• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Document
Document

... Three linear equations and three unknown ...
静電気試験規格最新動向 ISO 10605 Ed.2 - Southeastern Michigan
静電気試験規格最新動向 ISO 10605 Ed.2 - Southeastern Michigan

... accessed only from the inside of the vehicle and resistance of 330 Ω or 2 kΩ. Choose a capacitance of 150 pF for points that can easily be touched only from the outside of the vehicle and resistance of 330 Ω or 2 kΩ. The test voltages (in accordance with Annex C) shall be increased, using at least t ...
www.rustrade.cz
www.rustrade.cz

... cables of high reliability and durability. Its work is based on output of products: - Aluminum clad steel wire - Ground wires of high corrosion stability - Phase wires of high durability - High-voltage, high heat-resistant wires - Fire-resistant, flame-safe power cables - Self-supporting insulated w ...
FlexMod™ LVD Low Voltage Disconnect
FlexMod™ LVD Low Voltage Disconnect

... 1. Connect pin 4 (BATT+) to an appropriately sized fuse. Connect the fuse to the positive terminal of the battery. 2. Connect pin 3 (LOAD+) to the positive side of the load. 3. Connect pin 2 (GND) to ground. 4. To ensure proper environmental sealing, all unused connector pins must be sealed with bla ...
ED EX 702QUES - St. Aloysius Institute of Technology, Jabalpur
ED EX 702QUES - St. Aloysius Institute of Technology, Jabalpur

... Answer:Bulbs [devices] for AC are designed to operate such that it offers high impedance to AC supply. Normally they have low resistance. When DC supply is applied, due to low resistance, the current through lamp would be so high that it may damage the bulb element. 16. whats the one main difference ...
ﺟﺎﻣﻌﺔ ﺑﻧﮭﺎ ﮐﻟﯾﺔ اﻟﮭﻧدﺳﺔ ﺑﺑﻧﮭﺎ ﻗﺳم اﻟﮭﻧدﺳﺔ اﻟﮐﮭرﺑﯾ
ﺟﺎﻣﻌﺔ ﺑﻧﮭﺎ ﮐﻟﯾﺔ اﻟﮭﻧدﺳﺔ ﺑﺑﻧﮭﺎ ﻗﺳم اﻟﮭﻧدﺳﺔ اﻟﮐﮭرﺑﯾ

... A GTO can operate safely in the “reverse avalanche” region for a short time provided the gate .cathode junction is reverse biased The switching delay times and energy loss of a GTO can be reduced by increasing the gate • .current magnitude and its rate of rise The maximum turn off anode current ...
FJB102 High Voltage Power Darlington Transistor F JB
FJB102 High Voltage Power Darlington Transistor F JB

... SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: ...
Susceptibility of Integrated Circuits to RFI: Analysis of PWM
Susceptibility of Integrated Circuits to RFI: Analysis of PWM

SWITCHGEAR PROTECTION
SWITCHGEAR PROTECTION

... A contactor is a device for opening or closing a circuit under load conditions by pushbutton control. The operation is usually electromagnetic, but it may be electro pneumatic. The contactor is ideal for remote and automatic control and is made use of in many appliances and, in particular, in many t ...
P85271
P85271

... CAUTION: Check the installation instructions of the manufacturers of other equipment used in the system for any guidelines or restrictions on wiring and/or locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for exampl ...
Download
Download

... Hydrogen fuel is a safe and ecofriendly type of fuel used in automobiles. Future generation are waiting to welcome the invention of hydrogen powered vehicle. ...
UNIT SUBSTATIONS - Federal Pacific
UNIT SUBSTATIONS - Federal Pacific

X5000A3
X5000A3

Halogen Lamp Modeling For Low Voltage Power - HAL
Halogen Lamp Modeling For Low Voltage Power - HAL

... lamps driven directly in LV power systems - low voltage halogen lamps (HLs); extra low voltage halogen lamps (ELHs) driven by a LV/extra low voltage (ELV) conversion device such as TT or ET. In literature, ATP-EMTP models of TTs [3], [4], [5], [6] for different application such as current transforme ...
Full Text - ISSN: 1545
Full Text - ISSN: 1545

... The circuit shown in Figure 2 applies phaseshifting zero voltage zero current full-bridge inverter. It can utilize soft switch technique to make the transformer’s two bridge-arm switches workable below zero voltage or zero current. Rectifier VC outputs 540V direct current. IGBT module, capability an ...
UNIT 1 Microelectronics and Electronic Circuits
UNIT 1 Microelectronics and Electronic Circuits

... concentration of electrons in the channel provides a path by which the electrons can move easily from the source to the drain. When that happens, the MOSFET is ‘on’ (or ‘closed’) and current can flow from the source to the drain freely.” “In summary, a MOSFET in a microchip is turned on by applying ...
The Research on Neutral Grounding Scheme of Fengxian 35kV and
The Research on Neutral Grounding Scheme of Fengxian 35kV and

... tripping of the circuit breaker and reduce supply continuity, thereby, it reduce supply reliability. 2) Neutral point ungrounded system: the current of single-phase grounding fault is very small in ungrounded system. It can operate with fault for some time in order to find the fault line, thus the r ...
Earthing - WordPress.com
Earthing - WordPress.com

... system at a known value so as to prevent over current or excessive voltage on the appliances or equipment . ...
Sep 2003 Low Voltage Amplifiers Give Choice of Accuracy or Speed
Sep 2003 Low Voltage Amplifiers Give Choice of Accuracy or Speed

... which is very useful on limited supplies. Put another way, in order to get 100kΩ sensitivity and still handle a 1mA signal level without resorting to gain reduction, the circuit would need a 100V negative voltage supply. The operation of the circuit is quite simple. At low photodiode currents (below ...
SNUBBERS
SNUBBERS

... device. A spark is likely to be generated (arcing), which can cause electromagnetic interference in other circuits. The snubber prevents this undesired voltage by conducting transient current around the device. ...
Power supply CP-D 12/2.1
Power supply CP-D 12/2.1

... Connect the input terminals L and N. The installation must be executed acc. to EN 60950, provide a suitable disconnecting device (e. g. line protection switch) in the supply line. The input side is protected by an internal input fuse. Rate the lines for the maximum output current or provide a separa ...
Thevenin Theorem
Thevenin Theorem

... i). Use this method when all the sources are independent ones. ii). Deactivate all the independent sources (by replacing a voltage source by short circuit, and a current source by open circuit). iii). Find the equivalent resistance seen from the terminals --> Rth (b) Short Current Method i). Use thi ...
Document
Document

... Some welding machines are capable of producing both AC and DC Welding current. Welding cables: ...
Pulse Width Modulation Amplifiers
Pulse Width Modulation Amplifiers

... supplied at the time of order acknowledgment, including those pertaining to warranty, indemnification, and limitation of liability. No responsibility is assumed by Cirrus for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infr ...
Resident Physics Lectures
Resident Physics Lectures

... Fields • Whenever an electric current flows through a conductor, a magnetic field surrounds the conductor • Magnetic field can be concentrated by coiling conductor Magnetic Field N ...
< 1 ... 333 334 335 336 337 338 339 340 341 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report