Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
RIGOL User’s Guide DS1000B Series Digital Oscilloscopes DS1074B,DS1104B,DS1204B Jul. 2014 RIGOL Technologies, Inc. RIGOL Guaranty and Declaration Copyright © 2009 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is registered trademark of RIGOL Technologies, Inc. Publication Number UGA04122-1210 Notices RIGOL products are covered by P.R.C. and foreign patents, issued and pending. RIGOL Technologies, Inc. reserves the right to modify or change parts of or all the specifications and pricing policies at company’s sole decision. Information in this publication replaces all previously corresponding material. Information in this publication is subject to change without notice. RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing, use or performance of this manual as well as any information contained. Any part of this document is forbidden to copy or photocopy or rearrange without prior written approval of RIGOL. Product Certification RIGOL guarantees this product conforms to the national and industrial standards in China as well as the ISO9001:2008 standard and the ISO14001:2004 standard. Other international standard conformance certification is in progress. Contact Us If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: [email protected] Websites: www.rigol.com User’s Guide for DS1000B Series I RIGOL Safety Notices view the following safety precautions carefully before operating the instrument to avoid any personal injuries or damages to the instrument and any products connected to it. To avoid potential hazards use the instrument as specified by this user’s guide only. The instrument should be serviced by qualified personnel only. To Avoid Fire or Personal Injury. Use Proper Power Cord. Use the power cord designed for the instrument and authorized in your country only. Ground The Instrument. The oscilloscope is grounded through the grounding conductor of the power cord. To avoid electric shock the instrument grounding conductor(s) must be grounded properly, before making connections to the input or output terminals of the instrument. Connect The Probe. The probes’ ground terminals are at the same voltage level of the instrument ground. Do not connect the ground terminals to a high voltage. II Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and marks on the instrument. Follow the user’s guide for further ratings information before making connections to the instrument. Do Not Operate Without Covers. Do not operate the instrument with covers or panels removed. Use Proper Fuse. Use the fuse of the type, voltage and current ratings as specified for the instrument. Avoid Circuit or Wire Exposure. Do not touch exposed connections and components when power is on. Do Not Operate With Suspected Failures. If suspected damage occurs with the instrument, have it inspected by qualified service personnel before further operations. Provide Proper Ventilation. Refer to the installation instructions for proper ventilation of the instrument. Do Not Operate in Wet Conditions In order to avoid short circuiting to the User’s Guide for DS1000B Series RIGOL interior of the device or electric shock, please do not operate in a humid environment. Do Not Operate in an Explosive Atmosphere In order to avoid damages to the device or personal injuries, it is important to operate the device away from an explosive atmosphere. Keep Product Surfaces Clean and Dry To avoid the influence of dust and/or moisture in air, please keep the surface of device clean and dry. The disturbance test of all the models meet the limit values of A in the standard of EN 61326: 1997+A1+A2+A3, but can’t meet the limit values of B. Measurement Category The DS1000B series Digital Oscilloscope is intended to be used for measurements in Measurement Category I. User’s Guide for DS1000B Series Measurement Category Definitions Measurement Category I is for measurements performed on circuits not directly connected to MAINS. Examples are measurements on circuits not derived from MAINS, and specially protected (internal) MAINS derived circuits. In the latter case, transient stresses are variable; for that reason, the transient withstand capability of the equipment is made known to the user. WARNING IEC Measurement Category I, the input terminals may be connected to circuit terminal in IEC Category I installations for voltages up to 300 VAC. To avoid the danger of electric shock, do not connect the inputs to circuit’s voltages above 300 VAC. Transient overvoltage is also present on circuits that are isolated from mains. The DS1000B series Digital Oscilloscopes is designed to safely withstand occasional transient overvoltage up to 1000 Vpk. Do not use this equipment to measure circuits where transient overvoltage could exceed this level. III RIGOL Safety Terms and Symbols Terms in this Manual. These terms may appear in this manual: ! WARNING Warning statements indicate the conditions or practices that could result in injury or loss of life. ! CAUTION Caution statements indicate the conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER indicates an injury or hazard that may immediately happen. WARNING indicates a potential injury or hazard that may immediately happen. CAUTION indicates a potential damage to the instrument or other property that may occur. Symbols on the Product. These symbols may appear on the product: ! Hazardous Voltage IV Safety Warning Protective Earth Terminal Chassis Ground Test Grounding User’s Guide for DS1000B Series RIGOL General-Purpose Oscilloscopes The introduction of this document contains three types of DS1000B series oscilloscope: DS1074B, DS1104B and DS1204B RIGOL DS1000B series digital oscilloscopes with four analog channels in connection with an external trigger channel are designed to capture multiple signals and meet the needs of measurement along with its excellent performance, powerful functions. The instrument is designed for 2GSa/s maximum real-time sample rate, 50GSa/s maximum equivalent sample rate and 200MHz maximum bandwidth. Besides, abundant trigger modes, math and acquire functions enable it easy to capture and analyze waveforms, also, Auto button is available to display a signal automatically. What’s more, the laconic and clear panel in line with tradition and the intuitive on the panels make instrument operation easy and convenient, as well as the LCD, interface and buttons are all friendly and clear, making operation more comfortable. Main Features: Four Channels, Bandwidth of per channel: 200MHz: DS1204B 100MHz: DS1104B 70MHz: DS1074B 2GSa/s real-time sampling rate and 50GSa/s equivalent sampling rate. Color TFT 5.7 inch LCD, 320×240 pixels resolution. USB storage and PictBridge printing. Available to interconnect with RIGOL signal generator seamlessly. Adjustable waveform intensity, more effective waveform viewing. One-touch automatic setup, ease of use (AUTO). Storage and recurrence of Waveforms and setups, supports CSV, 8 or 24 bits bitmap and PNG format. Delayed Scan Function, easy to give attention to both details and overview of a waveform. 22 Automatic measurements. User’s Guide for DS1000B Series V RIGOL Automatic cursor tracking measurements. Waveform recorder, record and replay dynamic waveforms. Built-in FFT function. Digital filters, includes LPF, HPF, BPF, BRF. Pass/Fail detection Function, optically isolated Pass/Fail output. Addition, Subtract and Multiply Mathematic Functions of waveforms. Advanced trigger types include: Edge, Video, Pulse width, Pattern, Alternative. Adjustable trigger sensitivity. Multiple Language User Interface. Pop-up menu makes it easy to read and easy to use. Built-in help systems with multinational languages. Easy-to-use file system supports Chinese & English characters file name input. Conform to LXI consortium instrument standard class C. VI User’s Guide for DS1000B Series RIGOL Document Overview Chapter 1 Quick Start To introduce the panls and menus to help users to realize the base operations. Chapter 2 Operating Your Oscilloscope More details to help users to understand the functions and measurements of instrument deeply. Chapter 3 Application Examples To show the measurement functions directly by application examples. Chapter 4 Troubleshooting Provide you troubleshooting to solve the problems during operating. Chpter 5 Specifications List common specifications and characteristics of the oscilloscope. Chapter 6 Appendix Information about accessories, warranties, services and supports and the like. User’s Guide for DS1000B Series VII RIGOL Contents Guaranty and Declaration........................................................................ I Safety Notices......................................................................................... II General-Purpose Oscilloscopes ..................................................................V Chapter 1 Quick Guide ...................................................................... 