• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Power and Protection for Modern Tetrodes
Power and Protection for Modern Tetrodes

... Tetrode power amplifiers are coming back into fashion, after many years in which US amplifier builders have focused almost exclusively on triodes. The situation in Europe has been very different, because tetrodes never went away. In particular, there have been many developments in tetrode power supp ...
Advantages of IC-Based Hot-Swap Circuit
Advantages of IC-Based Hot-Swap Circuit

... downtime, personal injury and resulting lawsuits, replacement and repair costs, technician wages. This list could go on. The introduction of hot-swap capability can immediately offset system costs by allowing a smaller main power supply. Reducing the level of surge current that a power supply must d ...
DC generators
DC generators

... produce a rotating magnetic field (as in a three-phase synchronous motor) – a stationary conductor will see a varying magnetic field and this will induce a current – current is induced in the field coils in the same way that current is induced in the secondary of a transformer – this current turns t ...
basics_of_power_qual.. - IDEAL INDUSTRIES, INC.
basics_of_power_qual.. - IDEAL INDUSTRIES, INC.

... • This is one reason that conduit makes such a good ground for noise- the higher frequencies run on the surface of the conduit. © 2007 Ideal Industries www.idealindustries.com ...
BD71L4LG-1
BD71L4LG-1

... The detection and release voltages are used as threshold voltages. When the voltage applied to the VDD pins reaches the appropriate threshold voltage, the OUT terminal voltage switches from either “High” to “Low” or from “Low” to “High”. Please refer to the Timing Waveform and Electrical Characteris ...
Surface Resistivity and Static Decay
Surface Resistivity and Static Decay

Basic Precipitator Troubleshooting
Basic Precipitator Troubleshooting

... Basic Precipitator Troubleshooting Comparing like areas of the precipitator can reveal problems that are not obvious from a glance of the electrical readings ...
AI21212221
AI21212221

... 1. INTRODUCTION With increasing applications of nonlinear and electronically switched devices in distribution systems and industries, powerquality (PQ) problems, such as harmonics, flicker, and imbalance have become serious concerns. In addition, lightning strikes on transmission lines, switching of ...
MLVDS Standard
MLVDS Standard

... by the driver output transition times, the media characteristics, and the distance between the driver and the load. Certain applications may impose a different (lower or higher) limit for the maximum signaling rate. This may be accomplished by specifying a different minimum driver transition time sp ...
Interconnection Guideline
Interconnection Guideline

Driving the Golden DRAGON LED Application Note
Driving the Golden DRAGON LED Application Note

... current. This means the Golden DRAGON LEDs only need to run at about 280mA, and there is still a surplus of light. By adding one LED to the string, the supply now has to drop 6.2V. In addition, with the LEDs operating at 280mA, the power to dissipate in the current control supply is 1.74W. This is m ...
GuitarCenter manual.q
GuitarCenter manual.q

... same outstanding sonic quality and reliability that has contributed to Hafler’s enviable reputation within professional recording studios and broadcast facilities all over the world. This manual contains information on using the TA1100 and TA1600 amplifiers. It is organized into two main sections. “ ...
MS-322 - ERS Biomedical
MS-322 - ERS Biomedical

... unit) AND MUST BE PROPERLY GROUNDED FOR SAFETY. The three wire power cord with "hospital grade" plug should be connected to a GROUNDED AC wall receptacle. It is the personal responsibility and obligation of the user to insure that this instrument is properly connected to the AC POWER source before u ...
ESD8008 - ESD Protection Diode
ESD8008 - ESD Protection Diode

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC) or its subsidiaries in the United States and/or other countries. SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent ...
L44086268
L44086268

... undersized in the past, it may now be necessary to run a second neutral wire that is the same size as the phase conductors. This is particularly important with some modular office partition-type walls, which can exhibit high impedance values. The operating limits of transformers and motors should be ...
IEC specifications for LV assembly switchboards
IEC specifications for LV assembly switchboards

... These voltage stresses and the relating rated characteristics will be used to design and verify insulation for basic and fault insulation (see clause 7 of IEC 61439-1&2), as well as functional insulation, between active conductors, necessary for proper functioning of the Assembly. Creepage distances ...
C7804 Electric Components newer
C7804 Electric Components newer

... flow through them in one direction only. They behave like an electronic “one way street”. Diodes have polarity. They have two terminals known as the cathode (C) and the anode (A). The diode allows current to flow through it only when the cathode is negative and the anode is positive. The figure show ...
TBS. Surge protection systems/Measurement and
TBS. Surge protection systems/Measurement and

... Lightning barriers VF and VF-FS are used as precision protection devices in power supplies for computer installations, modems, ripple control installations, etc., to protect them from surges that may be caused by atmospheric discharges (storms) or switching operations. The built-in protection circui ...
DN302 - Ultraprecise Instrumentation Amplifier Makes Robust Thermocouple Interface
DN302 - Ultraprecise Instrumentation Amplifier Makes Robust Thermocouple Interface

... Since the LTC2053 operates by sampling the input signal, the frequencies of interest are generally below a few hundred Hz so it is useful to rolloff the amplifier response by adding 0.1μF in the feedback circuit. The capacitors in the thermocouple input network help absorb RF pickup and suppress samp ...
Primatics, Inc
Primatics, Inc

... Note the places in the workcell where pinch points occur, and provide adequate safety clearance or safety curtain. ...
its-50c transfer switch
its-50c transfer switch

... powercord, the test may only hi-pot the cord itself; it may not test the RV wiring beyond the switch. The hi-pot test should be performed from either the transfer switch output or from the main panel. Test as follows: I. Turn on all circuit breakers in the panel. II. Make sure the generator is off. ...
An Approach to the Low-Resistance Measurement
An Approach to the Low-Resistance Measurement

... The DC parasitic voltage correction does not depend on controller clock frequency [6]. But the dominant role of AC disturbances has the influence on power network (50 Hz). It has turned out that the effect of that circuit, the sample and hold output circuits as well, is very much dependent on the ph ...
MAX17019 Evaluation Kit Evaluates: General Description Features
MAX17019 Evaluation Kit Evaluates: General Description Features

Messungen - Universität Stuttgart
Messungen - Universität Stuttgart

... 333 MVA autotransformer. This interference signal disturbs the earth connection, which consist for the first FRA measurement of normal wire and for the second FRA measurement of ground strap. The results of this experiment show that the interference liability of a ground strap is much less than that ...
MAX1479 300MHz to 450MHz Low-Power, Crystal-Based +10dBm ASK/FSK Transmitter General Description
MAX1479 300MHz to 450MHz Low-Power, Crystal-Based +10dBm ASK/FSK Transmitter General Description

< 1 ... 175 176 177 178 179 180 181 182 183 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report