• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Generator Protection Overcomes Current Transformer Limitations
Generator Protection Overcomes Current Transformer Limitations

... CTs forming the differential zone will saturate similarly, thereby minimizing the possibility of a spurious differential current. Note that matching the C class does not guarantee that the CT excitation characteristics will be the same. The size of the switchgear limits the dimensions of the CT and ...
HV-Maxx Instructions.pm
HV-Maxx Instructions.pm

MAX8895 Evaluation Kit Evaluates:  MAX8895W/MAX8895X/MAX8895Y General Description Features
MAX8895 Evaluation Kit Evaluates: MAX8895W/MAX8895X/MAX8895Y General Description Features

... Detailed Description of Hardware The MAX8895 EV kit evaluates the MAX8895_ integrated single-cell Li+ chargers with USB enumeration capability. The EV kit negotiates charging current from the USB host or hub, without processor intervention. The MAX8895_ also automatically detects for a dedicated cha ...
T.C. Neugebauer and D.J. Perreault, “Computer-Aided Optimization of DC/DC Converters for Automotive Applications,” IEEE Transactions on Power Electronics , Vol. 18, No. 3, May 2003, pp. 775-783.
T.C. Neugebauer and D.J. Perreault, “Computer-Aided Optimization of DC/DC Converters for Automotive Applications,” IEEE Transactions on Power Electronics , Vol. 18, No. 3, May 2003, pp. 775-783.

... loop randomly chooses the design variables that are needed to construct the power stage of the converter. The power stage design algorithm then uses these values as initial conditions and determines essential values of the design, chooses components to ensure proper operation of the converter, and m ...
Simple Electric Circuits
Simple Electric Circuits

... In the box below draw the symbol for each of the components Component ...
ADP1828 数据手册DataSheet 下载
ADP1828 数据手册DataSheet 下载

... Frequency Control Input. Low for 300 kHz, high for 600 kHz, or connect a resistor from FREQ to GND to set the freerunning frequency between 300 kHz and 600 kHz. Frequency Synchronization Input. Accepts external signals between 300 kHz and 600 kHz if FREQ is set to low, or between 600 kHz and 1.2 MHz ...
XR Series IV User Manual Programmable DC Power Supply
XR Series IV User Manual Programmable DC Power Supply

III Sem
III Sem

BC857BLP Features Mechanical Data
BC857BLP Features Mechanical Data

... hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by on ...
Basic Precipitator Troubleshooting
Basic Precipitator Troubleshooting

... Under Voltage Trip ...
High Speed Layout Design Guidelines This application note
High Speed Layout Design Guidelines This application note

... technique will couple the transmission line tightly to the ground plane and help decouple it from adjacent signals. • Use differential routing techniques where possible, especially for critical nets (i.e., match the lengths as well as the gyrations that each trace goes through). • If there is signif ...
AI34212218
AI34212218

... inverter is shown in Fig. 4 (a). From Eq. (1), the CMV is one third of the summation of the instantaneous voltages in a three phase system. From Eq. (1), the CMV is one third of the summation of the instantaneous voltages in a three phase system. A N-level inverter produces a N-level output voltage ...
FM3 Microcontroller Low Voltage Detect Interrupt Circuit Setting/Usage
FM3 Microcontroller Low Voltage Detect Interrupt Circuit Setting/Usage

KSH200 NPN Epitaxial Silicon Transistor KSH200 — NPN
KSH200 NPN Epitaxial Silicon Transistor KSH200 — NPN

... Fairchild and our Authorized Distributors will stand behind all warranties and will appropriately address any warranty issues that may arise. Fairchild will not provide any warranty coverage or other assistance for parts bought from Unauthorized Sources. Fairchild is committed to combat this global ...
ASCO Medium Voltage Automatic Transfer Switches (MV-ATS)
ASCO Medium Voltage Automatic Transfer Switches (MV-ATS)

... [3000] amps and a maximum symmetrical interrupting rating* of [40kA/250mVA - 4.76 kV system] [50kA/350MVA - 4.76 kV system] [25kA/500MVA - 15 kV system] [40kA/750MVA - 15 kV system] [50kA/1000MVA - 15 kV system]. Furnish vacuum circuit breakers with one vacuum interrupter per phase. Breakers of sam ...
XLS Series Reference Manual
XLS Series Reference Manual

... extremely high power levels. They must be treated with respect and correctly installed if they are to provide the many years of reliable service for which they were designed. In addition, XLS Series amplifiers include a number of features which require some explanation before they can be used to the ...
installation and maintenance manual
installation and maintenance manual

DIGIPLAN 1054 STEPPER MOTOR DRIVE INSTRUCTION
DIGIPLAN 1054 STEPPER MOTOR DRIVE INSTRUCTION

... At this point it is appropriate to define some of the terms used in connection with stepper motors and their operation. Some of the terms have been used already and others will be introduced in the next section. The list has been confined to those terms which are necessary for a basic understanding ...
CW4301569573
CW4301569573

... is at a greater potential than the Vn, the reference voltage, then the output of the comparator is a logic 1, where as if the Vp is at a potential less than the Vn , the output of the comparator is at logic 0. If Vp > Vn, then Vo= logic 1. If Vp < Vn, then Vo= logic 0. In UDSM (Ultradeep Submicromet ...
FAN21SV04 — TinyBuck™ 4 A, 24 V Single-Input Features
FAN21SV04 — TinyBuck™ 4 A, 24 V Single-Input Features

... one package, which enables designers to solve highcurrent requirements in a small area with minimal external components, thereby reducing cost. Onboard internal 5 V regulator enables single-supply operation for input voltages >6.5 V. The FAN21SV04 can be configured to drive multiple slave devices OR ...
SP232E 数据资料DataSheet下载
SP232E 数据资料DataSheet下载

ASCO Medium Voltage Automatic Delayed Transition Transfer
ASCO Medium Voltage Automatic Delayed Transition Transfer

... [3000] amps and a maximum symmetrical interrupting rating* of [40kA/250mVA - 4.76 kV system] [50kA/350MVA - 4.76 kV system] [25kA/500MVA - 15 kV system] [40kA/750MVA - 15 kV system] [50kA/1000MVA - 15 kV system]. Furnish vacuum circuit breakers with one vacuum interrupter per phase. Breakers of same ...
SSM2517 数据手册DataSheet 下载
SSM2517 数据手册DataSheet 下载

... The SSM2517 features a high efficiency, low noise modulation scheme that requires no external LC output filters. The closed-loop, three-level modulator design retains the benefits of an all-digital amplifier, yet enables very good PSRR and audio performance. The modulation continues to provide high ...
BD8132FV
BD8132FV

... The OSC generates the frequency that determines the Amp's refresh time. External input can be selected using serial input. (For the BD8139AEFV, external input is selected using the external pin.) ・Power On Reset When the digital power supply DVCC is activated, each IC generates a reset signal to ini ...
Less energy. Enhanced performances.
Less energy. Enhanced performances.

< 1 ... 111 112 113 114 115 116 117 118 119 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report