• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electricity and Electromagnetism
Electricity and Electromagnetism

Ground fault testing
Ground fault testing

... Both mesh and Faraday enclosure (not shown) are tightly connected to Analog ground as shown above. Thus, the Micromegas pulse is seen as a current source which couples directly to the resistive strip and then capacitively to the readout strip, losing about 10%-15% of its charge in the process. The ...
Procedure - Rose
Procedure - Rose

... Wire the circuit of figure 1. Note that the circuit has a signal ground and a power ground. To keep high currents from flowing through the signal ground, we make the grounds separate, and then connect them at a single point. This point is shown on the circuit drawing. Also note that we are wiring up ...
series circuit - Madison County Schools
series circuit - Madison County Schools

... current draw on the source goes up with each new branch. If the source cannot supply the current that is demanded by the multiple resistors of the circuit, the voltage will (must!) decrease. This could be bad, as some devices, notably motors, do not like to run at low voltage and can actually be dam ...
10EE751 HVDC TRANSMISSION
10EE751 HVDC TRANSMISSION

... The voltage control in AC lines is complicated by line charging and inductive voltage drops. The voltage profile in a AC line relatively flat only for fixed level of power transfer corresponding to surge impedance loading (SIL) or normal loading. The Voltage profile varies with the line loading. For ...
current transformers
current transformers

... A current transformer produces a output signal directly proportional to the magnitude of the current flowing in the conductor around which it is put. The output signal from the current transformer is sent to the meter and the current flow in the primary circuit calculated. A current transformer is r ...
Lecture 9
Lecture 9

Instructor : Dr - eem.anadolu.edu.tr
Instructor : Dr - eem.anadolu.edu.tr

... since HV side has a lower rated current than low voltage (LV) side. This prevents too high currents from flowing through instrumentations. Similarly short circuit test is performed from the LV side to avoid high voltages across instrumentations ...
Input Sources
Input Sources

... For Axiomatic products, refer to technical data for an internal reference voltage. For potentiometer control outside that range, connect the potentiometer to an external voltage source. ...
BMPI Series
BMPI Series

... protection and power quality for any type of load, especially industrial applications, manufacturing and petrochemical processes, electrical distribution and power plants. BMPI is an On-line double conversion UPS (VFI SS 111 - IEC EN 62040-3) with input and inverter transformers. ...
All About Electric Fields
All About Electric Fields

... Step 4. Outside, attach the alligator clip (at the end of the long black ground wire) to the metal shank of the ground rod (screw driver) in the soil. Make sure that the alligator clip is well connected to the metal shank part of the screwdriver (ground rod). It’s a good idea to wrap some tape aroun ...
Preventing Electrostatic Discharge (ESD) Damage - Alpha
Preventing Electrostatic Discharge (ESD) Damage - Alpha

... the person creating the damage. This is because static discharges below 3,000 or 4,000 volts are “invisible” – people don’t feel them at all. On the other hand, in dry air, a person walking across a carpet can build up a static charge in the 35,000 to 40,000 volt range. When this type of charge is p ...
1 - UniMAP Portal
1 - UniMAP Portal

... 8. The armature winding of a dc motor has 320 conductors, only 70 % of which lie directly under the poles, where the flux density B = 1.1 T. The armature diameter is 26 cm and its length is 18 cm. The conductor current is 12 A. Determine: a) The total force created by the conductor. b) The torque de ...
Probe Selection
Probe Selection

1. General Description General Features
1. General Description General Features

... The LP133X7 is a Color Active Matrix Liquid Crystal Display with an integral Cold Cathode Fluorescent Lamp(CCFL) back light system. The matrix employs a-Si Thin Film Transistor as the active element. It is a transmissive type display operating in the normally white mode. This TFT-LCD has a 13.3 inch ...
Multi-functional Packaged Antennas for Next
Multi-functional Packaged Antennas for Next

... Only then the voltage appears across the load. In reverse bias, the diode blocks the voltage, i.e. acts as an open circuit. Thus the voltage across the load becomes zero. For ideal diodes, the voltage drop in forward bias is zero. For real diodes the voltage drop is usually few tenths of a volt. The ...
Technical Brief - DC Circuit Protection
Technical Brief - DC Circuit Protection

TR41.9.2-03-05-016-R1-TransverseBalAltDraft
TR41.9.2-03-05-016-R1-TransverseBalAltDraft

... (transverse balance of 30dB). For the quantified range for pass fail criteria (35dB minimum), a worst case error of 0.136dB at 30dB is completely acceptable. Of course, as the quality of the EUT improves, the error reduces proportionately, so the error at 35dB is truly negligible. ...
ET101 - Mohawk Valley Community College
ET101 - Mohawk Valley Community College

Circuits Notes - BAschools.org
Circuits Notes - BAschools.org

... A switch is a part of a circuit designed to break the closed path of charge. When a switch is open, it produces a gap in the circuit so that the charge cannot flow. A switch that is on closes the circuit and allows the charges to flow. A switch that is off opens the circuit and stops the current. ...
L551A_M5500EX (Page 1)
L551A_M5500EX (Page 1)

... each other as well as all other outlet banks. ...
AdvancedTCA Hot Swap Controller Monitors Power Distribution Design Note 397 Mitchell Lee
AdvancedTCA Hot Swap Controller Monitors Power Distribution Design Note 397 Mitchell Lee

... voltage dropout. An energy of 1J is needed to sustain a 200W load during this interval. The accepted method of energy storage to satisfy the 1J requirement is a bulk reservoir capacitor which is charged through resistors. This technique dictates the use of bulky high voltage storage capacitors, such ...
static voltage regulator.cdr
static voltage regulator.cdr

FRAnalyzer Brochure
FRAnalyzer Brochure

... innovative testing and diagnostic solutions. The application of OMICRON products allows users to assess the condition of the primary and secondary equipment on their systems with complete confidence. Services offered in the area of consulting, commissioning, testing, diagnosis and training make the ...
V-Watch Personal Voltage Detectors
V-Watch Personal Voltage Detectors

... Visit our website to view the V-Watch Personal Voltage Detector Video and get more information – HDElectricCompany.com. HD Electric Company For over eighty years, HD Electric Company, a Textron Company, has provided products serving the diverse needs of the electrical power industry and its related ...
< 1 ... 497 498 499 500 501 502 503 504 505 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report