• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
BasisBlock MC1 - IPU Industrial Power
BasisBlock MC1 - IPU Industrial Power

... The switching panel is of a bolted construction using high-quality galvanised sheet steel with a thickness of 2 mm. An extraordinarily torsionally rigid, self-supporting sheet steel structure is achieved by the appropriate folding of the edges. The front uses pressure resistant doors whic ...
Second Year Electronic Laboratory Electronics Construction
Second Year Electronic Laboratory Electronics Construction

... Figure 2 - supply and ground noise issues The most common and important source of problems due to layout is this causes the circuit supplies to be noisy, and this couples noise into the circuit. Feedback paths between different parts of the circuit can easily cause unintended positive feedback (and ...
Series And Parallel Circuits Vocabulary Teacher Guide
Series And Parallel Circuits Vocabulary Teacher Guide

Figure 6. Simple circuit to demonstrate triac operation
Figure 6. Simple circuit to demonstrate triac operation

little-engineers-09
little-engineers-09

... • Current tells us the amount of charge flowing through something (similar to gallons per minute). • Current must have a path through which to flow. • Wires provide a path for current flow (and offer no no resistance to the flow). ...
Chapter 4: Electronic and Signals
Chapter 4: Electronic and Signals

... cable originates from signals on other wires in the cable, this is known as crosstalk. Solution: quality cables and termination. 2. Thermal noise, due to the random motion of electrons, is unavoidable but usually relatively small compared to our signals. 3. AC Power/Reference Ground Noise: bad groun ...
Chapter 20 - Teacher Pages
Chapter 20 - Teacher Pages

... • A wire that carries more current than it is designed to carry will become hot – leading to a fire. – In order to prevent circuits from overheating, devices called fuses and circuit breakers are added to circuits. – A fuse contains a thin strip of metal that will melt if too much current flows thr ...
User`s Manual Three Output DC Regulated Power Supplies Models
User`s Manual Three Output DC Regulated Power Supplies Models

Static electricity
Static electricity

Question 1 - cloudfront.net
Question 1 - cloudfront.net

Current Transducer LF 305
Current Transducer LF 305

... This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. ...
Electrical power is usually taken for granted and once a piece of
Electrical power is usually taken for granted and once a piece of

ad-series-mains-power-supplies
ad-series-mains-power-supplies

... The AD Series units may be used to supply mobile radios and other appliances from AC mains used in offices, portable site cabins, communication cabins, telephone exchanges, remote antennae sites, ships, oil rigs etc. The units will accept either European 230Vac or US 115Vac inputs and are available ...
Solid – State VARIAC ® Replacement - hot
Solid – State VARIAC ® Replacement - hot

... shown in Figure 3. The novelty of this circuit is that is will work with two winding (i.e. center tapped) primary transformers. A “pole-pig” residential distribution transformer is of the correct primary configuration to work. The advantages of this circuit are: 1. AC wave is rectified prior to pass ...
Kirchhoff`s Laws and Superposition
Kirchhoff`s Laws and Superposition

Distributed Generation at Clemson University
Distributed Generation at Clemson University

... • If DG is solidly grounded, voltage rise of healthy phases for single-phase faults can be less severe, but single-phase currents can increase drastically. • If DG is grounded through impedance, single-phase fault currents would get less severe, but voltage rise of healthy phases can get worse. • Fo ...
Technology Selection - Sunrator Technologies LLP
Technology Selection - Sunrator Technologies LLP

... • Extensive testing for withstanding the load conditions at the site. • Allow field adjustments that may reduce installation time and compensate for inaccuracies in placement of foundations. • Thermal expansion using expansion joints where necessary in long sections for modules not getting unduly st ...
BEAT THE VOLTAGE DROP
BEAT THE VOLTAGE DROP

Curriculum Vitae - Point to Point Education
Curriculum Vitae - Point to Point Education

... • “Firefly Algorithm based Power Economic Dispatch of generators using valve point effects and multiple fuel options”, IJEIT Journal, ISSN: 2277-3754, July 2013. • “An improved single phase Transformerless Inverter Topology for cost effective PV systems”, International Journal of Modern Engineering ...
physics 202 - La Salle University
physics 202 - La Salle University

... Such a circuit could be used to switch to back-up power. Unfortunately there may be a time delay in such a circuit, so something more sophisticated is needed. ...
Domain 4: Waves, Electricity, and Magnetism
Domain 4: Waves, Electricity, and Magnetism

circuit
circuit

... that the power source is PRODUCING. This is why LIGHTS that are wired in PARALLEL are BRIGHTER than those wired in SERIES ...
Ch 5 Homework - ECM
Ch 5 Homework - ECM

... 25. A(n) ____ is a machine, device, or system that changes DC voltage into AC voltage and can be designed to produce variable frequency. ...
42V systems allow better power management
42V systems allow better power management

... that could be opened during replacement of fuses, batteries and other components. Mechanical design features must ensure that electrical terminals are correctly seated and locked. Therefore, increased use of clips, clamps and shields may be required. Implementation of 42V systems will affect the des ...
Designing to Protect MAX2140`s Internal ESD
Designing to Protect MAX2140`s Internal ESD

... result, the MAX2140's electrical ground rises above the electrical ground of the antenna module. This difference creates for a short time a forward voltage on the MAX2140's internal ESD diode, which is connected from the IC's ground to pin 16. That forward voltage spike can exceed the device's absol ...
< 1 ... 518 519 520 521 522 523 524 525 526 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.