• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TPS75003 - Texas Instruments
TPS75003 - Texas Instruments

LM2747 - Texas Instruments
LM2747 - Texas Instruments

... The LM2747 is a voltage-mode, high-speed synchronous buck regulator with a PWM control scheme. It is designed for use in set-top boxes, thin clients, DSL/Cable modems, and other applications that require high efficiency buck converters. It has output shutdown (SD), input undervoltage lock-out (UVLO) ...
ISO Rules Part 500 Facilities Division 502 Technical Requirements
ISO Rules Part 500 Facilities Division 502 Technical Requirements

... (c) the root mean square phase-to-phase voltage value at the transmission system step-up transformer of the generating unit to be used as the one hundred percent (100%) voltage value; (d) the root mean square phase-to-phase voltage value at the stator winding terminals to be used as the one hundred ...
4 Transformers
4 Transformers

... The “ampere-turns” stay constant at N 1 I 1 = N 2 I 2 ; this fundamental relationship holds well for power and distribution transformers. A transformer has a magnetic core that can carry large magnetic fields. The cold-rolled, grain-oriented steels used in cores have permeabilities of over 1000 time ...
DESIGN AND FABRICATION OF SINGLE PHASE INDUCTION
DESIGN AND FABRICATION OF SINGLE PHASE INDUCTION

... A motor operates on the principle that a current- conductor placed in a magnetic field experiences a magnetic force whose direction is defined by the Fleming’s Left – hand Rule and whose magnitude is given by the expression , F=BIl Newton [1,2] Consider the DC motor shown below; for the DC motor sho ...
Hardware and Installation Manual
Hardware and Installation Manual

Microwave Oven Service Manual LD510D CAUTION
Microwave Oven Service Manual LD510D CAUTION

SM12 Features Mechanical Data
SM12 Features Mechanical Data

... indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more U ...
experimental characterization regarding two types of
experimental characterization regarding two types of

... I. INTRODUCTION Lighting systems have been experiencing a huge evolution, specifically in the past decades, underpinned by the use of power electronics in the process of driving newer light sources which aim energy efficiency. By the last and present decades, a new lighting concept has emerged: the ...
OIP A 67 dBm Multistacked Junction Varactor 3
OIP A 67 dBm Multistacked Junction Varactor 3

... low impedance path (relative to the AC impedance of the varactor capacitance itself) between the center node and two RF terminals ( and ) at low frequencies. At the same time, there must be a high impedance for the high frequency components (fundamental and higher harmonics) between the center node ...
Untitled
Untitled

... Electric power quality requirements are very high nowadays. This quality is assessed by means of many of parameters, including harmonic distortion, which means, that voltage or current waveform is not perfectly sinusoidal. Such distortion is caused by harmonic currents, generated by nonlinear loads. ...
REF3112 数据资料 dataSheet 下载
REF3112 数据资料 dataSheet 下载

AN60 - PCMCIA Card and Card Socket Power
AN60 - PCMCIA Card and Card Socket Power

... voltage switching requirements, there are many real world requirements that must also be considered. These issues include switch resistance, inrush current during voltage switching, voltage ringing during switching, short-circuit protection and cost effectiveness as a system, not just the function. ...
Performance comparison of Seven Level Inverter and Nine Level
Performance comparison of Seven Level Inverter and Nine Level

... purpose of integrating renewable energy to the grid is to provide active power by means of power electronic devices. The voltage change in multilevel inverter is used to improve the power conversion efficiency of inverter and also reduces the switching stress on the inverter [6]-[7]. An inverter and ...
BASIC SET-UP GUIDE — HAVOC SPORT ESC
BASIC SET-UP GUIDE — HAVOC SPORT ESC

... Li-Po batteries that cannot supply the amount of current required by this system, cross-connection of battery/ motor power wires, overheating solder tabs, reverse voltage application, damage resulting from thermal overload or short-circuiting motor (or connecting a brushless motor sensor harness whi ...
AC motor - induction2
AC motor - induction2

... Characteristics for NEMA designs…. All motors, except class D, operate at %5 slip or less at full load. • Class B (IEC Class N) motors are the default motor to use in most applications. With a starting torque of LRT = 150% to 170% of FLT, it can start most loads, without excessive starting current ( ...
VX / MX Dimmer Manual
VX / MX Dimmer Manual

... The VX dimmer system uses a modular control card for each 12 channel dimmer. This control card incorporates over voltage detection and shutdown to protect the dimmer electronics and lamp loads from destruction. The VX control card features three green LED's for power indication. These indicators sh ...
Data Book 1 - Talking Electronics
Data Book 1 - Talking Electronics

... to identify each lead on the actual component. The symbol does not identify the actual pins on the device. It only shows the component in the circuit and how it is wired to the other components, such as input line, output, drive lines etc. You cannot relate the shape or size of the symbol with the c ...
Circuit Breaker Types.doc
Circuit Breaker Types.doc

... Large low-voltage molded case and power circuit breakers may have electrical motor operators, allowing them to be tripped (opened) and closed under remote control. These may form part of an automatic transfer switch system for standby power. Low-voltage circuit breakers are also made for direct-curr ...
LT3800 - Linear Technology
LT3800 - Linear Technology

... The LT3800 is biased using a local linear regulator to generate internal operational voltages from the VIN pin. Virtually all of the circuitry in the LT3800 is biased via an internal linear regulator output (VCC). This pin is decoupled with a low ESR 1μF capacitor to PGND. The VCC regulator generate ...
CY7C65100 Four-port Universal Serial Bus Fixed
CY7C65100 Four-port Universal Serial Bus Fixed

... The CY7C65100 series offers high-performance fixed-function Universal Serial Bus (USB) hub devices that comply with USB Specification, Rev. 1.1. Up to four downstream USB ports are available to expand the USB attachment points available in your PC system. These self-contained devices require no firm ...
MAX16914/MAX16915 Ideal Diode, Reverse-Battery, and Overvoltage Protection Switch/Limiter Controllers with External MOSFETs
MAX16914/MAX16915 Ideal Diode, Reverse-Battery, and Overvoltage Protection Switch/Limiter Controllers with External MOSFETs

... MAX16914/MAX16915 Ideal Diode, Reverse-Battery, and Overvoltage Protection Switch/Limiter Controllers with External MOSFETs General Description The MAX16914/MAX16915 low-quiescent-current overvoltage and reverse-battery protection controllers are designed for automotive and industrial systems that m ...
Starting Time Calculation for Induction Motor
Starting Time Calculation for Induction Motor

... the heavy applications requirement. Some are considered large even in comparison to the total capacity of large industrial power systems. Starting of such large motors can cause adverse effects to any locally connected load, other motors and also to buses, which are electrically remote from the poin ...
Overload Relays
Overload Relays

... Most motor applications require the use of remote control devices to start and stop the motor. Magnetic contactors (similar to the ones shown below) are commonly used to provide this function. Contactors are also used to control distribution of power in lighting and heating circuits. ...
10. Full 2911k
10. Full 2911k

< 1 ... 136 137 138 139 140 141 142 143 144 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report