1-1 General Inspect .................................................................................... 1-2 Panels and User Interface ...................................................................... 1-3 Functional Check ................................................................................... 1-7 To Compensate the Probes .................................................................... 1-9 To Display a Signal Automatically.......................................................... 1-10 To Understand the Vertical System ....................................................... 1-11 To Understand the Horizontal System ................................................... 1-13 To Understand the Trigger System........................................................ 1-15 To Understand the Quick Function ........................................................ 1-17 Chapter 2 Operating Your Oscilloscope ............................................. 2-1 To Set up the Vertical System ................................................................ 2-2 Channel Settings ............................................................................ 2-4 Math Function .............................................................................. 2-14 REF Function ................................................................................ 2-20 To Set up the Horizontal System........................................................... 2-28 Delayed Scan ............................................................................... 2-31 X-Y Format ................................................................................... 2-32 To Set up the Trigger System ............................................................... 2-33 Edge Trigger ................................................................................ 2-34 Pulse Width Trigger....................................................................... 2-35 Video Trigger................................................................................ 2-36 Pattern Trigger ............................................................................. 2-39 Alternative Trigger ........................................................................ 2-41 Trigger Settings ............................................................................ 2-44 To Set up the Sampling System ............................................................ 2-50 To Set up the Display System ............................................................... 2-54 To Store and Recall ............................................................................. 2-57 To Set up the Utility ............................................................................ 2-66 The I/O Setup .............................................................................. 2-68 Language .................................................................................... 2-76 Pass/Fail ...................................................................................... 2-77 VIII User’s Guide for DS1000B Series RIGOL Waveform Recorder ...................................................................... 2-80 Print Setting ................................................................................. 2-84 Self-Calibration ............................................................................. 2-88 System Information ...................................................................... 2-89 Date and Time ............................................................................. 2-91 To Measure Automatically .................................................................... 2-92 Quick Measurement Setup ............................................................. 2-94 Delay/Phase Setup ....................................................................... 2-95 Voltage Measurements .................................................................. 2-96 Time Measurements ..................................................................... 2-98 To Measure with Cursors ................................................................... 2-101 Manual Mode ............................................................................. 2-102 Track Mode ................................................................................ 2-104 Auto mode ................................................................................. 2-106 To Use Run Control Buttons ............................................................... 2-107 Chapter 3 Application Examples ........................................................ 3-1 Example 1: Taking Simple Measurements ................................................ 3-1 Example 2: View a Signal Delay Caused by a Circuit ................................. 3-2 Example 3: Capture a Single-Shot Signal ................................................. 3-3 Example 4: To Reduce the Random Noise on a Signal .............................. 3-4 Example 5: Making Cursor Measurements ............................................... 3-6 Example 6: The Application of the X-Y operation ...................................... 3-8 Example 7: Triggering on a Video Signal ............................................... 3-10 Example 8: FFT Cursor Measurement .................................................... 3-12 Example 9: Pass/Fail Test .................................................................... 3-13 Chapter 4 Troubleshooting ................................................................ 4-1 Chapter 5 Specifications.................................................................... 5-1 Technical Specifications ................................................................... 5-2 General Specifications ..................................................................... 5-6 Chapter 6 Appendixes ....................................................................... 6-1 Appendix A: DS1000B series Accessories ................................................. 6-1 Appendix B: Warranty ........................................................................... 6-2 Appendix C: General Care and Cleaning .................................................. 6-3 Index ...................................................................................................... 1 User’s Guide for DS1000B Series IX RIGOL Chapter 1 Quick Guide This chapter covers the following topics: General Inspect Panels and User Interface Functional Check To Compensate the Probes To Display a Signal Automatically To Understand the Vertical System To Understand the Horizontal System To Understand the Trigger System To Understand the Quick Function User’s Guide for DS1000B Series 1-1 RIGOL General Inspect After receiving a new DS1000B series oscilloscope, please inspect the instrument as follows: 1. Inspect the shipping container for damage. Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both electrical and mechanical test. The consigner or carrier shall be liable for the damage to instrument resulting from shipment, without free maintenance or replacement by RIGOL. 2. Inspect the instrument. In case of any damage, or defect, or failure, notify your RIGOL Sales Representative. 3. Check the accessories. Accessories supplied with the instrument are listed in "Appendix A: DS1000B series Accessories" in this guide. If the contents are incomplete or damaged, please notify your RIGOL Sales Representative. 1-2 User’s Guide for DS1000B series RIGOL Panels and User Interface Being familiar with the operation panels is the first priority when you get a new DS1000B series digital oscilloscope. This chapter will bring you a brief introduction and description of the panels and functions of oscilloscope, which can help users to know well about the instrument in a short time. Front Panel Figure 1-1, the front Panel; the knobs are used most often and are similar to the knobs on other oscilloscopes. There are five grey buttons defined as No.1 to No.5 from up to bottom on the right side of the display which are menu operating buttons. The buttons not only allow you to use some of the functions directly but also bring up soft button menus on the screen, which enable the access to many measurement features associated with the advanced functions, mathematics, and reference or to run control features. Turn On/ Off Menu LCD Multi-Function Quick Knob Button Function Run Menu Control Horizontal Trigger Vertical Power Switch USB Host Probe Compensator Menu Buttons Analog Signal Channels EXT TRIG Channel Figure 1-1 Front Panel Overview User’s Guide for DS1000B Series 1-3 RIGOL Front Panel Interfaces: USB Host: Connect DS1000B with external USB devices when the oscilloscope is regarded as “Host Device”, such as connecting a USB flash device. Analog Signal Channels: Four channels are provided: