• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Leakage Current Abstract Leakage current is the current that flows
Leakage Current Abstract Leakage current is the current that flows

Data Sheet (current)
Data Sheet (current)

Printable Version of Questions for Evaluation Test
Printable Version of Questions for Evaluation Test

... 82. A center pivot irrigation machine may have hand-portable motors. True or False 83. What is the minimum size copper equipment grounding conductor required for a 400 ampere branch circuit? The ungrounded conductors are sized using an adjusted value from the 90 C column of T310.16. The ungrounded c ...
Evaluating Critical VFD Cable Parameters
Evaluating Critical VFD Cable Parameters

Document
Document

Notes
Notes

Nonlinear Circuits - Oklahoma State University
Nonlinear Circuits - Oklahoma State University

... A fact about any real switching element is that, when they are turned off, a finite amount of time must pass before current flow ceases. This applies to real diodes as well: if they are conducting current in a forward direction, and the applied voltage polarity is suddenly switched, the diode will n ...
Analog and Mixed Signal Circuits On Digital CMOS Processes
Analog and Mixed Signal Circuits On Digital CMOS Processes

... Circuits going outside the IC will usually have increased noise coupling. Designs should review the need to exit the IC and minimize the use of external signals. Any noise sensitive signal should have a minimal amount of routing attached. Common examples are: VCO inputs in phase locked loops, compar ...
SIGNALS AND NOISE
SIGNALS AND NOISE

... you alive. If something goes horribly wrong inside one of those devices and winds up connecting the 120 V AC from the wall to the box (chassis) itself, and you come along and touch the front panel while standing in a pool of water, YOU are the path to ground. This is bad. So, the manufacturers put a ...
E-96
E-96

... b. Working with the original circuit (not the Thevenin equivalent) show that IN = 3 A. IN is the short circuit current through RL.. To find it we once again use KCL at A. Once again both current sources flow into A, but with RL = 0 we have At A: 5 + (100 – VA)/400 = VA/300 or 2100 – VA = (4/3)VA Sol ...
Alternator Wiring Upgrade
Alternator Wiring Upgrade

... I strongly suggest using the Optima "red top" battery with this mod. It makes all the difference by eliminating internal resistances and makes charging much easier. You can also get the Optima battery under the Interstate battery label for a few dollars less. My local stereo shop fabricated these wi ...
Bulletin 64-3-*Voltage rating of a photovoltaic source circuit
Bulletin 64-3-*Voltage rating of a photovoltaic source circuit

... Note: This Rule is applicable to installations located on the roof of residential multi-dwelling unit buildings, provided the roof of the building does not also form the roof of the uppermost dwelling units, with access restricted to authorized personnel only. ...
The DatasheetArchive - Datasheet Search Engine
The DatasheetArchive - Datasheet Search Engine

... Note 1: ‘‘Absolute Maximum Ratings’’ are those values beyond which the safety of the device cannot be guaranteed. Except for ‘‘Operating Temperature Range’’ they are not meant to imply that the devices should be operated at these limits. The table of ‘‘Electrical Characteristics’’ provides condition ...
Chapter 13: Inductance and Inductors
Chapter 13: Inductance and Inductors

Slide 1
Slide 1

... - A type of interference caused by signals from one circuit being coupled into adjacent circuits. In electronics, the term crosstalk (XT) refers to any phenomenon by which a signal transmitted on one circuit or channel of a transmission system creates an undesired effect in another circuit or channe ...
File - BCS-2C
File - BCS-2C

... • The direction of the current has no effect on the behavior of the resistor. Resistors behave essentially the same way in both DC and AC circuits. ...
Low voltage high resistance grounding systems
Low voltage high resistance grounding systems

doc
doc

... P3. With the voltage regulator working, you are now ready to power-up the rest of the PCB.  Carefully slide the shorting jumper over the two J21 header pins: this will connect 5 volts from the regulator to the Vcc supply bus on the board. This should illuminate LED1, located in the lower right of t ...
Radiation-hard ASICs for optical data transmission in the ATLAS pixel...
Radiation-hard ASICs for optical data transmission in the ATLAS pixel...

Giving Delta-Sigma Converters a Gain Boost with a Front End Analog Gain Stage
Giving Delta-Sigma Converters a Gain Boost with a Front End Analog Gain Stage

... placing tough requirements on the electronics in the remainder of the signal path. If a high level of accuracy is required in these data acquisition systems, the effective signal fullscale range must be decreased making the signal-to-noise ratio (SNR) higher. Several techniques, in the digital domai ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... supply be decoupled only once. The AD5522 should have ample supply decoupling of 10 μF in parallel with 0.1 μF on each supply located as close to the package as possible, ideally right up against the device. The 10 μF capacitors are the tantalum bead type. The 0.1 μF capacitors should have low effec ...
TECHNICAL NOTES SPECIFICATIONS: TECHNICAL SUPPORT
TECHNICAL NOTES SPECIFICATIONS: TECHNICAL SUPPORT

... technology, which changed the physical appearance of the keypad electronics. The LED’s changed to surface mount chip LED’s mounted on bottom of the circuit board which eliminates the need for the wire harnesses. It is also possible to control the red and green chip LED’s externally, with an alarm pa ...
How to do an optimum setup for the MCA527 24.9.2013 Jörg Brutscher
How to do an optimum setup for the MCA527 24.9.2013 Jörg Brutscher

... half the integration time, so a shaping time of 1µs means that 2µs (=20sample values) before and 2µs after the signal rise are used to calculate the amplitude value. Optimum shaping time depends on the noise characteristic of the detector and further there is a trade off between resolution and high ...
V350-35-T2 - PL Systems
V350-35-T2 - PL Systems

... Do not force the board into place; doing so may damage the controller. 2. Replace the back cover of the controller and fasten the corner ...
A1-102/A1-104 Alternators
A1-102/A1-104 Alternators

... With engine running, disconnect plug between alternator and regulator and momentarily touch the male terminal (E1) from the alternator plug to the negative output stud (E2) on the alternator (Figure E). Caution: Touching regulator terminal to the negative output stud must be rapid to avoid possible ...
< 1 ... 217 218 219 220 221 222 223 224 225 ... 326 >

Ground loop (electricity)

In an electrical system, a ground loop is an equipment and wiring configuration which results in excessive unwanted current in a conductor connecting two points that are supposed to be at the same electric potential, often ground, but are actually at different potentials.Ground loops are a major cause of noise, hum, and interference in audio, video, and computer systems. They do not in themselves create an electric shock hazard, the inappropriate connections merely create a not necessarily very good instance of Electrical_bonding, which is explicitly required by safety regulations in certain circumstances. In any case the voltage difference between the ground terminals of each item of equipment is small. A severe risk of electric shock occurs when equipment grounds are improperly removed in an attempt to cure the problems thought to be caused by ground loops.