• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX44299 Current and Voltage Sense with Power Measurement
MAX44299 Current and Voltage Sense with Power Measurement

... Full-Scale Output Current Select. Connect ISET to ground or leave it unconnected to select the full-scale output current of 100µA. ...
Team D - Electrical Engineering @ NMT
Team D - Electrical Engineering @ NMT

... energy draw power from ongoing natural processes, their operation does not incur the costs of fuel and waste disposal which are associated with conventional electric generators. For the same reason, energy sources such as wind turbines cause much less long-term or irreversible damage to the environm ...
BU52072GWZ - ROHM Semiconductor
BU52072GWZ - ROHM Semiconductor

... when distance increases magnetic density falls. When it drops below the operate point (B op), output goes HIGH. When the magnet gets closer to the IC and magnetic density rises to the operate point, the output switches LOW. In LOW output mode, the distance from the magnet to the IC increases again u ...
File - Electrical Engineering
File - Electrical Engineering

... SCRs with center-tapped reactors is shown below. ...
FSGM0565RB Green-Mode Fairchild Power Switch (FPS™)  FSGM
FSGM0565RB Green-Mode Fairchild Power Switch (FPS™) FSGM

... stop voltage again. In this manner, the auto-restart can alternately enable and disable the switching of the power SenseFET until the fault condition is eliminated. Because these protection circuits are fully integrated into the IC without external components, the reliability is improved without inc ...
AP2552-53(A) - Diodes Incorporated
AP2552-53(A) - Diodes Incorporated

... 5. External capacitors need to be connected to the output, EVM board was tested with capacitor 2.2uF 50V 0805. This level is a pass test only and not a limit. ...
Average Power Balancing Control of a STATCOM based on the
Average Power Balancing Control of a STATCOM based on the

P84396
P84396

... locating Notification Appliance Circuits (NAC) and notification appliances. Some system communication circuits and/or audio circuits, for example, may require special precautions to assure electrical noise immunity (e.g. audio crosstalk). NOTE: This equipment has been tested and found to comply with ...
Universal input voltage power supply for ESBT based breaker and
Universal input voltage power supply for ESBT based breaker and

DS2731 Cache-Memory Battery-Backup Management IC General Description Features
DS2731 Cache-Memory Battery-Backup Management IC General Description Features

Power Distribution Systems
Power Distribution Systems

... these facilities. Special equipment and special conditions such as emergency systems, standby systems and communication systems are also covered in the code. It is the responsibility of the design engineer to be familiar with the NFPA and NEC code requirements as well as the customer’s facility, pro ...
Universal AC Input, 5 Volt Output, 20 Watt Power Supply
Universal AC Input, 5 Volt Output, 20 Watt Power Supply

... equipment, or white goods where isolation from the AC mains is required, and low cost, high efficiency, low standby power are essential. The featured power supply is a simple CCM flyback topology utilizing ON Semiconductor’s new NCP1136 monolithic switcher with integral 4-ohm, vertical channel MOSFE ...
Generic risk assessment 5.1: incidents involving electricity
Generic risk assessment 5.1: incidents involving electricity

... countrywide grid through which the electricity can be carried to the local networks. Voltages of the distribution network are normally between 400,000 and 132,000 volts and may be carried on over ground pylons or laid underground. Over ground cable height means that the cables are generally inaccess ...
CONSONANCE
CONSONANCE

... The selection of output capacitor (C3 in Figure 1) is primarily determined by the ESR required to minimize ripple voltage and load step transients. it is best that the input capacitor consists of the following 2 capacitors in parallel:  A 10uF electrolytic capacitor for low-frequency filtering  A ...
AP3171 N E W P R O D U C T Description Features Pin
AP3171 N E W P R O D U C T Description Features Pin

... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
LM124/LM224/LM324/LM2902 Low Power Quad Operational
LM124/LM224/LM324/LM2902 Low Power Quad Operational

... The input common-mode voltage of either input signal voltage should not be allowed to go negative by more than 0.3 V (at 25°C). The upper end of the common-mode voltage range is V+ − 1.5 V (at 25°C), but either or both inputs can go to 32 V without damage (26 V for LM2902-N), independent of the magn ...
The Electricity at Work Regulations 1989. Guidance on
The Electricity at Work Regulations 1989. Guidance on

... 18 The reference in the definition to a common source of electrical energy does not exclude systems fed by several generators or transformers. The word ‘common’ is included in the definition so that completely independent electrical installations are regarded as separate systems. If, however, they ...
Protection Fundamentals - Levine Lectronics and Lectric
Protection Fundamentals - Levine Lectronics and Lectric

... protection, metering and management devices • Used in three-phase, high-power industrial, commercial and utility applications • Covers a variety of actual uses, including motor control, distribution panels and outdoor switchyards • The term "switchgear" is plural, even when referring to a single swi ...
lecture 1 - Rose
lecture 1 - Rose

SLIM_5125_User_Handbook_G14217_1.0
SLIM_5125_User_Handbook_G14217_1.0

Worst Case Power/Ground Noise Estimation Using an Equivalent
Worst Case Power/Ground Noise Estimation Using an Equivalent

... imum allowable average noise within a clock cycle and 2) the maximum allowable peak noise. The average noise determines the amount of variation in the delay of a critical path, that is, the maximum operating frequency of the circuit under power supply variations is dependent upon the average noise. ...
US6M2 - Rohm
US6M2 - Rohm

... The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants cont ...
Power and Protection for Modern Tetrodes
Power and Protection for Modern Tetrodes

... Tetrode power amplifiers are coming back into fashion, after many years in which US amplifier builders have focused almost exclusively on triodes. The situation in Europe has been very different, because tetrodes never went away. In particular, there have been many developments in tetrode power supp ...
Evaluation Board User Guide UG-336
Evaluation Board User Guide UG-336

... Evaluation Board User Guide ...
BD71L4LG-1
BD71L4LG-1

... The detection and release voltages are used as threshold voltages. When the voltage applied to the VDD pins reaches the appropriate threshold voltage, the OUT terminal voltage switches from either “High” to “Low” or from “Low” to “High”. Please refer to the Timing Waveform and Electrical Characteris ...
< 1 ... 174 175 176 177 178 179 180 181 182 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report