• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Noise, Digital Resolution, and Accuracy in Digital
Noise, Digital Resolution, and Accuracy in Digital

ALTERNATING CURRENT CIRCUITS Capacitors and Capacitive
ALTERNATING CURRENT CIRCUITS Capacitors and Capacitive

The Use And Misuse Of Circuit Protection Devices
The Use And Misuse Of Circuit Protection Devices

... induced by indirect strikes), or simply by the switching of power systems with resulting load changes and short-circuit switching. At lower levels (500 V to 1 kV), these transients occur in industrial automation. At higher levels (5 to 6 kV), they occur in power grid systems. In either case, due to ...
LM6172 - Brandeis
LM6172 - Brandeis

Using Your SMT Micro Anodizer
Using Your SMT Micro Anodizer

Copper Cabling
Copper Cabling

US19746 Element 1 - cashmerescience12and13
US19746 Element 1 - cashmerescience12and13

Simulating Control System Operations
Simulating Control System Operations

Analog Devices Welcomes Hittite Microwave Corporation
Analog Devices Welcomes Hittite Microwave Corporation

KFD2-CD-Ex1.32-** Current/Voltage Driver Connection Assembly
KFD2-CD-Ex1.32-** Current/Voltage Driver Connection Assembly

... A current limit circuit in series to terminal 9 protects the device from damage. The max. voltage drop at the input is DC 4 V, allowing for the connection of several KFD2-CD32-Ex1.32 repeaters due to the low voltage drop in order to maintain multiple galvanically isolated outputs (signal duplication ...
hw11
hw11

... Problem 3: MOSFET Sub-Threshold Current In a complementary metal-oxide-semiconductor (CMOS) digital logic circuit, power is consumed in steady state (when neither the input voltages nor the output voltage are changing with time) due to transistor off-state leakage current IOFF, i.e. the current whic ...
4. Preamplifier near CCD - Caltech Optical Observatories
4. Preamplifier near CCD - Caltech Optical Observatories

... preamp changes linearly as the AC coupling capacitor integrates the input bias current of the preamp and switch leakage current. To the extent that these currents and the coupling capacitors match, this produces a common mode ramp, which is rejected by the differential ADC buffer. Given typical val ...
H3CA full 12.01
H3CA full 12.01

... cycle, Signal Interval/OFF-delay, Signal-OFF delay (I and II), Interval, Cycle and Signal ON-delay/OFF-delay ■ Selectable no-voltage start, reset, gate and check inputs expand capabilities ■ Time remaining LCD bar graph and LCD output status indicator ■ Panel mounting adapters, sockets, and accessor ...
Transformers
Transformers

Power Integrations
Power Integrations

... 9) Capacitor C4 should be connected directly to TOPSwitch Source pin with no other traces connected to this trace segment. No other components should be connected to this trace segment because lightning surge test voltages will induce noise voltage drops. 10) Capacitor C5 should be connected directl ...
FML10
FML10

... (such as audio visual equipment, office-automation equipment, communications devices, electrical appliances and electronic toys). Should you intend to use these products with equipment or devices which require an extremely high level of reliability and the malfunction of with would directly endanger ...
DC Circuits - Rutgers Physics
DC Circuits - Rutgers Physics

TDA9103 USER`S MANUAL DEMONSTRATION BOARD
TDA9103 USER`S MANUAL DEMONSTRATION BOARD

... by X-ray protection, Q2 will remain conductive, which causes high dissipation in R47. This may be solved if AC coupling is used between pin 21 and driver stage Q1-Q10. This was not implemented on present board. III.4 - DC/DC Converter Section III.4.1 - Keeping the Information Clean The converter sec ...
Flash ADC Lab
Flash ADC Lab

... Name:________________ ...
Intro. To Electricity and Electrical Safety
Intro. To Electricity and Electrical Safety

Electrical Safety
Electrical Safety

Electric Service Requirements - Singing River Electric Power
Electric Service Requirements - Singing River Electric Power

... shall be easily accessible and shall not be covered by concrete or any other substance. 2. The ground clamp must be U.L. approved type for service entrance grounding. Disconnect Devices Shall Conform to the NEC as follows: 1. The disconnecting means shall consist of not more than six switches, circu ...
Analog Devices Welcomes Hittite Microwave Corporation
Analog Devices Welcomes Hittite Microwave Corporation

... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
DA100J Series - Murata Power Solutions
DA100J Series - Murata Power Solutions

... i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously ...
Dup Dup - Bastl Instruments
Dup Dup - Bastl Instruments

... Double check the polarity of the ribbon cable and that it is not shifted in any direction. The red cable should be attached to the -12V rail, both on the module and on the bus board side! Although we put protection circuits in the device, we do not take any responsibility for damages caused by wrong ...
< 1 ... 221 222 223 224 225 226 227 228 229 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report