• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
FX Series - Glassman High Voltage
FX Series - Glassman High Voltage

... After this period the supply will automatically return to the programmed kV value with the rise time constant indicated. If the load fault still exists, the above cycle will repeat. Standard on 8 - 60 kV models; optional on 1- 6 kV models. Remote Controls: A three position terminal block and a 15 Pi ...
15C02MH 数据资料DataSheet下载
15C02MH 数据资料DataSheet下载

... system, safety equipment etc.) that shall require extremely high level of reliability and can directly threaten human lives in case of failure or malfunction of the product or may cause harm to human bodies, nor shall they grant any guarantee thereof. If you should intend to use our products for new ...
Beyond the ATE printout..
Beyond the ATE printout..

... • Present a new set of challenges • The short (or bus fault) has to be located in two dimensions • So what how can a VPS equipped Toneohm help? ...
SECTION 264313 SURGE PROTECTIVE DEVICES 03/03/14
SECTION 264313 SURGE PROTECTIVE DEVICES 03/03/14

... Fuses, rated at 200-kA interrupting capacity. Provide fusing for each suppression path. ...
Evaluates:  MAX8586 MAX8586 Evaluation Kit General Description Features
Evaluates: MAX8586 MAX8586 Evaluation Kit General Description Features

Force Sensitive Resistor (FSR) Sensor Lab
Force Sensitive Resistor (FSR) Sensor Lab

... data is plotted on a log/log format. For Further details see [1]. ...
Grounding Design for
Grounding Design for

... Among the experimental architectural complex, all of the grounding-grids in each individual building shall be connected at each grounding terminal by bus bar to form the general grounding-grid. The general grounding-grid of HT-7U consists of nearly all the experimental buildings in site except HV po ...
International Technology Roadmap for Semiconductors
International Technology Roadmap for Semiconductors

... An International Technology Roadmap for Semiconductors ...
Magnetically induced voltages and currents in Ethernet cables due
Magnetically induced voltages and currents in Ethernet cables due

... Figure 13 shows the circuits and operation of a single chamber, 3-electrode GDT and two 2-electrode GDTs. It is assumed that a longitudinal surge on the R and T conductors causes the spark-over of the GDT section (GDTT and GDT1 respectively) connected to the R conductor. The waveform on the R conduc ...
C5EA02 How does the resettable fuse work.cdr
C5EA02 How does the resettable fuse work.cdr

... HOW DOES THE RESETTABLE FUSE WORK HOW DOES THE RESETTABLE FUSE WORK Figure 3 - PTC Curve For Fuzetec TM R esettable Fus e ...
October, 1987 P/N 21-6100 DUAL SHOWMAN TOP AMPLIFIER P/N
October, 1987 P/N 21-6100 DUAL SHOWMAN TOP AMPLIFIER P/N

... The vibrato assembly consists of a photo-cell and a neon lamp held together by a piece of 0.025 inch thick black heat shrink tubing. One side of the photo-cell or LDR, goes to a control potentiometer and the other side goes to ground. One side of the NE-2 neon lamp goes to a 100K resistor, and the o ...
Lecture 19
Lecture 19

BC107B
BC107B

... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
CP Physics Name Magnetism HW #5 Why is electrical energy
CP Physics Name Magnetism HW #5 Why is electrical energy

... CP Physics Name __________________ Magnetism HW #5 1) Why is electrical energy transmitted at high voltages and low current? ...
Reflection Coefficient
Reflection Coefficient

... • Based on fundamental principles, we have determined that the voltage and current that we would measure on a transmission line is the superposition of two sets of voltages and currents, corresponding to power flowing in both directions. • We have defined the concept of normalized impedance. • We ha ...
Sample Curriculum
Sample Curriculum

... All  Components  are  installed  permanently  in  the   1  –  Lab  Manual   panel  inside  suitcase.  When  the  lid  is  removed,   the  case  can  either  stand  or  lie  on  a  table  for  use   by  students.  Color  code  char ...
High Efficiency Motor Protection Industry White Paper
High Efficiency Motor Protection Industry White Paper

... The asymmetrical offset is dependent mainly upon at which point on the voltage wave the circuit is energized. If the circuit is energized at a voltage maximum, there is no asymmetrical offset and the inrush current is essentially the LRC for that current phase. However, if the circuit is energized w ...
estimation of voltage ratio, vector - e
estimation of voltage ratio, vector - e

... No-load losses (also referred to as core losses and iron losses) are a very small part of the power rating of the transformer, usually less than 1%. Since these losses are essentially constant for the each transformer (do not vary with load), they generally represent a sizable operating expense espe ...
Electrical test equipment for use by electricians GS38
Electrical test equipment for use by electricians GS38

... adequately insulated and arranged to be suitable for use with the test leads, as a safe alternative to the use of test probes. 24 It is important that a multifunction or multirange meter is set to the correct function and/or range before the connections are made. Where there is doubt about the valu ...
electrical safety guideline - University of Northern Colorado
electrical safety guideline - University of Northern Colorado

... than 300 Volts (for terminal to ground operation). Low voltage, high current AC or DC power supplies are also considered to be high voltage. Hazardous Energy Sources: This term applies to stored or residual energy such as that in capacitors, springs, elevated machine members, rotating flywheels, hyd ...
IS31LT3380 MR16 Lighting Evaluation Board Guide Description
IS31LT3380 MR16 Lighting Evaluation Board Guide Description

... voltage source higher than the LED voltage. The chip operates from an input voltage between 8.5V and 40V and provides an output current up to 1.2A. The IS31LT3380 includes a high-side output current sensing circuit, which uses an external resistor to set the nominal average output current. The IS31L ...
Eaton Innovative TechnologyT XT50/100 surge protective device
Eaton Innovative TechnologyT XT50/100 surge protective device

... With all phase voltages present, if an LED turns OFF, the SPD has disconnected itself from that phase of the electrical system because one of its thermally protected MOVs has failed. If a thermally protected MOV fails, power will be maintained to the load; however, the load is now unprotected. The X ...
MAX9993 EV kit
MAX9993 EV kit

... Testing the Mixer Adjust the center and span of the spectrum analyzer to observe the IF output tone at 200MHz. The level should be about +0.5dBm (8.5dB conversion gain, 3dB pad loss). There will also be a tone at 199MHz, which is due to the LO signal applied to LO2. The amount of suppression between ...
ECE 310 - University of Illinois at Urbana–Champaign
ECE 310 - University of Illinois at Urbana–Champaign

... open circuit test: rated voltage is applied to primary with secondary open; measure the primary current and losses (the test may also be done applying the voltage to the secondary, calculating the values, then referring the values back to the primary side). short circuit test: with secondary shorted ...
Series and Parallel Circuits - Chabot College Physics Lab
Series and Parallel Circuits - Chabot College Physics Lab

< 1 ... 332 333 334 335 336 337 338 339 340 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026