2ch High Side Switch ICs for USB Devices and Memory Cards Datasheet
... When excessive current flows due to output short-circuit or so, ringing occurs because of inductance between power source lines to IC, and may cause bad influences on IC operations. In order to avoid this case, connect a bypass capacitor across IN terminal and GND terminal of IC. 1μF or higher is re ...
... When excessive current flows due to output short-circuit or so, ringing occurs because of inductance between power source lines to IC, and may cause bad influences on IC operations. In order to avoid this case, connect a bypass capacitor across IN terminal and GND terminal of IC. 1μF or higher is re ...
SERVICE MANUAL
... tube before handling the tube. The picture tube is highly evacuated and if broken. Glass fragments will be violently expelled. Always discharge the picture tube anode to the receiver chassis to keep of the shock hazard before removing the anode cap. 8- Keep wire away from the high voltage or high te ...
... tube before handling the tube. The picture tube is highly evacuated and if broken. Glass fragments will be violently expelled. Always discharge the picture tube anode to the receiver chassis to keep of the shock hazard before removing the anode cap. 8- Keep wire away from the high voltage or high te ...
17 Interface Circuitry and Microsystems
... converts the quantity to be measured into an electrical signal, such as a voltage, a current, or a resistive or capacitive variation. The data obtained from the transducers then have to be translated into a form understandable by humans, computers, or measurement systems. An electronic circuit calle ...
... converts the quantity to be measured into an electrical signal, such as a voltage, a current, or a resistive or capacitive variation. The data obtained from the transducers then have to be translated into a form understandable by humans, computers, or measurement systems. An electronic circuit calle ...
Pluto Servo Drive - Product Manual
... To prevent the formation of electric arcs, as well as dangers to personnel and electrical contacts, never connect/disconnect the Pluto Servo Drive while the power supply is on. Power cables may be exposed to high voltages, even when the motor is not in motion. Disconnect the Pluto Servo Drive from a ...
... To prevent the formation of electric arcs, as well as dangers to personnel and electrical contacts, never connect/disconnect the Pluto Servo Drive while the power supply is on. Power cables may be exposed to high voltages, even when the motor is not in motion. Disconnect the Pluto Servo Drive from a ...
MAX2023 High-Dynamic-Range, Direct Up-/Downconversion 1500MHz to 2500MHz Quadrature Mod/Demod General Description
... ♦ 0.025dB Typical I/Q Gain Imbalance ♦ 0.56° I/Q Typical Phase Imbalance ...
... ♦ 0.025dB Typical I/Q Gain Imbalance ♦ 0.56° I/Q Typical Phase Imbalance ...
Magnetics Booklet v.3
... Let’s first note that there are three major areas of the market we will focus on: Power Applications, LAN/ Telecom Applications, and Broadband/RF Applications (high frequency applications which some classify certain DSL applications in this market, opposed to Telecom, but this training will primaril ...
... Let’s first note that there are three major areas of the market we will focus on: Power Applications, LAN/ Telecom Applications, and Broadband/RF Applications (high frequency applications which some classify certain DSL applications in this market, opposed to Telecom, but this training will primaril ...
Circuit Breakers - Single Pole Interrupting Capability
... 240.85 FPN: Proper application of molded case circuit breakers on 3-phase systems, other than solidly grounded wye, particularly on corner grounded delta systems, considers the circuit breakers’ individual pole interrupting capability. 430.52(C)(6) FPN: Proper application of self protected combinati ...
... 240.85 FPN: Proper application of molded case circuit breakers on 3-phase systems, other than solidly grounded wye, particularly on corner grounded delta systems, considers the circuit breakers’ individual pole interrupting capability. 430.52(C)(6) FPN: Proper application of self protected combinati ...
Guide to Portable Appliance Testing
... grounding system for safety protection. If the earth conductor within the power cable is damaged, the hazard rises and will, therefore, require electrical testing on a more regular basis. Operators: If the equipment is likely to receive constant unreported abuse, more frequent testing will be requir ...
