In the above scenarios, if an interactive user session is rolled back, the user gets an
error message but is allowed to repeat the task. Instead, if a script session is rolled
back (for example, a script that generates a forecast plan or updates a job stream
definition), the script ends in failure.
Problems with Oracle
The following problems could be encountered with Oracle:
v “JnextPlan fails with the database message "The transaction log for the database
is full."”
v “You cannot do Oracle maintenance on UNIX after installation”
JnextPlan fails with the database message "The transaction
log for the database is full."
You receive a message from JnextPlan that includes the following database
message:
The transaction log for the database is full.
The JnextPlan message is probably the general database access error message
AWSJDB801E.
Cause and solution:
This scenario is described in “JnextPlan fails with the database message "The
transaction log for the database is full."” on page 100.
You cannot do Oracle maintenance on UNIX after installation
You have installed Tivoli Workload Scheduler, creating the installation directory
with the default root user permission. When you switch to the Oracle
administration user and try and use the Oracle tools, you encounter access
problems.
Cause and solution:
The problem could be that the Oracle administration user does not have "read"
permission for the entire path of the Tivoli Workload Scheduler installation
directory. For example, if you have created the Tivoli Workload Scheduler
installation directory as /opt/myProducts/TWS, the Oracle administration user must
have "read" permission for /opt and /myProducts, as well as /TWS.
Give the Oracle administration user read permission for the full path of the Tivoli
Workload Scheduler installation directory.