* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Workshop Materials
Mercury-arc valve wikipedia , lookup
Stepper motor wikipedia , lookup
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Transformer wikipedia , lookup
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Schmitt trigger wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power electronics wikipedia , lookup
Power MOSFET wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Ground (electricity) wikipedia , lookup
Three-phase electric power wikipedia , lookup
Transformer types wikipedia , lookup
History of electric power transmission wikipedia , lookup
Voltage regulator wikipedia , lookup
Buck converter wikipedia , lookup
Surge protector wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Distribution management system wikipedia , lookup
Fault tolerance wikipedia , lookup
Opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Mains electricity wikipedia , lookup
Protective relay wikipedia , lookup
Alternating current wikipedia , lookup
DISTRIBUTED GENERATION ISSUES •Technical Issues •Non-Technical Issues Technical Issues •DG Size •The greater the DG size, the higher the fault duty capacity •Location and type of fault •Contribution of DG to fault on the feeder reduces expected current for substation relays. They must be able to see faults at the end of the circuit. Technical Issues (continued) •Configuration of interconnection transformer •Ungrounded windings greatly affect relay performance during grounded faults •If primary winding is delta and a phaseto-ground fault occurs on the grid, the current relays of the DG will not be as sensitive to it. DG voltage relays on the primary side must see rise in voltage. Technical Issues (continued) •Lowest expected feeder load compared to maximum generator output •DG is preferred not to back feed substation bus under minimal circuit loading •At all times of year, power must not be pushed back to substation transformer (generator could feed transmission fault) Technical Issues (continued) •Voltage issues near DG site •Voltage on feeder must not be outside of allowable range due to presence of DG •Undesired voltage regulation on circuit must not result during low circuit loading Non-Technical Issues •Customer’s system configuration and operation with DG •Understanding prints and scheme involved •Need generator data to model DG •Increasing volume of DG applications