CH1, CH2, CH3 and CH4. EXT TRIG Input: It is applied to input external trigger signal. NOTE: There are two USB Host ports respectively on the front and rear panel. Rear Panel ① ② ③ ④ ⑤ ⑥ Figure 1-2 Rear Panel Overview Rear Panel of DS1000B contains the following parts: Power Supply: Input power supply to the instrument. Fuse: 250V, T2A Power Switch: Turn on or off the power source. LAN: Enable users to set up network by LAN port. USB Device: Connect DS1000B with external USB devices when the oscilloscope is regarded as “Slave Device”. For example: connect with PC for remote control. ⑥ USB Host: Connect DS1000B with external USB devices when the oscilloscope is regarded as “Host Device”, such as connecting a USB flash device. ① ② ③ ④ ⑤ 1-4 User’s Guide for DS1000B series RIGOL Notation definitions in this Manual: Throughout this guide, notation symbols of buttons and knobs are the same of those on front-panel. A box around the name of the key denotes MENU function buttons on front-panel, such as Measure. ( denotes the five SCALE knobs. denotes the LEVEL knob. The name with a drop shadow denotes the menu operating key, such as Waveform soft key in Storage menu. Arrow “→” is used to divide operation steps. Such as: Storage → Storage, indicates press “Storage” button on the front panel, then press “Storage” menu. ) denotes the multi-function knob . denotes the five POSITION knobs. User’s Guide for DS1000B Series 1-5 RIGOL User Interface Run Status Timebase U-Disk Location of Waveform Connected Window in Memory Trigger Point in Memory Trigger Point in Waveform Window Trigger Symbol CH1 Menu CH2 CH3 Waveform Display Window CH4 CH1 Volts/div CH2 Volts/div CH3 Volts/div CH4 Volts/div Figure 1-3 User Interface Overview 1-6 User’s Guide for DS1000B series RIGOL Functional Check Perform this quick functional check to verify that the instrument is operating correctly. 1. Turn on the instrument Use the power cord designed for the oscilloscope only to connect the instrument and AC power which delivers 100 to 240 VACRMS, 45Hz to 440Hz. Press the power switch to turn on the instruments, waiting until the display shows the waveform window. 2. Recall factory setting Press Storage → Storage → Factory → Recall, to recall factory setting. Storage Button Power Switch Figure 1-4 Button explanation ! WARNING To avoid electric shock, be sure the oscilloscope is properly grounded. 3. Input a signal to a channel of the oscilloscope Push BNC plug of probe into CH1 BNC connector, then twist the BNC cable to right to lock the probe in place. Switch on the probe to 10X [1]. Press CH1 → Probe → 10X to set probe attenuation of the oscilloscope, so as to make sure the measurement result is correct (Default probe attenuation scale is 1X). User’s Guide for DS1000B Series 1-7 RIGOL Figure 1-5 Probe connection Figure 1-6 Probe adjustment [1] Attach the probe tip to the Probe compensator connector and the reference lead to the ground pin. Press Auto, within a few seconds, a square wave will display (approximately 1kHz, 3Vpp). Push the OFF button or push the CH1 button again to turn off Channel 1. Push the CH2, CH3, CH4 buttons to turn on other channels, repeat step 2&3. NOTE: Signal outputed from the Probe compensator is ONLY used for probe compensation, not for calibration. Note: [1] For DS1204B, the standard probe is RP3300A which attenuation ratio is fixed at 10X and does not need to be adjusted. 1-8 User’s Guide for DS1000B series RIGOL To Compensate the Probes Perform this adjustment to match the characteristics of the probe and the channel input. This should be performed whenever attaching a probe to any input channel at the first time. 1. From CH1 menu, set the Probe attenuation to 10X (press CH1→Probe→10X). Set the switch to 10X on the probe [1] and connect it to CH1 of the oscilloscope. When using the probe hook-tip, inserting the tip into the hook-tip firmly to ensure a tight connection. 2. Attach the probe tip to the connector of the Probe compensator and link the reference wire cramp with the ground connector of the probe compensator, Select CH1, and then press Auto. 3. Check the shape of the displayed waveform. Over Compensated Correctly Compensated Under Compensated Figure 1-9 Figure 1-7 Compensate waveform 4. If necessary, use a non-metallic tool to adjust the variable capacitor of the probe for the flattest square wave being displayed on the oscilloscope. 5. Repeat if necessary. ! WARNING To avoid electric shock while using the probe, be sure the perfection of the insulated cable, and do not touch the metallic portions of the probe head while it is connected with a voltage source. Note: [1] For DS1204B, the standard probe is RP3300A which attenuation ratio is fixed at 10X and does not need to be adjusted. User’s Guide for DS1000B Series 1-9 RIGOL To Display a Signal Automatically The oscilloscope has an automated feature to display the input signal in best-fit status. The input signal should be 50 Hz or higher and a duty cycle is greater than 1%. Using the automatic setting: 1. Connect a signal to the oscilloscope (such as channel 1) as described above. 2. Press Auto. The oscilloscope may change the current settings to display the signal; adjusts the vertical and horizontal scaling, the trigger coupling, type, position, level, and mode. 1-10 User’s Guide for DS1000B series RIGOL To Understand the Vertical System As shown in Figure 1-8, there are several buttons and knobs in the VERTICAL control area, which are used for setting Channels, MATH and REF functions as well as adjusting vertical position and Volts/div of waveforms. In addition, different colors are designed for different channels, corresponding to different waveforms, so as to observe clearly. Figure 1-8 Vertical control 1. Press CH1, CH2, CH3, CH4, MATH, REF, the operating menus, symbols, waveforms and status information of corresponding channel and settings will be displayed on the screen. The current selected channel will be shut down when you press the key associated with the channel one more time. 2. Set vertical position of waveform display by knob. Turning the knob, a voltage value is displayed for a short time indicating its value with respect to the ground reference located at the center of the screen. Also notice that the ground symbol on the left side of the display moves in conjunction with the knob. User’s Guide for DS1000B Series 1-11 RIGOL Measurement hints If the channel is DC coupled, measuring the DC components of the signal by simply noting its distance from the ground symbol. If the channel is AC coupled, the DC component of the signal is blocked, allow you to use greater sensitivity to display the AC component of the signal. Vertical offset back to 0 shortcut key Turn the knob to change the vertical display position of channel and press the knob to set the vertical display position back to 0 as a shortcut key, this is especially helpful when the trace position is far out of the screen and want it to get back to the screen center immediately. 3. Set vertical “Volts/div” by knob. Rotate to change “Volts/div”, the change will be displayed in real time at the bottom of interface. Besides, the “Volts/div” contains two forms: “Fine” and “Coarse”. Coarse/Fine Shortcut key The Coarse/Fine vertical control can be set by simply pressing the vertical knob. 1-12 User’s Guide for DS1000B series RIGOL To Understand the Horizontal System Figure1-9 shows the HORIZONTAL controls: MENU button, and knobs of horizontal system. Following the exercise to familiarize with the buttons, knobs, and status bar. Figure 1-9 Horizontal control 1. knob. Set horizontal “s/div” by knob changes the sweep speed in a 1-2-5 step The horizontal sequence, and displays the value at the upper-left of the display. The time base ranges of the DS1000B series is from 2 ns/div* to 50 s/div. Delayed Scan Shortcut key To press the knob in the horizontal control area on the front-panel is another way to enter or exit Delayed Scan mode and it is equal to the menu operations, MENU→Delayed→ON. NOTE*: The speed of horizontal scan varies by different models. 2. Press MENU button to display the “Horizontal” menu. Users can set the delayed state, time base expansion, time base mode and trigger offset. Term Explanations Trig-Offset: Denotes the real position of the trigger point relative to the midpoint of the memory. In this setting, the trigger position will be changed horizontally when you turning the knob. User’s Guide for DS1000B Series 1-13 RIGOL 3. The horizontal knob moves displayed signal horizontally on the waveform window. The horizontal knob adjusts the trigger offset of signal, when turning the knob; you can note that the waveform moves horizontally in conjunction with the knob. Horizontal offset back to 0 shortcut key Rotate the horizontal knob to adjust the horizontal position of the signal in the waveform window and press it down to restore the trigger offset or (delayed sweep offset) to the zero point. 