• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Basics of Switchboards
Basics of Switchboards

... Switchboard Definition............................................................ 9 Switchboard Construction..................................................... 12 ...
Seminar Report
Seminar Report

Understanding Operational Amplifier
Understanding Operational Amplifier

... relevant information to verify, before placing orders, that the information being relied on is current. TI warrants performance of its semiconductor products and related software to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality ...
Small Footprint PicoGuard XS® ESD Clamp Array For High Speed Data Line Protection
Small Footprint PicoGuard XS® ESD Clamp Array For High Speed Data Line Protection

... PicoGuard is a registered trademark of Semiconductor Components Industries, LLC. ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, rep ...
Next Topic: NOISE
Next Topic: NOISE

Amplification of biosignals by body potential driving. Analysis of the
Amplification of biosignals by body potential driving. Analysis of the

... earth and the signal earth are assumed to be the same. Possible values of the model elements are shown. The body will be considered an equipotential surface (lumped at a point B). Only the displacement current Ib through the body will be of interest. R I and CI are essential. They ensure the BPD sta ...
Fuses – Introductory Information
Fuses – Introductory Information

... In all cases, the next higher rated current of the fuse type must be chosen. In a next step, any fault situations have to be verified, i.e. whether the operating time of the selected fuse is sufficiently short under overcurrent conditions. For inrush pulses (particularly in the case of switching pow ...
Calculating noise figure in op amps
Calculating noise figure in op amps

Loadbreaking and the Bazooms Curve
Loadbreaking and the Bazooms Curve

... pressures were developed at the instant of fault close. Successful closures did not exhibit such pressures. Instrumentation was then introduced to determine the real time position of the probe and bushing connector during fault close. While the actual circuit current and voltage were available from ...
4.5V to 18V Input Voltage, 3A/2A/2A Output Current Triple
4.5V to 18V Input Voltage, 3A/2A/2A Output Current Triple

... The TPS65261, TPS65261-1 features an automatic power sequence with connecting MODE pin to V7V and configuring EN1/2/3 pins. The device also features an open drain RESET signal to monitor power down. At light load, the TPS65261 automatically operates in pulse skipping mode (PSM) and the TPS65261-1 op ...
BD35395FJ-M
BD35395FJ-M

... This IC has a built-in thermal shutdown circuit that prevents heat damage to the IC. Normal operation should always be within the IC’s power dissipation rating. If however the rating is exceeded for a continued period, the junction temperature (Tj) will rise which will activate the TSD circuit that ...
4-channel BTL driver for CD players and CD-ROM
4-channel BTL driver for CD players and CD-ROM

... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger ...
OSHA 29 CFR 1910.333, Selection and Use of Work Practices
OSHA 29 CFR 1910.333, Selection and Use of Work Practices

... "Deenergized parts." Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Li ...
Article - Voltage Clamp Techniques
Article - Voltage Clamp Techniques

Chapter 5 Protection Circuit Design
Chapter 5 Protection Circuit Design

Victoreen
Victoreen

... The Victoreen® Model 943-227-15 Digital Preamplifier, is designed to operate with the Model 943-27, Current Mode Beta Scintillation detector and the Model 942A-200C Series Digital Ratemeter (UDR) or the Model 960 Series Digital Process Control system. When connected to the beta sensitive scintillati ...
Technical Requirements for Subsea High Voltage Direct
Technical Requirements for Subsea High Voltage Direct

... Subsea cable connectors: AC vs. DC Insulation AC Insulation DC Insulation Field is capacitive graded, i.e., determined by dielectric constant, which for typical ac insulation, is nearly independent of field & temperature :  ...
MAX8884Y/MAX8884Z 700mA DC-DC Step-Down Converters General Description
MAX8884Y/MAX8884Z 700mA DC-DC Step-Down Converters General Description

... Wi-Fi modules, or other point of load applications in portable devices. These ICs feature high efficiency with small external component size. The step-down converter output voltage is pin selectable between 1.2V and 1.8V, and provides guaranteed output current of 700mA. The 2/4MHz hysteretic-PWM con ...
Supplementary Information for
Supplementary Information for

... the expectation for a conventional FET charge sensing mechanism in which any increase of buffer concentration will reduce the FET signal due to the shorter screening length. In this comparison, we exclude channel-3 FET in main Figure 4 because the long translocation times are indicative of contamina ...
The Polarization Cell Replacement (PCR)
The Polarization Cell Replacement (PCR)

LT1942
LT1942

... LEDs are used, ILED is the sum of the current in the two strings. If only a single string of LEDs is used, ILED is simply the single string current. For dimming LED current, drive VCTRL4 to a lower voltage. See the Applications Section for more information. ...
Power Line
Power Line

... instruction. Trainees study the material and complete assignment sheets at the end of each unit, checking their answers in the back of the workbook. Trainees take a section test when they are ready, or on a schedule set by their training coordinator. The rate at which a trainee progresses through th ...
Mini MegaPAC User Guide
Mini MegaPAC User Guide

A New Algorithm for Digital Low-impedance Protection of Busbars
A New Algorithm for Digital Low-impedance Protection of Busbars

... • Distributed busbar protection uses DAUs installed in each bay to sample and pre-process the signals and provide trip rated output contacts. It uses a separate Central Unit (CU) for gathering and processing all the information and fiber-optic communications between the CU and DAUs to deliver the da ...
S270-15-2
S270-15-2

... confine outages to smaller sections of line. The sectionalizer does not interrupt fault current but can be closed into a faulted line. It opens during the open interval of the backup device. For this reason, it must always be used in series with a fault-interrupting, backup protective reclosing devi ...
< 1 ... 40 41 42 43 44 45 46 47 48 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.