
Model SMA8715 - Electro Mavin
Model SMA8715 - Electro Mavin

Lesson -13:
Lesson -13:

... from the bottom group (T2, T4, T6) must conduct. It can be argued as in the case of an uncontrolled converter only one device from these two groups will conduct. Then from symmetry consideration it can be argued that each thyristor conducts for 120° of the input cycle. Now the thyristors are fired i ...
Practical Power Solutions
Practical Power Solutions

... The ability of an electronic device to reject power supply ripple and noise is key to determining the ripple and noise allowable on its power inputs. Ripple and noise rejection ability is specified as the PSRR (Power Supply Rejection Ratio). We will use an op amp as an initial example. If the supply ...
product guide-2003 - Clarke Power Generation
product guide-2003 - Clarke Power Generation

Pulse Load Handling for Fixed Linear Resistors
Pulse Load Handling for Fixed Linear Resistors

... The capability of similar resistor styles to withstand single energy pulses is dependant on the resistive technology. For extreme pulse load conditions Vishay carbon film, metal glaze, and wirewound resistors are preferrable. With increasing duration times the maximum peak power becomes more and mor ...
S8VM (15/30/50/100/150/300/600/1,500
S8VM (15/30/50/100/150/300/600/1,500

... 2. Refer to Engineering Data (300-W, 600-W, 1,500-W Models) on page 17 to 19 for details. 3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +20% of the voltage adjustment range. If the adjuster is turned too far, it may activate the overvoltage protection f ...
36V H-Bridge Transformer Driver for Isolated Supplies General Description Benefits and Features
36V H-Bridge Transformer Driver for Isolated Supplies General Description Benefits and Features

... The MAX13256 H-bridge transformer driver provides a simple solution for making isolated power supplies up to 10W. The device drives a transformer’s primary coil with up to 300mA of current from a wide 8V to 36V DC supply. The transformer’s secondary-to-primary winding ratio defines the output voltag ...
DC TO AC POWER INVERTER
DC TO AC POWER INVERTER

Delphi D12S300-1 Non-Isolated Point of Load
Delphi D12S300-1 Non-Isolated Point of Load

... The ENABLE (on/off) input allows external circuitry to put the D12S300-1 converter into a low power dissipation (sleep) mode. Positive ENABLE is available as standard. Positive ENABLE units of the D12S300-1 series are turned on if the ENABLE pin is high or floating. Pulling the pin low will turn off ...
LM2747 - Texas Instruments
LM2747 - Texas Instruments

... The LM2747 is a voltage-mode, high-speed synchronous buck regulator with a PWM control scheme. It is designed for use in set-top boxes, thin clients, DSL/Cable modems, and other applications that require high efficiency buck converters. It has output shutdown (SD), input undervoltage lock-out (UVLO) ...
ISO Rules Part 500 Facilities Division 502 Technical Requirements
ISO Rules Part 500 Facilities Division 502 Technical Requirements

... (c) the root mean square phase-to-phase voltage value at the transmission system step-up transformer of the generating unit to be used as the one hundred percent (100%) voltage value; (d) the root mean square phase-to-phase voltage value at the stator winding terminals to be used as the one hundred ...
< 1 ... 135 136 137 138 139 140 141 142 143 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report