1-14 User’s Guide for DS1000B series RIGOL To Understand the Trigger System Figure 1-10 shows the TRIGGER control: MODE, MENU, FORCE, 50% and a knob. Following the exercises to familiarize with the buttons, trigger level knob and status bar. Figure 1-10 Trigger control 1. Three kinds of trigger modes can be switched among Auto, Normal and Single with pressing MODE button. 2. Use the knob to change the settings of trigger level. Turning the knob, you will observe an orange trigger line, a trigger sign and a trigger level value displaying pane on the screen moving up and down. knob, the trigger line, trigger sign and When you stop turning the trigger value pane will disappear in five seconds. During the same time of moving the trigger line, you will notice that the displayed value of trigger level has been changed on the screen. Trigger Level back to 0 Shortcut key Turn the knob to change the trigger level value and press the knob to set trigger level back to 0 as a shortcut key. User’s Guide for DS1000B Series 1-15 RIGOL 3. Press MENU button in the Trigger control area. A soft button menu appears on the display showing the trigger setting choices as shown in Figure 1-11. Figure 1-11 Press NO.1 menu button to choose Edge. Press NO.2 menu button to choose Source as CH1. Press NO.3 menu button to choose Slope as Press NO.4 menu button to choose Sweep as Auto. Press NO.5 menu button to enter secondary menu of Set Up. . c. NOTE: The change of trigger mode, source selection and slope type will lead to the change of the status bar on the upper-right of the screen. 4. Press FORCE Start an acquisition even if no valid trigger signal has been found, usually used in “Normal” or “Single” trigger mode. This button has no effect if the acquisition is already stopped. Switch Local/Remote mode 仪 Press FORCE button to switch the operation mode as “local” when the instrument is under remote mode. 5. 1-16 Press 50% Press the 50% button to set the trigger level to the center of the signal’s amplitude. User’s Guide for DS1000B series RIGOL To Understand the Quick Function The following figure shows that there are two buttons in the QUICK function area. The exercise below will gradually conduct you to familiarize the settings of the buttons. Figure 1-12 The quick function menu 1. Measure There are two Measure buttons on the front panel, belonging to Function Menu area and Quick Function area respectively. Firstly, you need to pre-set up three items from 22 measurements via Measure → QuickMea from Function Menu area, and then press Measure as shown in figure 1-12 to enter quick measurement, three measuring parameters pre-defined will be displayed on the screen. 2. Print Use Print button to perform a quick print or store data to USB flash device. To execute print operation if connecting the printer since it has a higher priority. To store the measurement results to USB flash device in current format such as Waveform, Setups, 8 Bitmap, 24 Bitmap, PNG or CSV. Furthermore, it will be stored as 8-Bitmap automatically when selecting “Factory”. User’s Guide for DS1000B Series 1-17 RIGOL Chapter 2 Operating Your Oscilloscope By now, a user should understand the VERTICAL, HORIZONTAL and TRIGGER control systems and know how to determine the system setup from the status bar of a DS1000B series digital oscilloscope. This chapter will go through all groups of front-panel buttons, knobs and menus; and further the knowledge of the operation by hints in this guide. It is strongly recommended to perform all of the following exercises to get the most of the powerful measurement capabilities of the oscilloscope. This chapter covers the following topics: To Set up the Vertical System (CH1, CH2, CH3, CH4, MATH, REF , Vertical , Vertical ) To Set up the Horizontal System (MENU, Horizontal Horizontal , ) To Set up the Trigger System (MODE, To Set up the Sampling System (Acquire) To Set up the Display System (Display) To Store and Recall (Storage) To Set up the Utility (Utility) To Measure Automatically (Measure) To Measure with Cursors (Cursor) To Use Run Control Buttons (Auto, Run/Stop, Single) , MENU, FORCE, 50%) Please read this chapter carefully to get more functions and operations about DS1000B series oscilloscopes. User’s Guide for DS1000B Series 2-1 RIGOL To Set up the Vertical System Four analog channels are provided by DS1000B: CH1, CH2, CH3 and CH4. Press the corresponding button on the front panel to turn the channels on/off. The backlight indicates the channel is currently active. Press the button again to turn the channel off. When channel is currently selected, press OFF will turn it off and the backlight goes off. Table 2-1 Channels menu Channel Status Indicator Channel 1 (CH1) Settings ON Selected OFF Channel 2 (CH2) ON Selected OFF CH2 (azure blue letters with black background) CH2 (black letters with blue background) No indicator Channel 3 (CH3) ON Selected OFF CH3 (pink letters with black background) CH3 (black letters with pink background) No indicator Channel 4 (CH4) ON Selected OFF CH4 (black letter with navy blue background) CH4 (navy blue letter with black background) No indicator MATH ON Selected OFF MATH (purple letter with black background) MATH (black letter with purple background) No indicator CH1 (yellow letters with black background) CH1 (black letters with yellow background) No indicator Other functions such as MATH and REF can be regarded as relatively isolated channels. 2-2 User’s Guide for DS1000B series RIGOL Knobs Explanation Use the vertical controls to display signal waveforms by adjusting the vertical knob, and the knob, and setting the input parameters. 1. Using vertical knob. The vertical control changes the vertical position of signal waveforms in all channels (excluding MATH and REF). The resolution changes according to the vertical level set. Pressing this knob will clear the channel’s vertical offset to zero. 2. Using vertical knob. The vertical control changes the vertical sensitivity of signal waveforms in all channels (excluding MATH and REF). If the Volts/Div is set to “Coarse”, the waveform scales in a 1-2-5 step sequence from 2 mV ,5mv,10mv…to 10 V. If the Volts/Div is set to “Fine”, it scales to small steps between the coarse settings. Turn the knob clockwise to decrease the vertical scale, turn the knob counter-clockwise to increase the vertical Volts/Div setting. You can toggle between “coarse” and “Fine” setting through pressing the knob. 3. During the vertical positioning, a position message is displayed on the left bottom of the screen, such as POS:32.4mv in the same color along with the corresponding channel. The unit is V (Volts). User’s Guide for DS1000B Series 2-3 RIGOL Channel Settings Each channel of DS1000B series digital oscilloscope has an independent operation menu and it will pop-up after pressing any button among CH1, CH2, CH3, CH4. The menu to set CH1 is shown in the table below. Press CH1 to enter the following menus. Figure 2-1 Table 2-2 Channel menu (Page 1/2) Menu Coupling Settings Comments AC Block DC component of the input Signal. Pass both AC and DC components of the input signal Disconnect the input signal. DC GND ON BW Limit OFF Probe 0.001X … 1000X Digital Filter Set up digital filter (See table 2-5). 1/2 2-4 Limit the channel’s bandwidth to 20MHz to reduce display noise. Get full bandwidth. Set up the probe attenuation factor by 1-2-5 to make the vertical scale readout correct. including: 0.001X,0.01X,0.1X,1X,2X,5X,10X,20 X,50X,100X,200X,500X,1000X Go to the next menu page (The followings are the same, no more explanation). User’s Guide for DS1000B series RIGOL Figure 2-2 Table 2-3 Channel menu (Page 2/2) Menu Settings Comments 2/2 Back to the previous menu page (The followings are the same, no more explanation). Volts/Div Coarse Fine Define a 1-2-5 sequence. To change the Volts/Dive settings in small steps between the coarse settings. Invert ON OFF Turn on the invert function. Restore to original display of the waveform. V/ A/ W/ U Set “V”, “A”, “W” or “U” as the unit of vertical channel. Unit User’s Guide for DS1000B Series 2-5 RIGOL 1. To set up channel coupling To use Channel 1 as an example, input a square wave signal with DC shift. Press CH1→Coupling→DC to set “DC” coupling. Both the AC component and the DC component of the input signal will pass. DC Coupling Setup DC Coupling Status Symbol Figure 2-3 DC coupling settings Press CH1→Coupling→AC, to set “AC” coupling. It will pass AC component of the input signal with frequency higher than 5 Hz and restraint DC component of the input signal. AC Coupling Setup AC Coupling Status Symbol Figure 2-4 AC coupling settings 2-6 User’s Guide for DS1000B series RIGOL Press CH1→Coupling→GND, to set “GND” coupling, it disconnects the input signal. The screen displays as Figure 2-5: GND Coupling Setup GND Coupling Status