Environmental Conditions for the Eircom Advantage 4800
The control unit is comprised of three printed circuit boards (PCBs) housed with a
3-part plastic enclosure. The enclosure consists of an access cover, a top cover and a
base. Six slots in the top cover allow line and feature modules to be added.
The access cover encloses the connection area on which the wiring is terminated.
Installing and positioning the Advantage 4800 Control Unit
Select a location which is:
•
•
•
•
•
•
•
•
Approximately one metre from the ground for ease of installation
Easily accessible and well-lit to enable the wiring of the system
Isolated from plumbing and electrical wiring
Spacious enough to allow 300mm clearance around the system
Not exposed to electromagnetic radiation e.g. lift machinery, arc welders etc.
Within 2 metres of a dedicated electrical power point
Within convenient reach of the NTU (ISDN line socket) or incoming PSTN
wiring
Not exposed to extremes of temperature, humidity, dust, damp or direct
sunlight.
Installing and positioning the Battery Back-Up module
Select a location which is:
•
•
•
Not exposed to extremes of temperature, humidity, dust, damp or direct
sunlight.
Spacious enough to allow 150mm clearance around the casing
Within 2 metres of the Advantage 4800
Observe anti-static precautions
• Power down the system
• Remove the control unit main cover
• Mount the daughter card on the 4 mounting pillars above the power supply
ensuring that the pins of the 12 way connector line up
• If required, wall-mount the external battery enclosure using the template
supplied
• Terminate the interconnecting cable (system end first)
• Replace covers
• Power up the system
• Check operation with and without mains power.
•
The battery will last up to one hour depending on traffic
When adding or removing the encapsulated cards (e.g. line/extension) to the
Advantage 4800, the system MUST be powered down. If a battery back up module is
connected to the system this too MUST be disconnected.
Port Properties
When wiring extensions with 0.5mm copper conductor cable the following limits
should be adhered to:
100 ohms or 600m for Operafone Executive and single line display feature sets
504 ohms or 3 km for standard analogue two-wire sets
1,200 ohms or 7 km for analogue extensions programmed to be long-line extensions Note : This
to be available June 2004
Note : Any external wiring should have supplementary protection where deemed
appropriate. This can be provided using the following items
100000177 Oneac Kit
6089-1-810-00 Strip Connection 237A
6526-1-022-00 Krone Connection Box 50A
Additional line protectors and appropriate strips may be needed depending on
the size of the installation
2 x Relays, normally open contacts, max. Current 1 Amp
MOH
Phono socket input impedance 600 Ohms
Max input voltage 4 volts pk-pk
Paging
Phono socket input impedance 600 Ohms
Max output voltage 4 volts pk-pk
The Advantage 4800 is supplied with a protective earth connected.
No additional external earth connection is necessary.
There is a "Protective Bonding Conductor" (Earth Strap) internally in the system.
At one end, it connects to the terminal on the MDF, which is labelled “PE”, and at the
other end, it is connected to the third (Earth) terminal of the Mains connector in the
PSU. It is a length of Green-and-Yellow insulated wire of the same thickness and
type as the Earth wire in the three-core mains cable (to which it connects at the mains
terminal).
Fuse
1,6 Amp 250 Volt HBC (5mm x 20mm)
Dimensions of Advantage 4800
Height:
Width:
Depth:
Depth:
Weight of CCU without expansion modules
367 mm
425 mm
87 mm (without expansion modules)
152 mm (with expansion modules)
3.163 Kg
Dimensions of Battery Back-up module
12 Volt Lead Acid 6Ah
Height:
Depth:
Width:
Weight:
132 mm
80 mm
187 mm
2 Kg (including battery)
Operating Voltage
Mains voltage
Max power consumption
230 ± 10%
66 W
Environmental Specification
Operating temperature
Humidity
Maximum AC V/A:
Maximum input watts:
Maximum input current at 230Vac:
Maximum input current at 180Vac:
Power Factor:
Extreme working conditions
Storage temperature
Storage humidity
-5C to + 45C
10% to 90% non-condensing
120VA
66W
0.52A
0.67A
0.55
-15C to + 55C
-20%C to + 70%C
10% to 90% non-condensing
The space requirements are outlined below
Headset Compatibility on the
Operafone Executive Telephone Set
The full range of Plantronics ‘H’ Top Headsets will work on the Operafone Executive
Telephone Set. The headset will plug directly into the headset port using a Vista to
QD (Quick Disconnect) Cable. Details are below for your information.
Product
Range
Part
Code
Description
Operafone
Cable
26716-01
Vista Headset to QD (Quick Disconnect)
Supra
Tristar
Encore
DuoPro
32184-04
32186-04
33647-01
33693-01
33645-41
33699-41
33646-11
33705-11
36363-01
36366-01
36568-01
H51 Headset (One Ear + Headband)
H51N Noise Cancelling Headset (One Ear + Headband)
H81 Tristar Headset (Over One Ear)
H81N Noise Cancelling Tristar Headset (One Over Ear)
H91 Headset (One Ear + Headband + Treble / Bass Control)
H91N Noise Cancelling Headset (1 Ear + Headband + Treble/Bass Control
H101 Headset (Two Ear + Headband + Treble / Bass Control)
H101N Noise Cancelling Headset (Two Ear + Headband + Treble / Bass Control)
DuoPro H171 Combo Headset (One Ear+Headband & Over Ear)
DuoPro H171N Noise Cancelling Combo Headset (One Ear+Headband &
Over Ear)
DuoPro H181 Headset (Behind the Head)
Compatibility of eircom analogue phones with MDS Advantage 1200 & 4800 PABX
Last Number
Redial
Time Break
Recall
(transfer, etc)
Rings with a
different
Internal and
External Ring
Cadence
Message
Waiting
audible
indication
Message
Waiting visual
indication
Caller Display
(CLI)
Programmable
keys can be
Programmed
as MDS
PABX
function keys
ULYTEL II
PHONE
WITH
MESSAGE
WAITING
SIEMENS
EUROSET
2010
SIEMENS
EUROSET
2015
SIEMENS
GIGASET
4010
CLASSIC
SIEMENS
EIRCOM
4012
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No *
Yes
No*
Yes
Yes
Yes
Yes
Yes
Yes
No
Not
applicabl
e
No
Not
applicabl
e
Yes
Yes
No
Not
applicabl
e
No
Yes
Yes**
Yes
Yes
N/A
N/A
SIEMENS
EIRCOM
5012
COLOUR
SIEMENS
GIGASET
C 150
SIEMENS
EIRCOM
4012
MICRO
N/A
N/A
N/A
* Does not differentiate between Internal and External ring cadence. Rings with one cadence only.