Electric Power
... For the passive designs that are exempted from providing the two offsite power sources required by GDC 17, the applicant should provide information on the single designated offsite power circuit provided from the transmission network with sufficient capacity and capability to power safety systems u ...
... For the passive designs that are exempted from providing the two offsite power sources required by GDC 17, the applicant should provide information on the single designated offsite power circuit provided from the transmission network with sufficient capacity and capability to power safety systems u ...
IOM MICRONEX (V2.2)
... correct new and replacement lamp in order to preserve the certification conditions and obtain the designed photometric performance. The lamp type is shown on the rating plate. Lamps should be replaced shortly after they do not light. One indication of the end of life for HPS lamps is 'cycling', wher ...
... correct new and replacement lamp in order to preserve the certification conditions and obtain the designed photometric performance. The lamp type is shown on the rating plate. Lamps should be replaced shortly after they do not light. One indication of the end of life for HPS lamps is 'cycling', wher ...
protective device for pumps / motors
... A relay combining both current sensing and voltage sensing operating principle can satisfactorily cover the basic protection requirements, by doing away with limitations. Microprocessor based protection relays may have such better protection level compared to solid state relays. This is because of f ...
... A relay combining both current sensing and voltage sensing operating principle can satisfactorily cover the basic protection requirements, by doing away with limitations. Microprocessor based protection relays may have such better protection level compared to solid state relays. This is because of f ...
MPS A 0 5
... DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when p ...
... DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when p ...
Tender text
... Including pictogram set acc. to ISO 7010 (arrow down, left, right, blind) with snap-in mounting. High service life via optimised LED operating conditions. Increased safety via redundant construction of LED unit consisting of 3-chip LEDs with high luminous efficacy >100 lm/W for significantly reduced ...
... Including pictogram set acc. to ISO 7010 (arrow down, left, right, blind) with snap-in mounting. High service life via optimised LED operating conditions. Increased safety via redundant construction of LED unit consisting of 3-chip LEDs with high luminous efficacy >100 lm/W for significantly reduced ...
OPERATOR MANUAL OSD461/OSD463 FM VIDEO FIBER OPTIC
... INTRODUCTION .................................................................................................................... 7 ...
... INTRODUCTION .................................................................................................................... 7 ...
Earth Fault Detection Basics in Theory
... resistor RE. During this, only the star point of the generator that was initially connected will be earthed via the neutral earthing resistor RE. In case that the generator circuit breaker of the generator whose star point was connected with, the neutral earthing resistor is switched off by the corr ...
... resistor RE. During this, only the star point of the generator that was initially connected will be earthed via the neutral earthing resistor RE. In case that the generator circuit breaker of the generator whose star point was connected with, the neutral earthing resistor is switched off by the corr ...
The Use And Misuse Of Circuit Protection Devices
... load rises above a certain point, it opens the line carrying that current. A circuit breaker is like a resettable fuse. Typically, it takes a defect in the circuit being protected to “blow” (open) a fuse. But if the fuse opens fast enough, it should help protect parts of the circuit that are not def ...
... load rises above a certain point, it opens the line carrying that current. A circuit breaker is like a resettable fuse. Typically, it takes a defect in the circuit being protected to “blow” (open) a fuse. But if the fuse opens fast enough, it should help protect parts of the circuit that are not def ...
M-ECho: A Middleware for Morphable Data-Streaming in Pervasive Systems
... and StrongARM CPU based iPAQs to mimic the computing system of a robot. Power measurements are obtained by monitoring current with a measurement circuit based upon a current sensor IC, and simultaneously measuring voltage. These values are measured with the Picoscope 212/50 PC-oscilloscope [2]. In t ...
... and StrongARM CPU based iPAQs to mimic the computing system of a robot. Power measurements are obtained by monitoring current with a measurement circuit based upon a current sensor IC, and simultaneously measuring voltage. These values are measured with the Picoscope 212/50 PC-oscilloscope [2]. In t ...
Electrical power conversion solutions for demanding rail
... percentage of its installation life for which it is ‘healthy’ and able to perform its required functions. Plus, availability depends not only on reliability and therefore mean time between failures (MTBF) but also on the time taken to effect a repair (mean time to repair or MTTR) if a fault does occ ...