Symbol Figure 2-5 Ground coupling settings User’s Guide for DS1000B Series 2-7 RIGOL 2. To set up the channel bandwidth limit Take Channel 1 for an example, input a signal containing high frequency component. Press CH1→BW Limit→OFF, to set up bandwidth limit to “OFF” status. The oscilloscope is set to full bandwidth and passing the high frequency component in the signal. Turn off the BW Limit Figure 2-6 Turn off the BW limit Press CH1→BW Limit→ON, to set up bandwidth limit to “ON” status. It will restraint the frequency component higher than 20MHz. 20MHz BW limit Mark of BW limit Figure 2-7 Turn on the BW limit 2-8 User’s Guide for DS1000B series RIGOL 3. To set up Probe Attenuation The oscilloscope allows selecting the attenuation factor for the probe. The attenuation factor changes the vertical scaling of the oscilloscope so that the measurement results reflect the actual voltage levels at the probe tip. Figure 2-8 shows an example for using a 1000:1 probe and its attenuation factor. Probe Attenuation Vertical volts/div Figure 2-8 Set up probe attenuation coefficient Table 2-4 Probe setting Probe Attenuation Factors Corresponding Settings 1:1000 0.001X 1:100 0.01X 1:10 0.1X 1:1 1X 2:1 2X 5:1 5X 10:1 10X 20:1 20X 50:1 50X 100:1 100X 200:1 200X 500:1 500X 1000:1 1000X User’s Guide for DS1000B Series 2-9 RIGOL 4. Digital Filter Press CH1→ Digital Filter to display the digital filter menu. Turn Off Digital Filter Figure 2-9 Turn off digital filter Turn On Digital Filter Figure 2-10 Turn on digital filter Turn the digital filter on or off as shown in the following figure. Turn ( ) knob to adjust the upper and lower limit of frequency after turning on the digital filter. 2-10 User’s Guide for DS1000B series RIGOL Figure 2-11 Table 2-5 The Filter menu Menu Settings Comments Digital Filter ON OFF Turn on the digital filter. Turn off the digital filter. Filter Type Setup Setup Setup Setup as as as as Upper Limit[1] <frequency> Turn ( ) knob to set upper limit high limit. Lower Limit[1] <frequency> Turn ( LPF (Low Pass Filter). HPF (High Pass Filter). BPF (Band Pass Filter). BRF (Band Reject Filter). ) knob to set lower limit. Back to higher level menu (The followings are the same, no more explanation). NOTE: [1] The upper limit needs to be set in the type of low pass filter. The lower limit needs to be set in the type of high pass filter. Both upper limit and lower limit need to be set in the types of band pass filter and band reject filter. User’s Guide for DS1000B Series 2-11 RIGOL 5. To change the Volts/Div settings The Volts/Div control has Coarse or Fine configuration. The Vertical Sensitivity is 2mv/div - 10V/div. Coarse: It is the default setting of Volts/Div in a 1-2-5-step sequence from 2mV/div, 5mV/div, 10mV/div, to 10 V/div. Fine: This setting changes the vertical scale to small steps between the coarse settings. It will be helpful to adjust the waveform in smooth steps. Fine Adjustment Fine Adjustment Data Figure 2-12 Fine Adjustment Coarse/Fine Shortcut key To change Coarse/Fine setting, not only by menu but also by pressing vertical 2-12 knob. User’s Guide for DS1000B series RIGOL 6. To invert a waveform Invert turns the displayed waveform 180 degrees with respect to the ground level. When the oscilloscope is triggered on the inverted signal, the trigger is also inverted. Figure 2-13 and Figure 2-14 show the changes before and after the inversion respectively. Invert Off Figure 2-13 Waveform before inversion Invert On Figure 2-14 Waveform after inversion User’s Guide for DS1000B Series 2-13 RIGOL Math Function The mathematic functions include “add”, “subtract”, “Multiply” and “FFT” for CH1, CH2, CH3 and CH4. The mathematic result can be measured by the grid and the cursor. Press MATH button to enter “Math” menu, meanwhile, sign of math scale will appear under the screen. See figure below, waveform of CH1 is marked yellow, waveform of CH2 is marked blue, and waveform of CH1 adding CH2 is marked purple. Math Scale Figure 2-15 Math function Figure 2-16 Table 2-6 The Math menu (Page 1/2) Menu Operate Source A Source B Invert 2-14 Settings A+B A-B A×B FFT CH1, CH2, CH3, CH4 CH1, CH2, CH3, CH4 ON OFF Comments Add source A and source B. Subtract source B from source A. Multiply source B by source A. Fast Fourier Transform. Define CH1, CH2, CH3 or CH4 as source A. Define CH1, CH2, CH3 or CH4 as source B. Invert the MATH waveform. Restore to original waveform display. User’s Guide for DS1000B series RIGOL Figure 2-17 Table 2-7 The Math menu (Page 2/2) Menu Reset User’s Guide for DS1000B Series Settings Comments The multifunctional knob ( ) adjusts the vertical position of the Math waveform. The multifunctional knob ( ) adjusts the vertical amplitude of the Math waveform. Reset the math waveform to vertical mid-point. 2-15 RIGOL 1. Using FFT function The FFT (Fast Fourier Transform) process converts a time-domain signal into its frequency components mathematically. FFT waveforms are useful in the following applications: Measuring harmonic content and distortion in systems Characterizing noise in DC power supplies Analyzing vibration Press MATH→Operate→FFT to enter FFT setting menu. Figure 2-18 Figure 2-19 Table 2-8 The FFT menu (Page 1/2) Menu Settings Comments Operate A+B A-B A×B FFT Add source A to source B. Subtract source B from source A. Multiply source B by source A. Fast Fourier Transform. Source CH1, CH2, CH3, CH4 Define CH1, CH2, CH3 or CH4 as FFT source. Window Rectangle Hanning Hamming Blackman Select window for FFT. Display Split Full screen Display FFT waveform on full screen. Table 2-9 The FFT menu (Page 2/2) Menu Settings Scale VRMS dBVRMS Reset 2-16 Display FFT waveform on half screen. comments The multifunctional knob ( ) adjusts the vertical position of Math The multifunctional knob ( ) adjusts the vertical amplitude of Math Set VRMS as vertical scale unit Set dBVRMS as vertical scale unit Reset the math waveform to vertical mid-point. User’s Guide for DS1000B series RIGOL Key points for FFT 1. 2. 3. Signals that have a DC component or offset can cause incorrect FFT waveform component magnitude values. To minimize the DC component, choose AC Coupling on the source signal. To reduce random noise and aliases components in repetitive or single-shot events, set the oscilloscope acquisition mode to Average. To display FFT waveforms with a large dynamic range, use the dBVRMS scale. The dBVRMS scale displays component magnitudes using a log scale. User’s Guide for DS1000B Series 2-17 RIGOL 2. Selecting an FFT Window DS1000B series oscilloscope provides four FFT windows. Each window is a trade-off between frequency resolution and amplitude accuracy. It depends on the desired measurement and the source signals characteristics to determine the window to use. Use the following guidelines to select the best window. DS1000B provides four FFT functions with different features, which are needed to be selected according to measuring waveform. Table 2-10 FFT Windows Window Features Best for measuring Best frequency resolution and worst amplitude accuracy. Transients or bursts, the signal levels before and after the event are nearly equal. Equal-amplitude sine waves with fixed frequencies. Broadband random noise with a relatively slow varying spectrum. Rectangle This is essentially the same as no window. Hanning Hamming Blackman 2-18 Better frequency resolution, poorer amplitude accuracy than Rectangular. Sine, periodic, and narrow-band random noise. Hamming has slightly better frequency resolution than Hanning. Transients or bursts where the signal levels before and after the events are significantly different. Best amplitude accuracy, worst frequency resolution. Single frequency waveforms, to find higher order harmonics. User’s Guide for DS1000B series RIGOL Term Explanations FFT Resolution: The FFT resolution is the quotient between sampling rate and the number of FFT points. With a fixed FFT points, the lower sampling rate, the better the resolution. Nyquist Frequency: The highest frequency that any real-time digitizing oscilloscope can acquire without aliasing. It’s normally half of the sample rate. This frequency is called the Nyquist frequency. Frequency above the Nyquist frequency will be under sampled, causing a situation known as aliasing. User’s Guide for DS1000B Series 2-19 RIGOL REF Function Reference Waveforms are saved waveforms to be selected for display. The reference function will be available after saving the selected waveform to non-volatile memory. During the actual measurement process, you can use DS1000B series digital oscilloscope to observe the waveforms of correlative components. It will help you to determine the cause of malfunction when you compare the measured waveform with the reference waveform. The method is particularly useful under the circumstance of having reference waveforms. Press REF button to display the Reference waveform