* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Power Supply (UED BW)
Pulse-width modulation wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Power factor wikipedia , lookup
Standby power wikipedia , lookup
Wireless power transfer wikipedia , lookup
Three-phase electric power wikipedia , lookup
Alternating current wikipedia , lookup
History of electric power transmission wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electric power system wikipedia , lookup
Ground (electricity) wikipedia , lookup
Audio power wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power engineering wikipedia , lookup
Electrification wikipedia , lookup
Rectiverter wikipedia , lookup
Earthing system wikipedia , lookup
Power over Ethernet wikipedia , lookup
Power supply unit (computer) wikipedia , lookup
Mains electricity wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power Supply Power Supply w/Line Conditioner • The power supply is the heart of the Millenium System. It can support between 15 DCD boards (power for locks and other devices provided by local power supplies. • In addition to providing board power, the power supply has an integrated line conditioner which generates the biasing voltage necessary for RS-485 communications and to filter out any noise or interference on the communications cabling. 2 Power Supply Spec’s • Input: – 120 VAC, 60 Hz, 2 AMPs unswitched circuit (P/N PS1-100212-001) – 240 VAC, 50 HZ, 2 AMPs unswitched circuit (P/N PS1-100213-001) • Output: – 13.8 VDC, @ 5 AMPs. • Backup Battery: – 6 VDC Lead Acid, @ 8 AH. (Two Batteries Required). • Fuses: – AC input fuse: 2 AMP, Slow Blow, Full Size Automotive Type. – Battery fuse: 8 AMP, Slow Blow, Full Size Automotive Type. • Alarm Outputs: – Form A for AC Power Fail. – Form A for Enclosure Cover Tamper. 3 Power Supply J3 Terminal Block F3 Line Conditioner F4 J3 J4 J3 is used for 120 VAC input connection. This should be wired by a qualified electrician. 4 Power Supply J4 Terminal Block F3 Line Conditioner F4 J3 J4 J4 is used for DC Power Out, AC Fail Supervison Relay, Cabinet Tamper, RS-485 Communications Power, and Earth Ground. 5 Power Supply F3 Fuse F3 Line Conditioner F4 J3 J4 F3 is the 8 amp Slow Blow Fuse for the Battery Protection Circuit 6 Power Supply F4 Fuse F3 Line Conditioner F4 J3 J4 F4 is the 2 amp Slow Blow Fuse for the AC Input. 7 Power Supply Line Conditioner Board IMPORTANT In a Standard Millenium System, one power supply with line conditioner must be used. F3 For a Millenium Windows System, each SCU must have at least one power supply on that branch that employs a Line Conditioner. In either system, the -TXR and the +TXR terminals are not used for the additionally required power supplies. Only the Signal Ground terminal is used to bond the power supplies together. Line Conditioner F4 J3 The Line Conditioner board is used to provide load and bias voltages for the RS-485 communications lines. 8 J4 AC Connections F3 Line Conditioner F4 J3 1 2 J4 3 tra eu N AC und ro t G Ho AC l 9 DC Output Connections F3 Line Conditioner F4 J3 J4 4 5 6 7 8 9 10 11 12 t Ou C t VD Ou 8 3. C +1 VD 8 3. -1 10 AC Fail Supervision Relay F3 Form A, Dry Contacts for AC Failure Supervision. Line Conditioner F4 J3 J4 4 5 6 7 8 9 10 11 12 OM il C . Fa N.C AC ail F AC 11 Enclosure Tamper Switch F3 Form A, Dry Contacts for Enclosure Tamper. Line Conditioner F4 J3 J4 4 5 6 7 8 9 10 11 12 M O rC . pe .C m rN T a m pe Ta 12 Communications Power Connections F3 Plus and Minus RS-485 Communications Biasing Voltage Pow er Source. Line Conditioner F4 J3 J4 4 5 6 7 8 9 10 11 12 ns t io ica ns u n io m at m nic Co mu XR om +T R C X -T 13 Signal Ground Connection F3 Earth Ground Connection. Main Connection for all Cable Shields. Line Conditioner F4 J3 J4 4 5 6 7 8 9 10 11 12 na g Si ro lG d un 14 Single Power Supply Application Main Pow er Supply SCU DCD #1 DCD #2 15 DCD #3 DCD #4 RCD #1 Connecting Multiple Power Supplies Main Pow er Supply Pow er Supply #2 SCU DCD #1 DCD #20 A common bonding wire must be run from the negative DC terminal of the main power supply to each additional power supply. 16 DCD #21 Only the shield of the communications cable is attached to terminal #12 for each additional power supply. Terminals #10 and #11 are not connected. Multi Floor Power Supplies 1st Floor Main Pow er Supply Pow er Supply SCU DCD #1 DCD #20 A common bonding wire must be run from the negative DC terminal of the main power supply to each additional power supply. DCD #21 Only the shield of the communications cable is attached to terminal #12 for each additional power supply. Terminals #10 and #11 are not connected. 2nd Floor Pow er Supply Pow er Supply DCD #30 DCD #31 DCD #40 17 DCD #41 Power Supply Tech Tips • AC must be wired by Qualified Electrician. • Earth Ground to Terminal 12. – – – – – Use Solid Core cable, AWG #10 or better. Less than 50 ft to ground source is ideal. Use 6” radius bends on the cable. No sharp 90º corners. Use mechanical ground clamp to attach wire to ground source. Use CWP, UFER ground, or some other verified and approved ground source. No Gas or Fire Sprinkler Pipe. • Create a monolithic shield for the signal ground. – Ground shielded cable on one end only. Tie down the shield to terminal 12. – The -TXR and +TXR terminals are not used on additional power supplies within the same SCU branch. Only the shield and a common negative is connected between power supplies to establish the bonded signal ground. 18 Power Supply Tech Tips • The Power Supply can only be loaded to a maximum of 80% of its current rating. – Maximum rating is 5 AMPs or 5000 mA. Eighty percent loaded is 4 AMPs or 4000 mA. • Replace fuses with like rated fuses. • Replace lead acid batteries every 3-5 years. • The Unican part number for the power supply is: 120 VAC, 60 Hz PS1-100212-001. 240 VAC, 50 Hz PS1-100213-001. • Power Supply part number includes batteries and a locking enclosure. 19 Power Supply Terminal Summary Label F3 F4 J4 J3 4 5 6 7 8 9 10 11 12 2 3 1 Signal GND +TXR -TXR Tamper COM Tamper N.C. AC Fail COM AC Fail N.C. +13.8 VDC OUT -13.8 VDC OUT AC Neutral AC GND AC Hot 20