... grounding system for safety protection. If the earth conductor within the power cable is damaged, the hazard rises and will, therefore, require electrical testing on a more regular basis. Operators: If the equipment is likely to receive constant unreported abuse, more frequent testing will be requir ...
How To Cut Downtime And Extend Cable Life Underground mining cable care
... Grounding conductors and shielding wires cannot be separated from each other when considering effective ground impedance, because together they form the total grounding system. As a result, little change occurs in the grounding system impedance after individual components have suffered extreme flex ...
... Grounding conductors and shielding wires cannot be separated from each other when considering effective ground impedance, because together they form the total grounding system. As a result, little change occurs in the grounding system impedance after individual components have suffered extreme flex ...
Paper Title - Radio Frequency Research Group
... body, HBC has the characteristics of low interference, high security, and low power consumption [3]. Overall, these aspects make HBC specially suitable for body area networks, being presented as one of the tree PHY (physical layer) covered by the IEEE 802.15.6 standard [4]. ...
... body, HBC has the characteristics of low interference, high security, and low power consumption [3]. Overall, these aspects make HBC specially suitable for body area networks, being presented as one of the tree PHY (physical layer) covered by the IEEE 802.15.6 standard [4]. ...
MAX1878 Dual-Output Step-Down and LCD Step-Up Power Supply for PDAs General Description
... sources, such as lithium ion and alkaline cells. Step-down converter soft-start is implemented with current limit. At startup the step-down converter current limit is set to 25% of its full current limit. The current limit is increased by 25% every 256 switching cycles until full current limit is re ...
... sources, such as lithium ion and alkaline cells. Step-down converter soft-start is implemented with current limit. At startup the step-down converter current limit is set to 25% of its full current limit. The current limit is increased by 25% every 256 switching cycles until full current limit is re ...
BDTIC
... PRIMECELL™, REALVIEW™, THUMB™, µVision™ of ARM Limited, UK. AUTOSAR™ is licensed by AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microso ...
... PRIMECELL™, REALVIEW™, THUMB™, µVision™ of ARM Limited, UK. AUTOSAR™ is licensed by AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microso ...
Course Outline Basic Concepts in RF Design Low
... amplitude of 2V0 and IF amplitude of (1/π)2V0. Since they are 180 ° out of phase, the Vout1-Vout2 contains an IF amplitude of (1/π)(4V0). The peak differential input is equal to 2V0 the voltage conversion gain is 2/π, equal to that of the single-balanced counterpart. It is possible to apply a s ...
... amplitude of 2V0 and IF amplitude of (1/π)2V0. Since they are 180 ° out of phase, the Vout1-Vout2 contains an IF amplitude of (1/π)(4V0). The peak differential input is equal to 2V0 the voltage conversion gain is 2/π, equal to that of the single-balanced counterpart. It is possible to apply a s ...
BD9428
... The REG100 pin is used in the DC/DC converter driver block to output 10V power. The maximum operating current is 15mA. Using the REG100 pin at a current higher than 15mA can affect the N pin output pulse, causing the IC to malfunction and leading to heat generation of the IC itself. To avoid this pr ...
... The REG100 pin is used in the DC/DC converter driver block to output 10V power. The maximum operating current is 15mA. Using the REG100 pin at a current higher than 15mA can affect the N pin output pulse, causing the IC to malfunction and leading to heat generation of the IC itself. To avoid this pr ...
Transformer Voltage Regulation and Efficiency
... as an autotransformer due to the fact that insulation of L.V. side may not withstand full output voltage of autotransformer connection Common practice: to use autotransformer when two voltages fairly close Also used as variable transformers, where L.V. tap moves up & down the winding Disadvantage: d ...
... as an autotransformer due to the fact that insulation of L.V. side may not withstand full output voltage of autotransformer connection Common practice: to use autotransformer when two voltages fairly close Also used as variable transformers, where L.V. tap moves up & down the winding Disadvantage: d ...