• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
OFSTP-27
OFSTP-27

... ramping may be observed. If such a problem has not shown a general trend of increase in magnitude with the number of test cycles, and if it has been demonstrated that the problem does not recur when the ramp rate is reduced to 20ºC per hour and below, then such a problem would not constitute a failu ...
ALS50 Airborne Laser Scanner Product Description
ALS50 Airborne Laser Scanner Product Description

... Interconnecting Cables: Interconnecting cables are permanently restrained at a lower rear corner of the equipment rack, and at appropriate points on the scanner assembly. Retention for remaining portions of the interconnecting cables must be installed by the end user in such a fashion as to prevent ...
STP 3 & 4 8.2  Offsite Power Systems
STP 3 & 4 8.2 Offsite Power Systems

... 3, & 4) toward the termination points described below and shown on Figure 8.2-5. The eastern right-of-way is 100 ft wide and contains two (2) 345 kV circuits to Velasco (on double-circuit structures). The western right-of-way is 100 ft wide and contains a 345 kV circuit to Blessing. The middle or no ...
Evaluates:  MAX2750/MAX2751/MAX2752 MAX2750/MAX2751/MAX2752 Evaluation Kits General Description Features
Evaluates: MAX2750/MAX2751/MAX2752 MAX2750/MAX2751/MAX2752 Evaluation Kits General Description Features

... MAX2750EUA, MAX2751EUA, or MAX2752EUA ...
SIFT Scanner System
SIFT Scanner System

... The simplest method is to monitor the pass-fail light bar on a tester and strobe the SIFT through full test loops. This allows the die to be fully tested at each stimulus coordinate controlled by the SIFT scanner. In the case of figure 12, two sensors are used. The sensor labeled D is the data sens ...
Switching, protection, communication: the new NZM circuit
Switching, protection, communication: the new NZM circuit

... Even under load conditions the Moeller switch-disconnector operates safely. The reason: the 3- or 4-pole snap-action closing mechanism which is also applied with circuit-breakers. That’s why the rated short time withstand current is so high and can handle currents up to 150 000 A. The long lifetime ...
1 - UTRGV Faculty Web
1 - UTRGV Faculty Web

... A common use of cluster computing is to load balance traffic on high-traffic websites. A web page request is sent to a "manager" server (load balancer), which then determines which of several identical or very similar web servers to forward the request to for handling. Having a web farm (as such a c ...
Sepam sales promotion package
Sepam sales promotion package

...  As an option, monitoring of the circuit breaker for maintenance statistics purpose: operating time, charging time, trip circuit supervision (covering power supply, wiring and coil) cumulative total of tripping currents for 5 current ranges, operation counter, pressure (for SF6 circuit breakers)  ...
BDTIC TDA 7210
BDTIC TDA 7210

... contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such compo ...
ADC Presentation - James Cockrell, Justin Loveless
ADC Presentation - James Cockrell, Justin Loveless

Power Electronic Capacitors General Technical Information
Power Electronic Capacitors General Technical Information

Ground Fault Application Guide
Ground Fault Application Guide

MicroVersaTrip Product Safety Alert
MicroVersaTrip Product Safety Alert

motion sensor for secqurity light
motion sensor for secqurity light

... The information presented in this document does not form part of any quotation or contract, it is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any l ...
NRD1-6_Rev.0110 - pes-psrc
NRD1-6_Rev.0110 - pes-psrc

... the frequency and voltage of the generator. See: manual synchronizing system, semiautomatic synchronizing system, synchronizing relay, synchronism check relay. Breaker-and-a-half. A configuration of three circuit breakers in series between two buses with a line, transformer, generator or other circu ...
RWB2 Programmer Inst. ins
RWB2 Programmer Inst. ins

... RWB2 BACKPLATE ...
instruction manual
instruction manual

... Thank you for purchasing the TECHTOM Flash Reprogrammer. Please read and follow the instructions carefully to ensure correct operation of programmer. Misuse of the programmer will result in damage to the ECU. This programmer is design to be used with specific automobile models only - DO NOT try to r ...
Manual - Martindale Electric
Manual - Martindale Electric

... fault of our manufacturing, with no charge for parts and service. If we are unable to repair or replace the product, we will make a refund of the purchase price. Consult the Instruction Manual for instructions regarding the proper use and servicing of instruments and test equipment. Our obligation u ...
Output Short-Circuit Protection Solution for the
Output Short-Circuit Protection Solution for the

24 VDC Interface Card Installation Manual
24 VDC Interface Card Installation Manual

... equipment manufacturer or end user. Magnetek accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any Magnetek product be incorporated into any product or design as the exclusive or sole safety control. Without exception, all ...
GP/IP - Uplift Meridian
GP/IP - Uplift Meridian

... 3. TRUE or FALSE: Three light bulbs are connected in series. The filament of one of the light bulbs burns out. The remaining two light bulbs will still be lit; yet, their brightness will be noticeably less. ...
8-Bit Parallel-Out Serial Shift Register (Rev. D)
8-Bit Parallel-Out Serial Shift Register (Rev. D)

MAX1940 Triple USB Switch with Autoreset and Fault Blanking General Description
MAX1940 Triple USB Switch with Autoreset and Fault Blanking General Description

... Triple USB Switch with Autoreset and Fault Blanking The MAX1940 triple current-limited switch with autoreset supplies a guaranteed 500mA load per channel in accordance with USB specifications. The MAX1940 operates from a 4V to 5.5V input supply and consumes only 60µA of quiescent current when operat ...
Dorman Smith
Dorman Smith

A Tutorial on Calculating Source Impedance Ratios
A Tutorial on Calculating Source Impedance Ratios

... Transmission lines are often protected by distance relays and overcurrent relays. Even when communications-aided schemes are used, such as line current differential or a directional comparison scheme (directional comparison blocking [DCB] or permissive overreaching transfer trip [POTT], for example) ...
< 1 ... 108 109 110 111 112 113 114 115 116 ... 256 >

Fault tolerance



Fault tolerance is the property that enables a system to continue operating properly in the event of the failure of (or one or more faults within) some of its components. If its operating quality decreases at all, the decrease is proportional to the severity of the failure, as compared to a naively designed system in which even a small failure can cause total breakdown. Fault tolerance is particularly sought after in high-availability or life-critical systems.A fault-tolerant design enables a system to continue its intended operation, possibly at a reduced level, rather than failing completely, when some part of the system fails. The term is most commonly used to describe computer systems designed to continue more or less fully operational with, perhaps, a reduction in throughput or an increase in response time in the event of some partial failure. That is, the system as a whole is not stopped due to problems either in the hardware or the software. An example in another field is a motor vehicle designed so it will continue to be drivable if one of the tires is punctured. A structure is able to retain its integrity in the presence of damage due to causes such as fatigue, corrosion, manufacturing flaws, or impact.Within the scope of an individual system, fault tolerance can be achieved by anticipating exceptional conditions and building the system to cope with them, and, in general, aiming for self-stabilization so that the system converges towards an error-free state. However, if the consequences of a system failure are catastrophic, or the cost of making it sufficiently reliable is very high, a better solution may be to use some form of duplication. In any case, if the consequence of a system failure is so catastrophic, the system must be able to use reversion to fall back to a safe mode. This is similar to roll-back recovery but can be a human action if humans are present in the loop.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report