menu. Figure 2-20 Table 2-11 REF menu when using internal memory (Page 1/3) Menu Channel 2-20 Settings REF 1 REF 2 REF 3 REF 4 1 2 3 4 Comments Turn on or turn off one to four REF channels Select the current REF channel which is optional from REF1 to REF4. (According to the available channel, for example, if only REF1 is turned on, then only REF1 can be chosen as the current channel.) Current REF REF REF REF Source CH1 CH2 CH3 CH4 MATH Select CH1, CH2, CH3, CH4, and MATH as the source channel whose input waveforms will be compared with the reference waveforms. location Internal external Select memory location in scope. Select memory location out scope. User’s Guide for DS1000B series RIGOL Figure 2-21 Table 2-12 REF menu when using internal/external memory (Page 2/3) Menu Settings Comments Save REF waveform to outer memory location. Save The multifunctional knob ( the vertical position of REF ) adjusts The multifunctional knob ( ) adjusts the vertical amplitude of REF Figure 2-22 Table 2-13 REF menu when using internal memory (Page 3/3) Menu Figure 2-23 settings comments Reset Reset REF waveform. Imp./Exp. Go to import menu (see table 2-19). Table 2-14 REF menu when using external memory (Page 3/3) Menu settings comments Reset Reset REF waveform. Import Go to import menu (see table 2-19). User’s Guide for DS1000B Series 2-21 RIGOL 1. Import and Export Switch to external memory and select Internal location. Then, press REF →Imp. /Exp. and enter the following interface. Figure 2-24 Import and export interface Figure 2-25 2-22 Table 2-15 Imp. /Exp. Menu Menu Settings Comments Explorer Path Directory File Switch to Path, directory or file. Export Export the REF file from internal memory to external memory (see table 2-16). Import Import the REF file to internal memory. Delete File Delete file. User’s Guide for DS1000B series RIGOL 2. Export Switch to external memory and select Internal location. Then, press REF→Imp. /Exp.→ Export and go to the following interface. Figure 2-26 Export interface Figure 2-27 Table 2-16 The Export menu Menu Settings Comments Move the input focus point of files’ name up and down. Move the focus point to next location. To delete chosen letter. Save User’s Guide for DS1000B Series Execute the operation. 2-23 RIGOL 3. Save to External Memory Switch to external memory and select External location. Then, press REF→Save and enter the following interface. Figure 2-28 Save interface Figure 2-29 2-24 Table 2-17 The Save menu Menu Settings Comments Explorer Path Directories Files Switch among Path, Directories and Files. New File (Folder) Set up new file in Path and File. Set up new folder in directory. Delete File (Folder) Delete chosen file (Folder). User’s Guide for DS1000B series RIGOL 4. New File (or New Folder) Switch to external memory and select External location. Then, press REF→Save→New File (or New Folder) and go to the following interface. File Name Input Pane Switch Chinese and English Switch Capital On or Off Figure 2-30 File name in English inputting interface Figure 2-31 Table 2-18 The New File menu Menu Settings Comments Move the focus point of file name up and down. Move the focus point to the next location. To delete chosen letter. Save User’s Guide for DS1000B Series Execute the saving operation. 2-25 RIGOL 5. Import Switch to external memory and select External location. Then, press REF→Import and enter the following interface. Figure 2-32 Import interface Figure 2-33 Table 2-19 The Import menu Menu Settings Comments Explorer Path Directories Files Switch among Path, Directories and Files. Import 2-26 Import the REF file into internal memory. User’s Guide for DS1000B series RIGOL 6. Display a Reference Waveform Figure 2-34 Reference waveform display Operation introductions: 1. 2. Press REF button to show the reference waveform menu. Press soft button 3 to select the reference channel: CH1, CH2, CH3, CH4 or MATH. 3. Turn vertical and vertical to adjust the REF waveform to a suitable position. Press soft button No.4 to select the save location of REF waveform. Enter to REF menu (Page2/3) Press soft button No.2 to save the waveform as REF. 4. 5. NOTE: The Reference function is not available in X-Y mode. User’s Guide for DS1000B Series 2-27 RIGOL To Set up the Horizontal System Press MENU button to enter the horizontal setting system. Figure 2-35 Table 2-20 The Horizontal menu Menu Settings Comments Delayed ON OFF Turn on the Delayed Scan mode. Turn off the Delayed Scan mode. ScreenCenter TimeExpand Trigger User Y-T Time Base X-Y Roll[1] Trig-Offset Reset The waveform expands or compresses horizontally around the center of the screen when the horizontal time base is changed. The waveform expands or compresses horizontally around the trigger point when the horizontal time base is changed. The waveform expands or compresses horizontally around the user-defined reference position when the horizontal time base is changed. Show the relative relation between vertical voltage and horizontal time. Show CH1 amplitude value at X axis; show CH2 amplitude value at Y axis. In Roll Mode, the waveform display updates from right to left. Adjust the trigger position to the center of the memory. NOTE: [1] In Roll mode, both the horizontal knob and trigger control are inoperative. Once the oscilloscope is set to Roll mode, the time base should be 50ms or slower. 2-28 User’s Guide for DS1000B series RIGOL Term Explanations Slow Scan Mode: This mode is available when the horizontal time base is set to 50ms or slower. In this mode, the oscilloscope acquires sufficient data for the left part to the trigger point, then wait for trigger, when trigger occurs, it continue to draw the rest part from the trigger point to the end of the right side. When choosing this mode to view low frequency signals, it is recommended that the channel coupling be set as DC. User’s Guide for DS1000B Series 2-29 RIGOL Knobs Explanation The horizontal controls change the horizontal scale and position of waveforms. The horizontal center of the screen is the time reference for waveforms. Changing the horizontal scale causes the waveform to be expanded or compressed with respect to the screen center. Horizontal position changes the displayed waveform position, relative to the trigger point. 1. The horizontal knob adjusts the horizontal position of all channels (including Math) waveforms. The resolution of this control varies with the time base. Pressing this button clears the trigger offset and moves the trigger point to the horizontal center of the screen. 2. Use to select the horizontal time/div (scale factor) for the main or the Delayed scan time base. When Delayed Scan is enabled, it changes the width of the window zone by changing the Delayed Scan time base. 2-30 User’s Guide for DS1000B series RIGOL Delayed Scan The Delayed Scan is a magnified portion of the main waveform window. Use Delayed Scan to locate and horizontally expand part of the main waveform window for a more detailed (higher horizontal resolution) analysis of signal. The Delayed Scan time base setting cannot be set slower than the Main time base setting. Press MENU→Delayed→ON, or press horizontal scan function. See the waveform below. knob to turn on delayed Waveform to be Horizontally Expanded Time Base of Delayed Scan Expanded Waveform in Horizontal Figure 2-36 Delayed scan windows The screen will be split into two parts. The upper half displays the main waveform window and the lower half displays an expanded portion of the main waveform window. This expanded portion of the main window is called the Delayed Scan window. Two blocks shaded at the upper half; the un-shaded portion is expanded in the lower half. The horizontal and knobs control the size and position of the Delayed Scan. The value at top of the screen is the main time base and the value on the center bottom means the Delayed Scan time base. User’s Guide for DS1000B Series 2-31 RIGOL X-Y Format This format is useful for studying phase relationships between CH1 and ch2 (CH3 and CH4 can’t be used).CH1 in the horizontal axis(X) and CH2 in the vertical axis(Y), the oscilloscope uses a none-trigger acquisition mode, data is displayed as dots. Press MENU→Time Base→X-Y to enter X-Y mode. Figure 2-37 X-Y display format The oscilloscope can acquire waveforms with any sampling rate in Y-T mode (up to 2GSa/s for single channel or half channel [1]). But in X-Y mode, up to 1GSa/s can be used and the default is 250MSa/s. Generally, the lower the sample rate is, the better the Lissajous graphic will be. NOTE [1]: Half channel indicates selecting one of the channels in CH1 and CH2, or in CH3 and CH4. The 2-32 following modes or functions will not work in X-Y format. Cursor measurement (Track and Auto modes) Pass/Fail Function REF and MATH Operations Delayed Scan Mode Vector Display Mode Horizontal knob Trigger Controls User’s Guide for DS1000B series RIGOL To Set up