• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
UcD32MP UcD34MP UcD36MP
UcD32MP UcD34MP UcD36MP

... The UcD3xMP is a high efficiency Safety Class 2 multichannel mains powered UcD module. Key features are high efficiency over the entire load range, extremely small form factor, low weight and very low radiated and conducted EMI. The UcD3xMP also features an advanced over current protection which in ...
Short Catalog 12 Halaman.cdr
Short Catalog 12 Halaman.cdr

... Take in account the energetic information to choose the tracer which can become an ascending tracer. Maintain the propagation of the tracer by discharge of the power device. Source of energy autonomous and clean Solar (2) or wind (1) energy for the "power device" Atmospheric electrical field for the ...
Constant Voltage Sinusoidal Transformers Operating and Service
Constant Voltage Sinusoidal Transformers Operating and Service

... the unit when it is not in use. While all CVS transformers are designed for continuous duty, they draw appreciable current regardless of output loading. The outputs of all Sola/Hevi-Duty standard CVS transformers are isolated from the input lines. Voltage generated by internal leakage currents will ...
Chapter_3_Lecture_PowerPoint
Chapter_3_Lecture_PowerPoint

... very useful in the computation of equivalent circuits, permitting, in some circumstances, replacement of current sources with voltage sources and vice versa. The Norton and Thévenin theorems state that any oneport network can be represented by a voltage source in series with a resistance, or by a cu ...
Case Study - Consulting-Specifying Engineer Magazine, September, 2010
Case Study - Consulting-Specifying Engineer Magazine, September, 2010

... hen the University of Wyoming Cowboys meet rival teams on Jonah Field at War Memorial Stadium in Laramie, it is important to keep the lights on for tv cameras airing the big game. More importantly, in the case of an emergency, the more than 30,500 attendees need to be able to exit the stadium safely ...
Evaluates:  MAX5069A MAX5069A Evaluation Kit General Description Features
Evaluates: MAX5069A MAX5069A Evaluation Kit General Description Features

Product Profile No. 3181
Product Profile No. 3181

... signaling of all protection modules make status monitoring easy and accurate in any monitoring scheme. ...
PR570TRN
PR570TRN

... 1 Do not use an isolation transformer for this test. Plug the completely reassembled unit directly into the ac outlet. 2 Connect a 1.5K, 10W resistor paralleled by an .015uF capacitor between each exposed metal cabinet part and a good earth ground such as a water pipe, as shown above. 3 Use an ac vo ...
to notes15
to notes15

... at the meter. Maintaining acceptable service voltage is the distribution company’s responsibility.  Utilization voltage: The voltage at the line terminals of utilization equipment. This voltage is the facility’s responsibility. Equipment manufacturers should design equipment which operates satisfac ...
4. Electrical Work General
4. Electrical Work General

... Ensure any electrical work performed by Council employees or contractors, that the person performing the task is a qualified Licensed Electrician. Trainees or apprentices must be appropriately trained and supervised at all times. Specifically, site Supervisors shall ensure:  Electrical equipment wi ...
S824MCC/MCCH - P84478
S824MCC/MCCH - P84478

... locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for example, may require special precautions to assure electrical noise immunity (e.g. audio crosstalk). NOTE: This equipment has been tested and found to comply with ...
Feeder Protection - 123SeminarsOnly.com
Feeder Protection - 123SeminarsOnly.com

How to Prevent Power Surges:  Moxa White Paper
How to Prevent Power Surges: Moxa White Paper

... components of many modern automation systems; however, they are also particularly susceptible to power surges from voltage and current spikes because they typically have low dielectric strength. In these systems, serial device servers are key communications gateways that connect the broader Ethernet ...
MCP Indoor Call Point Range
MCP Indoor Call Point Range

LMS-3 ARRM System Installation Guide
LMS-3 ARRM System Installation Guide

... The Central Monitoring Station analyses the data received from the LMS-3, and displays graphically how the cable-sheath resistance to ground changes with time. The LMS-3 can be controlled locally, with a hand-held touch-sensitive display module, remotely over the Public Switch Telephone Network (PST ...
Electrical Measuring Instruments
Electrical Measuring Instruments

... As it’s very important that the insertion of the ammeter into a circuit has little effect the circuit’s existing resistance and, thus, alter the current normally flowing in the circuit, ammeters are manufactured with very low values of internal resistance. Because ammeters have a very low internal r ...
Evaluation of children presenting to the - Tubitak Journals
Evaluation of children presenting to the - Tubitak Journals

... patients and, consistent with our findings, they found that electric shocks were most often caused by contact with live electrical cords. This is why in-house precautions play an important role in preventing electric shocks. Consistent with the literature, the use of outlet plug covers, enacting reg ...
SDA-2000 数据资料DataSheet下载
SDA-2000 数据资料DataSheet下载

... Each amplifier stage in the SDA-2OOO is a cascade configuration. The gate of each upper FET in the cascade amplifiers is biased with the 3.5VDC (for VDD =8V). The DC connection for the upper device gates runs across the length of the die. Pads 2 and 5 are both on this DC connection but are on opposi ...
Analog Devices Welcomes Hittite Microwave Corporation
Analog Devices Welcomes Hittite Microwave Corporation

... The circuit board used in the final application should use RF circuit design techniques. Signal lines should have 50 ohm impedance while the package ground leads and backside ground slug should be connected directly to the ground plane similar to that shown. A sufficient number of via holes should b ...
pnm-31 voltage relay
pnm-31 voltage relay

... the device is equal with a loss of guarantee and can cause electric shock. Before installation make sure the connection cables are not under voltage. The cruciform head screwdriver 3,5 mm should be used to instal the device. Improper transport, storage, and use of the device influence its wrong func ...
voltage - International University of Sarajevo
voltage - International University of Sarajevo

... Experimental results reveal that the human body begins to react to currents of only a few milliamperes. Although most individuals can withstand currents up to perhaps 10 mA for very short periods of time without serious side effects, any current over 10 mA should be considered dangerous. ...
DOC
DOC

... E.g. a 2.5V bulb needs a 2.5V battery Provide a few examples of when the bulb may be brighter/dimmer and burn out. Ask children to explore what happens to the brightness of the bulb when more than one battery is used in a circuit. Ask them to make a simple circuit and suggest how they might measure ...
Name:
Name:

File - Go ELECTRONICS
File - Go ELECTRONICS

Power in AC Circuits
Power in AC Circuits

... use loads built to dissipate 10 kW each at this higher voltage. The loads, of course, would have to have greater resistance values to dissipate the same power as before (10 kW each) at a greater voltage than before. The advantage would be less current required, permitting the use of smaller, lighter ...
< 1 ... 268 269 270 271 272 273 274 275 276 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.