• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
2ch High Side Switch ICs for USB Devices and Memory Cards Datasheet
2ch High Side Switch ICs for USB Devices and Memory Cards Datasheet

... When excessive current flows due to output short-circuit or so, ringing occurs because of inductance between power source lines to IC, and may cause bad influences on IC operations. In order to avoid this case, connect a bypass capacitor across IN terminal and GND terminal of IC. 1μF or higher is re ...
SERVICE MANUAL
SERVICE MANUAL

... tube before handling the tube. The picture tube is highly evacuated and if broken. Glass fragments will be violently expelled. Always discharge the picture tube anode to the receiver chassis to keep of the shock hazard before removing the anode cap. 8- Keep wire away from the high voltage or high te ...
Radio Frequency CMOS Transmitter - FM UWB
Radio Frequency CMOS Transmitter - FM UWB

PXIe-4302/4303 RM-4302 User Guide and RM
PXIe-4302/4303 RM-4302 User Guide and RM

Datasheet - Diodes Incorporated
Datasheet - Diodes Incorporated

AN2690
AN2690

17 Interface Circuitry and Microsystems
17 Interface Circuitry and Microsystems

... converts the quantity to be measured into an electrical signal, such as a voltage, a current, or a resistive or capacitive variation. The data obtained from the transducers then have to be translated into a form understandable by humans, computers, or measurement systems. An electronic circuit calle ...
Pluto Servo Drive - Product Manual
Pluto Servo Drive - Product Manual

... To prevent the formation of electric arcs, as well as dangers to personnel and electrical contacts, never connect/disconnect the Pluto Servo Drive while the power supply is on. Power cables may be exposed to high voltages, even when the motor is not in motion. Disconnect the Pluto Servo Drive from a ...
3-Channel, Low-Leakage ESD Protector MAX14541E
3-Channel, Low-Leakage ESD Protector MAX14541E

test to prove de-energised cs-ohs-54
test to prove de-energised cs-ohs-54

HMC347G8 数据资料DataSheet下载
HMC347G8 数据资料DataSheet下载

... List of Materials for Evaluation PCB 107261 [1] Item ...
MAX2023 High-Dynamic-Range, Direct Up-/Downconversion 1500MHz to 2500MHz Quadrature Mod/Demod General Description
MAX2023 High-Dynamic-Range, Direct Up-/Downconversion 1500MHz to 2500MHz Quadrature Mod/Demod General Description

... ♦ 0.025dB Typical I/Q Gain Imbalance ♦ 0.56° I/Q Typical Phase Imbalance ...
Magnetics Booklet v.3
Magnetics Booklet v.3

... Let’s first note that there are three major areas of the market we will focus on: Power Applications, LAN/ Telecom Applications, and Broadband/RF Applications (high frequency applications which some classify certain DSL applications in this market, opposed to Telecom, but this training will primaril ...
Circuit Breakers - Single Pole Interrupting Capability
Circuit Breakers - Single Pole Interrupting Capability

... 240.85 FPN: Proper application of molded case circuit breakers on 3-phase systems, other than solidly grounded wye, particularly on corner grounded delta systems, considers the circuit breakers’ individual pole interrupting capability. 430.52(C)(6) FPN: Proper application of self protected combinati ...
Guide to Portable Appliance Testing
Guide to Portable Appliance Testing

... grounding system for safety protection. If the earth conductor within the power cable is damaged, the hazard rises and will, therefore, require electrical testing on a more regular basis. Operators: If the equipment is likely to receive constant unreported abuse, more frequent testing will be requir ...
How To Cut Downtime And Extend Cable Life Underground mining cable care
How To Cut Downtime And Extend Cable Life Underground mining cable care

... Grounding conductors and shielding wires cannot be separated from each other when considering effective ground impedance, because together they form the total grounding system. As a result, little change occurs in the grounding system impedance after individual components have suffered extreme flex ...
Paper Title - Radio Frequency Research Group
Paper Title - Radio Frequency Research Group

... body, HBC has the characteristics of low interference, high security, and low power consumption [3]. Overall, these aspects make HBC specially suitable for body area networks, being presented as one of the tree PHY (physical layer) covered by the IEEE 802.15.6 standard [4]. ...
MAX1878 Dual-Output Step-Down and LCD Step-Up Power Supply for PDAs General Description
MAX1878 Dual-Output Step-Down and LCD Step-Up Power Supply for PDAs General Description

... sources, such as lithium ion and alkaline cells. Step-down converter soft-start is implemented with current limit. At startup the step-down converter current limit is set to 25% of its full current limit. The current limit is increased by 25% every 256 switching cycles until full current limit is re ...
BDTIC
BDTIC

... PRIMECELL™, REALVIEW™, THUMB™, µVision™ of ARM Limited, UK. AUTOSAR™ is licensed by AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microso ...
Brushless DC Motor Controller (Rev. B)
Brushless DC Motor Controller (Rev. B)

Course Outline Basic Concepts in RF Design Low
Course Outline Basic Concepts in RF Design Low

... amplitude of 2V0 and IF amplitude of (1/π)2V0. Since they are 180 ° out of phase, the Vout1-Vout2 contains an IF amplitude of (1/π)(4V0).  The peak differential input is equal to 2V0  the voltage conversion gain is 2/π, equal to that of the single-balanced counterpart. It is possible to apply a s ...
BD9428
BD9428

... The REG100 pin is used in the DC/DC converter driver block to output 10V power. The maximum operating current is 15mA. Using the REG100 pin at a current higher than 15mA can affect the N pin output pulse, causing the IC to malfunction and leading to heat generation of the IC itself. To avoid this pr ...
ENERGY CONVERSION ONE
ENERGY CONVERSION ONE

MAX5717,19 Datasheet - Maxim Part Number Search
MAX5717,19 Datasheet - Maxim Part Number Search

Transformer Voltage Regulation and Efficiency
Transformer Voltage Regulation and Efficiency

... as an autotransformer due to the fact that insulation of L.V. side may not withstand full output voltage of autotransformer connection Common practice: to use autotransformer when two voltages fairly close Also used as variable transformers, where L.V. tap moves up & down the winding Disadvantage: d ...
< 1 ... 38 39 40 41 42 43 44 45 46 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report