the Trigger System The trigger determines when the oscilloscope starts to acquire data and display a waveform. When a trigger is set up properly, it can convert unstable displays or blank screens into meaningful waveforms. When the oscilloscope starts to acquire a waveform, it collects enough data so that it can draw the waveform to the left of the trigger point. The oscilloscope continues to acquire data while waiting for the trigger condition to occur. After it detects a trigger, the oscilloscope continues to acquire enough data so that it can draw the waveform to the right of the trigger point. Press MENU button to enter trigger system setting interface. Figure 2-38 Trigger system interface DS1000B provides five trigger modes: Edge, Pulse, Video, Pattern and Alternative. Edge: An edge trigger occurs when the trigger input passes through a specified voltage level in the specified slope direction. Pulse: Use this trigger mode to catch pulses with certain pulse width. Video: Use video trigger mode on fields or lines for standard video signals. Pattern: Recognising trigger by searching specified code. Alternative: Trigger on non-synchronized signals. User’s Guide for DS1000B Series 2-33 RIGOL Edge Trigger An edge trigger determines whether the oscilloscope finds the trigger point on the rising or the falling edge of a signal. Select Edge trigger Mode to trigger on Rising edge, falling edge or rising & falling edge. Press MENU→Mode→Edge to enter the following menu. Figure 2-39 Table 2-21 The Trigger menu Menu Settings Comments Source CH1 CH2 CH3 CH4 EXT EXT/5 Select CH1 as trigger source. Select CH2 as trigger source. Select CH3 as trigger source. Select CH4 as trigger source. Select EXT TRIG as trigger source. Select attenuated EXT TRIG/5 as trigger source. Select power line as trigger source. AC Line Slope Sweep Set up 2-34 Trigger on rising edge. Trigger on falling edge. Trigger on both ring & falling edge. Auto Normal Single Acquire waveform even no trigger occurred. Acquire waveform when trigger occurred. When trigger occurs, acquire one waveform then stop. To go to Set Up menu, see table 2-34 User’s Guide for DS1000B series RIGOL Pulse Width Trigger Pulse trigger occurs according to the width of pulse. The abnormal signals can be detected through setting up the pulse width condition. Press MENU→Mode→Pulse to enter the following menu. Figure 2-40 Table 2-22 The Trigger menu (Page 1/2) Menu Source Settings Comments CH1 CH2 CH3 CH4 EXT EXT/5 Select CH1 as trigger source. Select CH2 as trigger source. Select CH3 as trigger source Select CH4 as trigger source l Select EXT TRIG as trigger source Select attenuated EXT TRIG/5 as trigger source. Set Set Set Set Set Set When Settings Figure 2-41 <Width> Pulse Pulse Pulse Pulse Pulse Pulse width width width width width width as as as as as as “+pulse width less than” “+pulse width more than” “+pulse width equal to” “-pulse width less than” “-pulse width more than” “-pulse width equal to” To set required pulse width. Table 2-23 The Trigger menu (Page 2/2) Menu Sweep Settings Comments Auto Normal Single Acquire waveform even no trigger occurred. Acquire waveform when trigger occurred. When trigger occurs, acquire one waveform and then stop. Set Up To go to Set Up menu, see table 2-34. NOTE: The Pulse width adjust range is 20ns~10s. When the condition is met, it will trigger and acquire the waveform. User’s Guide for DS1000B Series 2-35 RIGOL Video Trigger Choose video trigger to trigger on fields or lines of NTSC, PAL, or SECAM standard video signals. Trigger coupling preset to DC. Press MENU→Mode→Video to enter the following menu. Figure 2-42 Table 2-24 The Video Trigger menu (Page 1/2) Menu Settings Comments Source CH1 CH2 CH3 CH4 EXT EXT/5 Selects CH1 as trigger source. Selects CH2 as trigger source. Selects CH3 as trigger source. Selects CH4 as trigger source. Select EXT TRIG as trigger source. Select EXT TRIG/5 as trigger source. Polarity [1] Sync Normal Trigger on the negative edge of the sync polarity pulse Inverted Trigger on the positive edge of the sync pulse polarity All Lines Line Num Odd field Even field Trigger on all lines. Trigger on a specified line. Select to trigger on odd field. Select to trigger on even field. Note: [1] Normal polarity is applicable to signal with negative horizontal sync pulse; Inverted polarity is applicable to signal with positive horizontal sync pulse. 2-36 User’s Guide for DS1000B series RIGOL Figure 2-43 Table 2-25 The Video Trigger menu (Line Num, Page 2/2) Menu Line Num Standard Settings < Line sync > PAL/SECM NTSC Auto Sweep Normal Single Set Up Comments The range is from No.1 to No.525 when NTSC video standard is used and from No.1 to No.625 when PAL/SECAM video standard is used. Select Video standard. Acquire waveform even no trigger occurred. Acquire waveform when trigger occurred. When trigger occurs, acquire one waveform and then stop. To go to set up menu, see Table 2-36. Figure 2-44 Table 2-26 The Video Trigger menu (All lines, Odd field and Even field, Page2/2) Menu Settings Comments Standard PAL/SECAM NTSC Select Video standard. Auto Sweep Normal Single Set Up User’s Guide for DS1000B Series Acquire waveform even no trigger occurred. Acquire waveform when trigger occurred. When trigger occurs, acquire one waveform and then stop. To go to set up menu, see Table 2-36. 2-37 RIGOL Select “Line Synchronization”: Figure 2-45 Video Trigger: Line Synchronization 2-38 Select “Filed Synchronization”: Figure 2-46 Video Trigger: Field Synchronization User’s Guide for DS1000B series RIGOL Pattern Trigger Pattern trigger recognises the trigger condition through inspecting the code preset which means the logic values or the logic combination.Every channel has its own logic value,such as,logic high value,logic low value,and the neglect value. Press MENU→Mode→Pattern to enter the following menu. Figure 2-47 Table 2-27 The Pattern Trigger menu Menu Channel Settings Comments CH1 CH2 CH3 CH4 EXT EXT/5 To select CH1 as trigger source To select CH2 as trigger source To select CH3 as trigger source To select CH4 as trigger source To set EXT as trigger source To set EXT/5 as trigger source to expand trigger level range. To set the code of the selected channel as logic high value. To set the code of the selected channel as logic low value. To set the code of the selected channel as neglect value. To specify trigger to the rising edge of signal To specify trigger to the falling edge of signal Acquire waveform even no trigger occurred. Acquire waveform when trigger occurred. When trigger occurs, acquire one waveform then stop. H L Code X Auto Sweep Normal Single Set up User’s Guide for DS1000B Series To go to set up menu, see Table 2-34. 2-39 RIGOL Figure 2-48 Pattern trigger: set code as falling edge 2-40 User’s Guide for DS1000B series RIGOL Alternative Trigger When alternative trigger is on, the trigger sources come from two vertical channels. This mode can be used to observe two non-related signals. You can choose two different trigger modes for the two vertical channels. The options are as follows: Edge, Pulse and video. The info of the trigger level of the two channels will be displayed on the upper-right of the screen. Press MENU→Mode→Alternative to enter the following menu. Figure 2-49 Table 2-28 The Alternative trigger menu (Page 1/2 Trigger Type: Edge) Menu Settings Comments Alt Channel CH1-CH2 CH1-CH3 CH1-CH4 CH2-CH3 CH2-CH4 CH3-CH4 To specify the current alternative trigger channels as any two channels selected form CH1, CH2, CH3, CH4. select CH1, CH2 CH3, CH4 To select vertical channel among CH1, CH2, CH3, CH4 in alternative trigger mode so as to configure further settings. Type Edge Pulse Video Choose trigger type for the current channel. Figure 2-50 Table 2-29 The Alternative trigger menu (Page 2/2 Trigger Type: Edge) Menu settings comments Edge type Trigger on rising edge. Trigger on falling edge. Set up To go to set up menu. See Table 2-34 User’s Guide for DS1000B Series 2-41 RIGOL Figure 2-51 Table 2-30 The Alternative trigger menu (Page 1/2 Trigger Type: Pulse) Menu Settings Alt Channel CH1-CH2 CH1-CH3 CH1-CH4 CH2-CH3 CH2-CH4 CH3-CH4 Comments To specify the current alternative trigger channels as any two channels selected form CH1, CH2, CH3, CH4. select CH1, CH2, CH3, CH4 To select vertical channel among CH1, CH2, CH3, CH4 in alternative trigger mode so as to configure further settings. type Edge trigger Pulse trigger Video trigger Select trigger channel. type for current Figure 2-52 Table 2-31 The Alternative trigger menu (Page 2/2 Trigger Type: Pulse) Menu Settings Set Pulse width as “+pulse width less than” Set Pulse width as “+pulse width more than” Set Pulse width as “+pulse width equal to” Set Pulse width as “-pulse width less than” Set Pulse width as “-pulse width more than” Set Pulse width as “-pulse width equal to” When Settings Set Up 2-42 Comments <Pulse width > To