![SURGE PROTECTIVE DEVICES](http://s1.studyres.com/store/data/013078132_1-a04df1bda59754e99b60e22380b02071-300x300.png)
SURGE PROTECTIVE DEVICES
... SPDs shall be installed near the origin of the installation or in the main switchboard assembly, however additional SPDs might be necessary to protect sensitive equipment and when the distance from the main SPD to the next distribution board is big (> 30m). These secondary SPDs shall be coordinated ...
... SPDs shall be installed near the origin of the installation or in the main switchboard assembly, however additional SPDs might be necessary to protect sensitive equipment and when the distance from the main SPD to the next distribution board is big (> 30m). These secondary SPDs shall be coordinated ...
Voltage-Controlled Oscillator at 6 GHz for Doppler Radar in Heart
... noise is described in terms of the power level in a 1 Hz band at some frequency offset from the carrier, in dBc/Hz at х Hz from the carrier, where х could have values from 100 Hz to 10 MHz, depending on application. Unlike an ideal signal whose phase and amplitude are constant in time, the real sign ...
... noise is described in terms of the power level in a 1 Hz band at some frequency offset from the carrier, in dBc/Hz at х Hz from the carrier, where х could have values from 100 Hz to 10 MHz, depending on application. Unlike an ideal signal whose phase and amplitude are constant in time, the real sign ...
DM-100 • DM-110
... AC measurements are usually displayed as RMS (root-mean-square) values. Two AC measurement methods are average-responding RMS calibrated and true RMS-reading. The average-responding RMS calibrated method takes the average value of the input signal, multiplies it by 1.11, and displays the result. Thi ...
... AC measurements are usually displayed as RMS (root-mean-square) values. Two AC measurement methods are average-responding RMS calibrated and true RMS-reading. The average-responding RMS calibrated method takes the average value of the input signal, multiplies it by 1.11, and displays the result. Thi ...
DMS-EB - Murata Power Solutions
... digit meters operating in the single-ended mode (SG5 closed) using the meter's internal reference (SG13 closed). This configuration is the most common and works well for most simple voltage measurements. Many of the applications described below apply to both DMS-30 and DMS-40 meters. However, Applica ...
... digit meters operating in the single-ended mode (SG5 closed) using the meter's internal reference (SG13 closed). This configuration is the most common and works well for most simple voltage measurements. Many of the applications described below apply to both DMS-30 and DMS-40 meters. However, Applica ...
Enhancing Data Integrity and Reliability of Smart
... Smart Metering Solutions with CMOS Digital Isolators The automated meter reading (AMR) market is projected to grow by double digits over the next several years as consumers upgrade from traditional electromechanical meters to grid-connected smart meters. Today’s sophisticated smart meters use the la ...
... Smart Metering Solutions with CMOS Digital Isolators The automated meter reading (AMR) market is projected to grow by double digits over the next several years as consumers upgrade from traditional electromechanical meters to grid-connected smart meters. Today’s sophisticated smart meters use the la ...
投影片 1
... amplifier to achieve broadband and low noise. 3. The common source single-stage amplifier is cascaded to the conventional distributed amplifier to improve the gain at high frequency. 4. The measured a.gain of the integrated LNA is 10dB b.3dB bandwidth from 2.7 to 9.1 GHz c. average noise figure is 4 ...
... amplifier to achieve broadband and low noise. 3. The common source single-stage amplifier is cascaded to the conventional distributed amplifier to improve the gain at high frequency. 4. The measured a.gain of the integrated LNA is 10dB b.3dB bandwidth from 2.7 to 9.1 GHz c. average noise figure is 4 ...
Nanoradian sensitivity Kerr effect apparatus
... sources of spurious signals: (1) electrical pick up, (2) occultation effects, and (3) window Kerr and stress birefringence effects. Electrical pick up is eliminated by breaking ground loops associated with the ac high voltage (radiative coupling is insignificant at 2 kHz). Floating the power amplifi ...
