• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
model vd-500a capacitive voltage divider
model vd-500a capacitive voltage divider

... calibration is for use in oil, which has a dielectric constant of about 2.3. If the unit is used in air, its division ratio will be approximately 23000:1, but if this is the intended use, a factory calibration of 10000:1 in air would be more accurate and desirable. The maximum pulse voltage rating f ...
Olsun Electrics
Olsun Electrics

... C (104F) and with an average daily ambient temperature not exceeding 30 C (86F). If these ambient temperatures are exceeded, contact the manufacturer. (c) If mounted on or against a wall, provide sufficient clearance for free flow of air to provide adequate cooling and to eliminate fire hazard. ...
I-GARD CORPORATION I-Gard Corporation PARTNER IN GROUND FAULT PROTECTION August 2014
I-GARD CORPORATION I-Gard Corporation PARTNER IN GROUND FAULT PROTECTION August 2014

... The majority of industrial facilities that experience arcing ground faults should not continue to operate without adequate Ground Fault Protection. These establishments typically operate an ungrounded or solidly grounded electrical distribution system, both of which have inherent disadvantages. The ...
Electronics_exercises_files/extra 2
Electronics_exercises_files/extra 2

... SUGGESTED EXERCISES 3 Problem 1 The bias circuit below is used in a design with VG=5V and RS=1kΩ. For an enhancement MOSFET with kn’(W/L) =2mA/V2, the source voltage was measured and found to be 2V. What must Vt be for this device? If a device for which Vt is 0.5V less is used, what does Vs become? ...
chapter 7 - Portal UniMAP
chapter 7 - Portal UniMAP

... surge protection equipment. While some utilities install surge suppression equipment on their distribution lines it is still necessary for the customer to install equipment in their home or business. Wiring solutions include using special circuit and grounding practices. Properly designed transmissi ...
DND5057 - pes-psrc
DND5057 - pes-psrc

... Four-reactor scheme. A shunt reactor arrangement consisting of three wye-connected reactors and a fourth connected from neutral to ground. GPS time synchronization. A method of using a time signal from the Global Positioning System (GPS) satellite system for time-synchronizing equipment. Ground faul ...
PAT testing IT equipment
PAT testing IT equipment

... Functional earthed equipment (ITE) Some IT products have a PSU that appears to be an earthed Class 1 device with an IEC 3 pin socket, but when PAT tested as such, the device fails the bond / continuity test when the PAT tester’s bond lead is attached to the only exposed metalwork visible; the sleeve ...
SNC1D7: Static and Current Electricity Test
SNC1D7: Static and Current Electricity Test

... a) Electrons have a choice of paths in a series circuit, and no path choice in a parallel circuit b) Electrons have a choice of paths in a parallel circuit, and no path choice in a series circuit c) Series connections have lower resistances than parallel connections d) Series connections have higher ...
THE HIGH RESISTANCE GROUNDED POWER SYSTEM
THE HIGH RESISTANCE GROUNDED POWER SYSTEM

... A common practice is to ground all types of generators through some form of external impedance. The purpose of this grounding is to limit the mechanical stresses and fault damage in the machine, to limit transient voltages during fault, and to provide a means for detecting ground faults within the m ...
Unit-8Lecture 52 TESTING OF CABLES Cables are very important
Unit-8Lecture 52 TESTING OF CABLES Cables are very important

... Transformers are very important and costly apparatus in power systems. Great care has to be exercised to see that the transformers are not damaged due to transient overvoltages of either lightning or power frequency. Hence, overvoltage tests become very important in the testing of transformers. Here ...
BASIC ELECTRICAL TECHNOLOGY (ELE 101/102)
BASIC ELECTRICAL TECHNOLOGY (ELE 101/102)

“bonding” and “grounding”
“bonding” and “grounding”

... It is extremely important that all conductive surfaces and equipment enclosures associated with any power distribution system be effective bonded together via a low impedance path. Without a very low impedance path for ground fault current to flow in a relatively controlled path potential rises or s ...
Conductors And Insulators Activity
Conductors And Insulators Activity

Generators 2 - I Will Prepare
Generators 2 - I Will Prepare

Final Review CIRCUITS:
Final Review CIRCUITS:

analog - IHS.com
analog - IHS.com

... Figure 5. Basic Grounding Practice ...
chapter 8 - Power Quality
chapter 8 - Power Quality

... The solution to transients problems is the installation of surge protection equipment. While some utilities install surge suppression equipment on their distribution lines it is still necessary for the customer to install equipment in their home or business. Wiring solutions include using special ci ...
High Voltage High-Resistance Pulsing Ground Systems
High Voltage High-Resistance Pulsing Ground Systems

... applied on wye-connected sources when the neutral point is not conveniently accessible from the service entrance location. This method is shown in the illustration to the left. One delta high-resistance grounding would ground the 5 kV system. ...
Sample Problem Topic: Thévenin and Norton
Sample Problem Topic: Thévenin and Norton

... Topic: Thévenin and Norton equivalents (Maximum Power Delivery) Statement of Problem: Given the circuit shown in the figure below ...
DEPARTMENT OF ELECTRICAL ENGINEERING EA6210: SWITCHGEAR AND PROTECTION DIT UNIVERSITY, DEHRA DUN
DEPARTMENT OF ELECTRICAL ENGINEERING EA6210: SWITCHGEAR AND PROTECTION DIT UNIVERSITY, DEHRA DUN

Millennia Media
Millennia Media

... 3. Earth/Audio Ground Jumper — A barrier terminal which ties earth ground to audio ground. If ground "hum" loops are experienced when using the NSEQ-4, removing this jumper may help. Using this jumper, the integrity of the chassis/earth ground connection is never compromised. Do not defeat the earth ...
Physics 536 - Assignment #7
Physics 536 - Assignment #7

... large enough that it does not change the shape of the output waveform. (a) Show that the small signal gain of this circuit is G = +5. (b) What is the output impedance of this circuit? (c) If the circuit were connected to a resistive load, RL = 5 kΩ, what would be the amplitude of the voltage, vL , m ...
AI-LCD65-0x-x_530217 - UTC Aerospace Systems
AI-LCD65-0x-x_530217 - UTC Aerospace Systems

... Ensure that all power and ground are 22 AWG, minimum. Power ground wires must be grounded within twelve inches of the unit. Protect power wires with circuit breakers or fuses located close to the electrical power source bus. Ensure that power and ground are applied only where required. Video input s ...
What is a power surge?
What is a power surge?

... Power surges can disrupt, degrade or destroy any electrical or electronic equipment connected to the AC Power system. Particularly vulnerable are appliances, home theater systems and home office equipment ...
The Evaluation of Steel Conduit and EMT as Equipment
The Evaluation of Steel Conduit and EMT as Equipment

... equipment and wiring and other electrically conductive material likely to become energized shall be installed in a manner that creates a low-impedance circuit facilitating the operation of the overcurrent device or ground detector for high-impedance grounded systems.” • “It shall be capable of safel ...
< 1 ... 539 540 541 542 543 544 545 546 547 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report