• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Operating FAC-010-AB1-2.1 Alberta Reliability Standard
Operating FAC-010-AB1-2.1 Alberta Reliability Standard

... The following measures correspond to the requirements identified in Section 3 of this reliability standard. For example, MR1 is the measure for R1. MR1 Evidence of having a documented system operating limit methodology as required in requirement R1 exists. MR2 Evidence of the system operating limit ...
Aviation + Military EMC Testing Services
Aviation + Military EMC Testing Services

... To find out more: www.elitetest.com | 1-800-354-8311 ...
Wavenology EM Tutorial (Graphic Circuit Editor)
Wavenology EM Tutorial (Graphic Circuit Editor)

... 6. V probe with three resistors: graphic_circuit_demo\vProbe\vp01.wnt 7. Differential V probe with three resistors: graphic_circuit_demo\vProbe\vp02.wnt 8. I probe with three resistors: graphic_circuit_demo\IProbe\ip01.wnt 9. I probe with resistor, source and inductor: graphic_circuit_demo\IProbe\ip ...
Evaluating the Potential of an Energy Reduction Technique Based
Evaluating the Potential of an Energy Reduction Technique Based

... path, since it is expected that a typical circuit delay is shorter than the critical delay and that timing faults rarely occur[7]. For example, it has been reported that nearly 80% of paths have delays of half the critical time[21]. On the other hand, since the checker parts are used for detecting t ...
Data Bulletin Shedding Non-Priority Loads with
Data Bulletin Shedding Non-Priority Loads with

... The reflex load-shedding order is generated locally by the PowerPact H-, J-, or L-frame circuit breaker itself using the Micrologic electronic trip unit. The Micrologic E electronic trip unit (energy measurement) is used to manage alarms based on the monitoring of electrical variables such as the in ...
seminar - Voltimum
seminar - Voltimum

Wide VIN power management ICs simplify White
Wide VIN power management ICs simplify White

... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
Electric Linear Actuators, Hydraulic Systems
Electric Linear Actuators, Hydraulic Systems

... The load that must be moved in an application is a key factor in determining the most appropriate motion solution. As mentioned, load is one central specification that immediately disqualifies certain solutions. The units of measure for load — defined here as the force interacting with the motion de ...
. .OR How To Protect your 3-Phase Equipment Investment
. .OR How To Protect your 3-Phase Equipment Investment

... The table above shows voltage readings taken at the motor terminals on three different size induction motors and one synchronous type motor. The readings shown are with phase 3 disconnected. They show the effect of the voltage being generated by the open motor winding under different load conditions ...
DM74LS47 BCD to 7-Segment Decoder/Driver with Open
DM74LS47 BCD to 7-Segment Decoder/Driver with Open

... HIGH level and the ripple-blanking output (RBO) goes to a LOW level (response condition). Note 5: When the blanking input/ripple-blanking output (BI/RBO) is OPEN or held at a HIGH level, and a LOW level is applied to lamp test input, all segment outputs go to a LOW level. ...
safeguard [b-IEC 62368-1]
safeguard [b-IEC 62368-1]

self assessment
self assessment

1100_T2_13-4_lab2_electronicsI_manual
1100_T2_13-4_lab2_electronicsI_manual

... 3. how to use a breadboard to construct circuits. Recording data properly from a laboratory experiment is part of the learning process in this course. As such, you are required to complete a document called a lab sheet. We will provide Lab Sheet templates for Electronics Basics I & II (in eLearning ...
DM-100 • DM-110
DM-100 • DM-110

... • Do not expose this unit to rain or moisture. • Do not use the unit if it is wet or damaged. • Use test leads or accessories that are appropriate for the application. See the category and voltage rating of the test lead or accessory. • Inspect the test leads or accessory before use. They must be cl ...


Problem Solving Methods and Computer
Problem Solving Methods and Computer

Low Power Consumption Digital Signal Processor: Hi-Perion
Low Power Consumption Digital Signal Processor: Hi-Perion

Dec99Overheads - Western Regional Gas Conference
Dec99Overheads - Western Regional Gas Conference

Aalborg Universitet Applications
Aalborg Universitet Applications

... backup (reserve) protection that acts if the first one fails to clear the fault [2]. The maritime applications are no exception from this rule, as the requirements are even more stringent in this sector. The back-up protection is implemented in such way that whatever caused malfunction of the primar ...
Presentations 2 &3 : MICRO 2003 Review, by Theo Theocharides
Presentations 2 &3 : MICRO 2003 Review, by Theo Theocharides

...  Returning to full speed however, will likely reduce power savings if there are multiple misses and insufficient independent computations to overlap with the misses ...
issue - IET Electrical
issue - IET Electrical

... IEE Wiring Matters is a quarterly publication from the Institution of Engineering and Technology (IET). The IET is not as a body responsible for the opinions expressed. ©2007: The Institution of Engineering and Technology. All rights reserved. No part of this publication may be reproduced, stored in ...
Configuring a DC Operating Point Analysis in Multisim
Configuring a DC Operating Point Analysis in Multisim

No Slide Title
No Slide Title

... level (part, board, assembly, or the entire system). The following failure rate prediction methods are ...
datasheet - KANSAI
datasheet - KANSAI

... HIGH level and the ripple-blanking output (RBO) goes to a LOW level (response condition). Note 5: When the blanking input/ripple-blanking output (BI/RBO) is OPEN or held at a HIGH level, and a LOW level is applied to lamp test input, all segment outputs go to a LOW level. ...
MAXFILTERBRD Evaluates:  MAX7408–MAX7415/ MAX7418–MAX7425 General Description
MAXFILTERBRD Evaluates: MAX7408–MAX7415/ MAX7418–MAX7425 General Description

... An external clock that matches the specification of the corresponding IC data sheet can be used by cutting the trace of jumper JU2. Drive the CLK pin with a CMOS gate powered from 0 to VDD. Apply the clock signal to the CLK pad. ...
< 1 ... 123 124 125 126 127 128 129 130 131 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report