... sources of spurious signals: (1) electrical pick up, (2) occultation effects, and (3) window Kerr and stress birefringence effects. Electrical pick up is eliminated by breaking ground loops associated with the ac high voltage (radiative coupling is insignificant at 2 kHz). Floating the power amplifi ...
The Physics of Noise
... Noise often refers to random noise, which can be fundamental (ie, Johnson noise) or instrumental (such as amplifier noise) Shot noise from statistical fluctuations — the same as counting noise Interference usually means some other signal “getting into” your measurement, synonymous with “pick-up” Osc ...
... Noise often refers to random noise, which can be fundamental (ie, Johnson noise) or instrumental (such as amplifier noise) Shot noise from statistical fluctuations — the same as counting noise Interference usually means some other signal “getting into” your measurement, synonymous with “pick-up” Osc ...
Sensors
... • The second method of voice output involves having a human speak the words into a microphone. • A computer stores each word digitally, and this digital information is then converted back into analog speech one word at a time, as the computer or robot speaks. • This method tend to sound very much li ...
... • The second method of voice output involves having a human speak the words into a microphone. • A computer stores each word digitally, and this digital information is then converted back into analog speech one word at a time, as the computer or robot speaks. • This method tend to sound very much li ...
Testing and Electrical Safety Physical Measurements
... • Measurement of sound intensity in any acoustic environment: noisy or quiet, high-pitched, low-pitched or wide-band, intermittent or continuous • Complies with the IEC 651 standard • A and C frequency weighting ...
... • Measurement of sound intensity in any acoustic environment: noisy or quiet, high-pitched, low-pitched or wide-band, intermittent or continuous • Complies with the IEC 651 standard • A and C frequency weighting ...
Chapter 1 Problems
... A square wave of the type shown in Figure 1-lc has a peakto-peak amplitude of 10V and a frequency of 200Hz. The term representing the fifth harmonic is approximately: a. 1.27 sin 6283t b. 0.2 sin 6283t c. 4 sin 3142t d. 6.35 sin 6283t ...
... A square wave of the type shown in Figure 1-lc has a peakto-peak amplitude of 10V and a frequency of 200Hz. The term representing the fifth harmonic is approximately: a. 1.27 sin 6283t b. 0.2 sin 6283t c. 4 sin 3142t d. 6.35 sin 6283t ...
Changes to EN61000-3-2
... • The current distortion leads to to the phenomenon of triplen harmonic currents flowing in the neutral of three-phase systems – a fire risk in large office installations. • and to voltage distortion that can cause overheating in ...
... • The current distortion leads to to the phenomenon of triplen harmonic currents flowing in the neutral of three-phase systems – a fire risk in large office installations. • and to voltage distortion that can cause overheating in ...
NFPA 70E and Electrical Testing Safety
... activities. It is intended to be followed by employers, employees, engineers, electricians, their supervisors, and new hires such as apprentices. OSHA (Occupational Safety & Health Administration) bases its electrical safety mandates on the NFPA 70E standard. It provides guidance on employee trainin ...
... activities. It is intended to be followed by employers, employees, engineers, electricians, their supervisors, and new hires such as apprentices. OSHA (Occupational Safety & Health Administration) bases its electrical safety mandates on the NFPA 70E standard. It provides guidance on employee trainin ...
Model MA260
... Use caution with voltages above 30VACrms, 42VAC peak, or 60VDC. These voltages pose a shock hazard. Probe assemblies to be used for MAINS measurements must be rated as appropriate for measurement Category III or IV according to IEC 61010‐031 and must have a voltage rating of at least the voltage o ...
... Use caution with voltages above 30VACrms, 42VAC peak, or 60VDC. These voltages pose a shock hazard. Probe assemblies to be used for MAINS measurements must be rated as appropriate for measurement Category III or IV according to IEC 61010‐031 and must have a voltage rating of at least the voltage o ...