... percentage of its installation life for which it is ‘healthy’ and able to perform its required functions. Plus, availability depends not only on reliability and therefore mean time between failures (MTBF) but also on the time taken to effect a repair (mean time to repair or MTTR) if a fault does occ ...
Turkey Point Units 6 & 7 COL Application Part 2 — FSAR
... Replace the existing information in DCD Subsection 8.1.1 with the following: FPL owns and operates the power transmission system for Turkey Point Units 6 & 7. FPL is the largest investor-owned electric utility in Florida, serving more than 4.4 million customers. The FPL power transmission system con ...
... Replace the existing information in DCD Subsection 8.1.1 with the following: FPL owns and operates the power transmission system for Turkey Point Units 6 & 7. FPL is the largest investor-owned electric utility in Florida, serving more than 4.4 million customers. The FPL power transmission system con ...
analog multimeter
... Measuring Current (cont’d.) • Caution: – Always turn off power before connecting an ammeter to a circuit – An analog ammeter must never be connected in parallel with any ckt component (s/c; fuse will blow & damage to meter) – Never connect an ammeter directly to a voltage source (s/c) • Internal re ...
... Measuring Current (cont’d.) • Caution: – Always turn off power before connecting an ammeter to a circuit – An analog ammeter must never be connected in parallel with any ckt component (s/c; fuse will blow & damage to meter) – Never connect an ammeter directly to a voltage source (s/c) • Internal re ...
06 System Grounding
... This system grounding arrangement is at the other end of the spectrum from solidly-grounded systems. An ungrounded system is a system where there is no intentional connection of the system to ground. The term “ungrounded system” is actually a misnomer, since every system is grounded through its inhe ...
... This system grounding arrangement is at the other end of the spectrum from solidly-grounded systems. An ungrounded system is a system where there is no intentional connection of the system to ground. The term “ungrounded system” is actually a misnomer, since every system is grounded through its inhe ...
Nexxus II LED - Bulkhead Luminaires
... aluminium enclosure with a toughened glass lens. The control gear is electronic with regulated lamp output. The LEDs work equally well at very low temperatures as they do at high and produce a product with very low overall power consumption. The LEDs also emit no ultra-violet light and no forward he ...
... aluminium enclosure with a toughened glass lens. The control gear is electronic with regulated lamp output. The LEDs work equally well at very low temperatures as they do at high and produce a product with very low overall power consumption. The LEDs also emit no ultra-violet light and no forward he ...
Risk Assessment
... switched on to continue Atlas operation and avoid Inner Detector degradation. All compressor station system elements should be kept in good condition as the back-up solution in serious Thermosiphon damage. ...
... switched on to continue Atlas operation and avoid Inner Detector degradation. All compressor station system elements should be kept in good condition as the back-up solution in serious Thermosiphon damage. ...
Alberta Reliability standard Transmission Relay Loadability PRC-023-AB-2
... September 6, 2012 1. Purpose The purpose of this reliability standard is to ensure the protective relay settings do not limit transmission loadability, do not interfere with an operator’s ability to take remedial action to protect the reliability of the system, and are set to reliably detect all fau ...
... September 6, 2012 1. Purpose The purpose of this reliability standard is to ensure the protective relay settings do not limit transmission loadability, do not interfere with an operator’s ability to take remedial action to protect the reliability of the system, and are set to reliably detect all fau ...
8 Hints for Debugging and Validating High-Speed Buses
... limits? The solution is a combination of test cards and software running on the SUT. A test card is a device that is used specifically for testing. It is designed for a specific slot-based or cable-based I/O system—PCI, PCI-X, or others—and operates like any other device designed for ...
... limits? The solution is a combination of test cards and software running on the SUT. A test card is a device that is used specifically for testing. It is designed for a specific slot-based or cable-based I/O system—PCI, PCI-X, or others—and operates like any other device designed for ...
STP 3 & 4 8.2 Offsite Power Systems
... The 345 kV transmission circuits are routed on rights-of-way as described above except for the distance from the rights-of-way to the STP 3 & 4 switchyard on the STPEGS plant property. In this small section, the 345 kV structures are arranged as depicted in Figure 8.2-2. The location of transmission ...
... The 345 kV transmission circuits are routed on rights-of-way as described above except for the distance from the rights-of-way to the STP 3 & 4 switchyard on the STPEGS plant property. In this small section, the 345 kV structures are arranged as depicted in Figure 8.2-2. The location of transmission ...
Fault tolerance
Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.