• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
6 pulse vs. 12 and 18 pulse harmonics effect reduction White paper
6 pulse vs. 12 and 18 pulse harmonics effect reduction White paper

... most hvac installations, using VFDs and Sensorless Control™ rarely run at full load current. • The voltages in the recommendation are typically utility voltages and are not necessarily intended to be applied to low voltage installations. • The standard is designed to ensure power quality on the ut ...
HMC344LP3 数据资料DataSheet下载
HMC344LP3 数据资料DataSheet下载

... 16 Lead 3x3mm QFN Package: 9 mm² ...
TPS312x Series Supervisory Circuits in Ultra
TPS312x Series Supervisory Circuits in Ultra

... terminal of the IC may produce uncontrolled currents that flow into the component and cause faulty program execution. These currents may change parts of the circuit to an unwanted state. When the program is unable to detect these unwanted operating states, corrective measures are taken and the watch ...
A novel sensor cell architecture and sensing circuit scheme
A novel sensor cell architecture and sensing circuit scheme

... implementation of high-density circuits is prevented. For this problem too, a sensing circuit scheme that is independent of the parasitic capacitance is essentially needed. Another issue is the need for a wide output dynamic range. To obtain a clear fingerprint image, the analog signals from the sen ...
MAX9375 Single LVDS/Anything-to-LVPECL Translator General Description Features
MAX9375 Single LVDS/Anything-to-LVPECL Translator General Description Features

... The MAX9375 outputs are emitter followers that require external resistive paths to a voltage source (VT = VCC - 2.0V typ) more negative than worst-case VOL for proper ...
TPS43000 数据资料 dataSheet 下载
TPS43000 数据资料 dataSheet 下载

... The device mode is controlled by the CCM and PFM pins. The CCM pin lets the user decide whether to allow DCM by connecting the pin to ground or to force CCM by connecting the pin to VIN. The PFM pin lets the user decide whether to allow automatic PFM by connecting the pin to ground or to force fixed ...
Discussion #17 - Operational Amplifiers
Discussion #17 - Operational Amplifiers

CHAPTER 2: Diode Applications (Aplikasi Diod)
CHAPTER 2: Diode Applications (Aplikasi Diod)

... Power supply is a group of circuits that convert the standard ac voltage (120 V, 60 Hz) provided by the wall outlet to constant dc voltage. The voltage produced is used to power all types of electronic circuits including: Consumer electronics (ex: radio, television, DVD, etc.) Computers Industrial c ...
John H. Scofield, Rev. Sci. Instrum. 58
John H. Scofield, Rev. Sci. Instrum. 58

ADP2105 数据手册DataSheet 下载
ADP2105 数据手册DataSheet 下载

... No Connect. This is not internally connected and can be connected to other pins or left unconnected. Power Source Inputs. The source of the PFET high-side switch. Bypass each PWIN pin to the nearest PGND plane with a 4.7 μF or greater capacitor as close as possible to the ADP2105/ADP2106/ ADP2107. S ...
Cap-Free NMOS 250mA Lower Dropout
Cap-Free NMOS 250mA Lower Dropout

... stability, it is good analog design practice to connect a 0.1 µF to 1 µF low ESR capacitor across the input supply near the regulator. This counteracts reactive input sources and improves transient response, noise rejection, and ripple rejection. A higher-value capacitor may be necessary if large, f ...
P83177
P83177

... NOTE: This equipment has been tested and found to comply with the limits for a Class B digital appliance, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can ...
DEC Module 50/5 Operating Instructions
DEC Module 50/5 Operating Instructions

Amplifier Modelling
Amplifier Modelling

... ROUT is the Norton resistance seen at the output terminals and is called the output resistance of the amplifier  AIIIN is the Norton current produced at the output of the amplifier where AI is the current gain of the amplifier. ...
LT3505 - 1.2A, Step-Down Switching Regulator in 3mm x 3mm DFN
LT3505 - 1.2A, Step-Down Switching Regulator in 3mm x 3mm DFN

Owner`s Manual - On Board Solutions
Owner`s Manual - On Board Solutions

... 3. Hold the inverter against the mounting surface, mark the position of the mounting screws, and then remove the inverter. 4. Drill pilot holes for the four mounting fasteners. 5. Fasten the inverter to the mounting surface with four #10 hardware fasteners. Mount your inverter prior to connecting an ...
A METHOD FOR CHARACTERIZATION OF THREE
A METHOD FOR CHARACTERIZATION OF THREE

... voltage V ) can be used to characterize three-phase unbalanced dips without loss of essential information. Using characteristic magnitude and duration for three-phase unbalanced dips, corresponds to the existing classification (through magnitude and duration) for single-phase equipment. Where needed ...
Chapter4 DC Biasing BJT (part a)
Chapter4 DC Biasing BJT (part a)

... currents. With the dc load line superimposed across the collector curves for this particular transistor we see that 30 mA (IB = 300 A) of collector current is best for maximum amplification, giving equal amount above and below the Q-point. Note that this is three different scenarios of collector cu ...
- Legrand
- Legrand

... half involve a range of causes including contact with overhead lines or lightning. When electric current passes through the body the victim “cannot let go” (tetanisation of the hands on the area with which they are in contact), or the reverse happens and the muscles relax, causing him/her to be thro ...
MAX1955/MAX1956 1.6V to 5.5V Input, 0.5% Accurate, Dual 180° Out-of-Phase Step-Down Controllers
MAX1955/MAX1956 1.6V to 5.5V Input, 0.5% Accurate, Dual 180° Out-of-Phase Step-Down Controllers

... IN, AVDD, SYNC, EN, ILIM_, FB_, SEQ to GND.......-0.3V to +6V COMP_, REF to GND..............................-0.3V to (VAVDD + 0.3V) LXB to GND ..............................................-0.3V to (VVDD + 0.3V) DL_ to GND ...............................(VPGND - 0.3V) to (VVDD + 0.3V) BST_ to GND . ...
Farm Pro Pig Installation Manual
Farm Pro Pig Installation Manual

... Avoid mixing high voltage wiring with sensor and low voltage wiring. Keep the controller as far as possible from heavy contactor boxes and other sources of electrical interference. • Do not connect communication wire shields, which go from one house to another at both ends. Connect them at one end o ...
installation manual
installation manual

... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ...
CHAPTER 2: Diode Applications (Aplikasi Diod)
CHAPTER 2: Diode Applications (Aplikasi Diod)

... - A diode clamper adds a DC level to an AC voltage. The capacitor charges to the peak of the supply minus the diode drop. Once charged, the capacitor acts like a battery in series with the input voltage. The AC voltage will “ride” along with the DC voltage. The polarity arrangement of the diode dete ...
GMC-RM001A-EN-P System Design for Control of Electrical Noise
GMC-RM001A-EN-P System Design for Control of Electrical Noise

Selecting the Right Cable System for Your Environment
Selecting the Right Cable System for Your Environment

< 1 ... 36 37 38 39 40 41 42 43 44 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.