63-1337—02 - Class 200 Meters Three-Phase Meters
... damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’ fees, arising out of, or resulting from, any modification to the literature by you. ...
... damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’ fees, arising out of, or resulting from, any modification to the literature by you. ...
Three Stage Low Noise Operational Amplifier Design for a 0.18 um
... Fig. 4(a) shows the schematic of a three stage low noise, high-gain operational amplifier based on the single stage described above. When three or more voltage-gain stages must be cascaded to achieve the desired gain, the op amp will have three or more poles, and frequency compensation becomes compl ...
... Fig. 4(a) shows the schematic of a three stage low noise, high-gain operational amplifier based on the single stage described above. When three or more voltage-gain stages must be cascaded to achieve the desired gain, the op amp will have three or more poles, and frequency compensation becomes compl ...
Selection Guide: Thermometry Bridges and Precision Thermometers
... take ratio readings. In a secondary calibration laboratory for best practise a thermometer being calibrated is compared directly to a calibrated Standard Platinum Resistance Thermometer. In a primary laboratory the SPRT is compared to a temperature controlled Standard Resistor. Different vendors of ...
... take ratio readings. In a secondary calibration laboratory for best practise a thermometer being calibrated is compared directly to a calibrated Standard Platinum Resistance Thermometer. In a primary laboratory the SPRT is compared to a temperature controlled Standard Resistor. Different vendors of ...
Chapter 4: DC Meters - Part 1
... Current from a circuit in which measurements are being made with the meter passes through the windings of the moving coil. Current through the coil causes it to behave as an electromagnet with its own north and south poles. The poles of the electromagnet interact with the poles of the permanent mag ...
... Current from a circuit in which measurements are being made with the meter passes through the windings of the moving coil. Current through the coil causes it to behave as an electromagnet with its own north and south poles. The poles of the electromagnet interact with the poles of the permanent mag ...
Data Sheet 85001-0556 -- Genesis Ceiling
... 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates tha ...
... 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates tha ...
Data Sheet S85001-0628 -- Genesis Outdoor
... Visible appliance synchronization is required to avoid causing issues with people who have Photosensitive Epilepsy (PSE). Notification appliance synchronization is also generally required when more than two strobe appliances are in the same field of view from any one location. All Genesis strobes me ...
... Visible appliance synchronization is required to avoid causing issues with people who have Photosensitive Epilepsy (PSE). Notification appliance synchronization is also generally required when more than two strobe appliances are in the same field of view from any one location. All Genesis strobes me ...
Lecture 3: Signal and Noise
... The performance of an amplifier can be discussed in terms of the additional noise at the output compared to the noise present at the input. NF = 10 log10(Pnoise-out/Pnoise-in) NF = 10 log10{(〈V2noise〉 + 〈V2amp〉)/〈V2noise〉} NF = 10 log10{1 + 〈V2amp〉)/〈V2noise〉} Here Vnoise is the noise present in the ...
... The performance of an amplifier can be discussed in terms of the additional noise at the output compared to the noise present at the input. NF = 10 log10(Pnoise-out/Pnoise-in) NF = 10 log10{(〈V2noise〉 + 〈V2amp〉)/〈V2noise〉} NF = 10 log10{1 + 〈V2amp〉)/〈V2noise〉} Here Vnoise is the noise present in the ...
Sound level meter
![](https://en.wikipedia.org/wiki/Special:FilePath/Optimus_Sound_Level_Meter.jpg?width=300)
A sound level meter or sound meter is an instrument that measures sound pressure level, commonly used in noise pollution studies for the quantification of different kinds of noise, especially for industrial, environmental and aircraft noise. However, the reading from a sound level meter does not correlate well to human-perceived loudness, which is better measured by a loudness meter. The current international standard that specifies sound level meter functionality and performance is the IEC 61672-1:2013.