• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TRIODE ELECTRONICS JCM800 2203 100W LAYOUT
TRIODE ELECTRONICS JCM800 2203 100W LAYOUT

... Touch the positive lead to Pin 3 (plate) of one of the EL34 power tube sockets. This is your Plate Voltage. Write it down. *BE VERY CAREFULL WITH THIS STEP (HIGH VOLTAGES PRESENT)* 3) EL34's are 25 watts maximum dissipation and you want to set the bias to 70% max dissipation. (70% = 17.5 watts) Divi ...
6.0 Electrical Installations - Department of Electrical Engineering
6.0 Electrical Installations - Department of Electrical Engineering

... wire) type and supplied at 230 V line to neutral. Basic arrangement of the connections from the supply authority’s distribution pole is shown. This shows the installation diagram from the service cable of the supply authority, which is usually supplied overhead from the distribution pole. This comes ...
Plant Electrician Job Description - Center of Excellence for Clean
Plant Electrician Job Description - Center of Excellence for Clean

... Perform skilled journey-level work in the construction, maintenance and repair of electrical and electronic equipment, apparatus and fixtures used at power generation plants. RESPONSIBILIES/ ACCOUTABILITIES: May be responsible to perform a combination of the following duties based upon job assignmen ...
Oscilloscope and High Voltage Probe Facilitage Motor
Oscilloscope and High Voltage Probe Facilitage Motor

... section in a Robicon cell. In designing the cells, and the system as a whole, care must be taken to minimize the inductance of the power buses connected to the cell output. Excessive inductance can cause “kickback” voltages to occur when an IGBT is rapidly switched off. Even though the effective DC ...
Electrical Safety * NFPA Requirements
Electrical Safety * NFPA Requirements

... - Leakage tests shall be performed in the ‘ON’ and ‘OFF’ positions to simulate realworld patient-care situations - Leakage current shall not exceed 10mA through the grounding conductor of permanently-wired equipment, while grounds are lifted. - No annual requirement for performing electrical safety ...
Power Quality Counts
Power Quality Counts

... Current delivered from power utilities is a clean, linear voltage sinewave that has a relatively constant amplitude and frequency. Modern electronic motors and equipment are non-linear devices, which break up the linear sinewave and create a 3rd harmonic. These harmonics cause heat that can overheat ...
Overcurrents
Overcurrents

... Electrical distribution systems are often quite complicated. They cannot be absolutely fail-safe. Circuits are subject to destructive overcurrents. Harsh environments, general deterioration, accidental damage or damage from natural causes, excessive expansion or overloading of the electrical distrib ...
Unit 43: Current, voltage and resistance Dr. Basil Hamed Technical
Unit 43: Current, voltage and resistance Dr. Basil Hamed Technical

... Dr. Basil Hamed IUG ...
BalPreamp
BalPreamp

CODEC Printed Circuit Board Layout Considerations
CODEC Printed Circuit Board Layout Considerations

... Because of the wide dynamic range and the typical environment in which the CODEC is used, PC board layout is very important. It is important with any mixed-signal device but CODECs are often in very “noisy” environments with many digital, and radio frequency (RF) signals, running about the board. So ...
Common Impedance Coupling
Common Impedance Coupling

... At the ground point of subsystem 1, V1 has the signals of subsystem 2, I2 coupled to it by virtue of the nonzero impedance ZG1 shared by both signals. At the ground point for subsystem 2, V2 has the signals of subsystem 1, I1 imposed on it through ZG1. This phenomenon is referred to as common-impeda ...
section 16450
section 16450

2A. Two similar inductive coils with negligible resistance are wound
2A. Two similar inductive coils with negligible resistance are wound

... 5B.  A 30KVA, 2400/120 V, 50Hz transformer has high voltage winding resistance of 4.5 Ω and leakage  reactance  of  10  Ω.  The  corresponding  values  on  low  voltage  winding  are  0.01  Ω  and  0.025  Ω.    The iron losses are 1.5 KW. Calculate   (a) equivalent impedance referred to high voltage ...
Power Quality Counts
Power Quality Counts

... from absorbing the heat over time as well as from pollution (dirt, chemicals, etc.). The megohmmeter function in the DM-III allows technicians to test the insulation integrity of wire, cables, transformers and electric motors with selectable test voltages up to 1000V. Finally, if the power quality a ...
LA125-P - RGB Automatyka
LA125-P - RGB Automatyka

Definitions
Definitions

... The statement which defines the Company's standard electric services, the rates for such services, and the rules and regulations governing the supply of such electric services, on file with, and accepted by, the State where electric service is offered. 2.37 THREE PHASE CIRCUIT A combination of circu ...
Tens kilowatts power supply based on half
Tens kilowatts power supply based on half

... both the turning-on and turningoff of the switches at the zero current condition. Half-bridge inverter seems to be preferable due to the only two switch equipment, it lowers both the inverter costs and the switching loses. Half-bridge inverter operation in the proposed regime does not need the free- ...
Electricity Answers
Electricity Answers

... Use your formula to show that the resistance between the terminals of a low-resistance component is hardly changed when a high-resistance voltmeter is connected in parallel with it. If Rv >>Rlow then 1/Rv >> 1/Rlow and RT  Rlow ...
- Discuss the measurement of power in circuits
- Discuss the measurement of power in circuits

... dryers, have special outlets for higher voltages). What typical currents do most household appliances operate at? Current varies but not TOO high - more than A total will trip most circuit breakers. Some devices, like cell phone chargers and electronics (especially computers) can be damaged by more ...
Chapter 8: Data Communication Fundamentals
Chapter 8: Data Communication Fundamentals

... Muschenbrock, in Leyden (Netherlands), discovered the Leyden jar in 1745  Leiden jar, is a device that "stores" static electricity between two electrodes on the inside and outside of a jar.  The invention was named for this city  It was the original form of the capacitor  The Leyden jar was used ...
Voltage in Electrical Systems
Voltage in Electrical Systems

...  Control element – a switch that turns the current in the system on or off.  Electrical circuit – closed path for current flow created by connecting voltage sources, conductors, control elements, and loads. ...
Test Procedure for the NCP2823AGEVB Evaluation Board
Test Procedure for the NCP2823AGEVB Evaluation Board

... bypass J11 terminal. Like this the device can be evaluate under powering conditions very similar to that of battery power supplies. These tests are provided in order to guarantee a good assembly of the NCP2823 on its dedicated board; it does not consist in parametric test which is already done at ch ...
30 mins Mains electricity exam Qs C with answers
30 mins Mains electricity exam Qs C with answers

... there is no electrical pathway between inner and outer insulation accept no connection between inner and outer part do not credit two layers of insulation ...
Electrophoresis Safety
Electrophoresis Safety

... • When locating, or working around or near an electrophoresis unit, avoid unintentional grounding points and conductors (e.g., sinks and other water sources, metal plates, aluminum foil, jewelry, pipes, or other metal equipment). If a darkened box is needed for light sensitive work, a black photogra ...
Unit 3 Day 5: EMF & Terminal Voltage, & DC Resistor Circuits
Unit 3 Day 5: EMF & Terminal Voltage, & DC Resistor Circuits

... • A device that supplies electrical energy to a circuit is called the source of what is referred to as the Electromotive Force or EMF ( ) • EMF is a misnomer because the battery does not deliver a force in Newtons • The potential difference ΔV=Vab , is measured across the terminals of a battery ...
< 1 ... 541 542 543 544 545 546 547 548 549 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.