set up width value of the pulse. To go to set up menu. See Table 2-34. User’s Guide for DS1000B series RIGOL Figure 2-53 Table 2-32 The Alternative trigger menu (Page 1/2 Trigger Type: Video) Menu Settings Comments Alt Channel CH1-CH2 CH1-CH3 CH1-CH4 CH2-CH3 CH2-CH4 CH3-CH4 To specify the current alternative trigger channels as any two channels selected form CH1, CH2, CH3, CH4. select CH1, CH2, CH3, CH4 To select vertical channel among CH1, CH2, CH3, CH4 in alternative trigger mode so as to configure further settings. Type Edge trigger Pulse trigger Video trigger To select trigger type for current channel. Figure 2-54 Table 2-33 The Alternative trigger menu (Page 2/2 Trigger Mode: Video) Menu Polarity [1] Settings Normal polarity Inverted polarity Comments Trigger on the negative edge of the sync pulse Trigger on the positive edge of the sync pulse Sync ALL lines Line Num Odd field Even field Trigger on all lines. Trigger on a specified line. Select to trigger on odd field. Select to trigger on even field. Standard PAL/SECM NTSC Select Video standard. Set Up To go to set up menu, see Table 2-36. Note: [1] Normal polarity is applicable to signal with negative horizontal sync pulse; Inverted polarity is applicable to signal with positive horizontal sync pulse. User’s Guide for DS1000B Series 2-43 RIGOL Trigger Settings Set up different trigger settings according to different trigger modes. In Edge, Pulse and Pattern trigger modes. You need to set up coupling, sensitivity and trigger holdoff; in video trigger mode, to set up sensitivity and holdoff; in alternate trigger, different trigger types have different setting options. Figure 2-55 Table 2-34 The Trigger Set Up menu (Page 1/2 Settings for Edge, Pulse and Pattern Triggers) Menu Coupling HF reject Sensitivity Holdoff 2-44 Settings Comments DC AC LF Reject Allow all signals pass. Block DC signals. Reject DC and low frequency signals. ON Passes high frequency component. Blocks high frequency component, passes low frequency component. oFF <Sensitivity Setting> <Holdoff Setting> Set trigger sensitivity between 0.1div to 1.00div. Set time slot before another trigger event between 100ns to 1.5s. User’s Guide for DS1000B series RIGOL Figure 2-56 Table 2-35 Page 2/2 Settings for Edge, Pulse and Pattern Triggers Menu Holdoff Figure 2-57 Settings Reset comments Reset Holdoff time to 500ns. Table 2-36 Settings for Video Trigger Menu Sensitivity Holdoff Holdoff User’s Guide for DS1000B Series Settings Comments <Sensitivity Setting> Set trigger sensitivity between 0.1div to 1.00div. <Holdoff Setting> Reset Set time slot before another trigger event between 100ns to 1.5s. Reset Holdoff time to 500ns. 2-45 RIGOL Trigger Holdoff You can use trigger Holdoff to stabilize a complex waveform, such as a pulse sequence. Holdoff time is the oscilloscope’s waiting period before starting a new trigger. During Holdoff, oscilloscope will not trigger until Holdoff ends. For instance: To trigger on the first pulse on a group of them, users can set the holdoff time to Pulse cluster width. Trigger Position Trigger Holdoff Time of Holdoff Figure 2-58 Trigger holdoff Operation Explanations: 1. Press the MENU button of the trigger control system to display the Menu. 2. Press Set Up key to display trigger set up menu. 3. Turn the multi function knob ( ) to change Holdoff time until waveform is stable. 4. Press Trigger Holdoff→Reset to reset the Holdoff time to its default value (500ns). 2-46 User’s Guide for DS1000B series RIGOL Trigger Terms Explanation 1. Trigger Source: Trigger occurs from several sources: Input channels (CH1, CH2, CH3, CH4), AC Line, Ext, Ext/5. CH1, CH2, CH3, CH4: It is the most commonly used trigger source. The channel works when it is selected as a trigger source whatever displayed. Ext Trig: The instrument can be triggered from an external source while acquiring data from CH1, CH2, CH3, and CH4. For example, be a trigger source with an external clock or a signal from another part of the test circuit. The Ext, Ext/5 trigger sources use an external trigger signal connected to the EXT TRIG connector. Ext uses the signal directly; it has a trigger level range of -0.6 V to +0.6 V. The EXT/5 trigger source attenuates the signal by 5X, which extends the trigger level range to -3V to +3 V allowing the oscilloscope to trigger on a larger signal. AC Line: AC power can be used to display signals related to the power line frequency, such as lighting equipment and power supply devices. The oscilloscope gets triggered on its AC power input, but an AC trigger signal is not required. 2. Trigger Mode: The trigger mode determines how the oscilloscope behaves in the absence of a trigger event. The oscilloscope provides three trigger modes: Auto, Normal, and Single. Auto: This sweep mode allows the oscilloscope to acquire waveforms even when it does not detect a trigger condition. If no trigger condition occurs while the oscilloscope is waiting for a specific period (as determined by the time-base setting), it will force itself to trigger. When forcing invalid triggers, the oscilloscope cannot synchronize the waveform, and the waveform seems to roll across the display. If valid triggers occur, the User’s Guide for DS1000B Series 2-47 RIGOL display becomes stable on the screen. Any factor results in the instability of waveforms can be detected by Auto Trigger, such as the output of Power supply. NOTE: When horizontal control is set under 50 ms/div, Auto mode allows the oscilloscope not to capture trigger signal. Normal: The Normal mode allows the oscilloscope to acquire a waveform only when it is triggered. If no trigger occurs, the oscilloscope keeps waiting, and the previous waveform will remain on the display. Single: In Single mode, after pressing the Single key, the oscilloscope waits for trigger. While the trigger occurs, the oscilloscope acquires one waveform then stop. 3. Coupling: Trigger coupling determines which signal component passing to the trigger circuit. Coupling types include AC, DC, LF Reject and HF Reject. AC: AC coupling blocks DC components and attenuate signal lower than 10 Hz. DC: DC coupling passes both AC and DC components. LF Reject: LF Reject coupling blocks DC component, and attenuates all signal with a frequency lower than 10 kHz. HF Reject: HF Reject coupling attenuates all signals with a frequency higher than 100 kHz. 4. Pre-trigger/delayed trigger: The data is collected before and after trigger. The trigger position is typically set at the horizontal center of the screen. In the full-screen display the 6div data of pre-trigger and delayed trigger can be surveyed. More data (14div) of pre-trigger and 1s delayed trigger can be surveyed by adjusting the horizontal knob. This feature is very useful to study the events that led up to the trigger point. Everything on the right of the trigger point is called post-trigger information. Delay range (pre-trigger and post-trigger information) depends on the sweep speed selected. 2-48 User’s Guide for DS1000B series RIGOL 5. Adjustable trigger sensitivity To avoid the influence of noise from the physical world, and get the stable trigger, the trigger circuit has adopted Stickiness. In DS1000B series, the stickiness is adjustable from 0.1div-1.0div, which means when it sets to 1.0div; the trigger circuit will not affect any signal with peak-peak amplitude less than 1.0div, so as to avoid the influence of the noise. User’s Guide for DS1000B Series 2-49 RIGOL To Set up the Sampling System Figure 2-59 shows, the Acquire button at the MENU of the front panel. Acquire Setup Button Figure 2-59 The Acquire setup button Press Acquire button, the interface menu shows as follows: Figure 2-60 Table 2-37 The Acquire menu Menu Settings Comments Acquisition Normal Average Peak Detect Normal Acquisition mode. Average Acquisition mode. Peak Detect Acquisition mode. Averages[1] 2 to 256 Set average times by N-th power of 2 from 2 to 256. Sampling Real-Time Equ-Time Real-time sampling mode. Equivalent sampling mode. Sinx/x[2] ON OFF Set the interpolation as Sinx/x. Set the interpolation as linearity. Sa Rate[3] Display sampling rate. NOTES: [1] This function appears when acquisition as “Average”. [2] This function appears when sampling as “Real-Time”. [3] Sample rate channels will be displayed respectively in alternative trigger mode. 2-50 User’s Guide for DS1000B series RIGOL The waveform displayed on the screen will change in conjunction with the setting of Acquire menu. To reduce the displayed random noise, select the Average Acquisition. This mode would make the screen refresh slower. To Avoid signal aliasing, select Peak Detect Acquisition. Select Real-time acquisition to observe the single-shot or pulse signals. Select Equ-Time to observe high frequency repetitive signals. Figure 2-61 Signal that contains noise, and without average sampling Figure 2-62 Display signal after average sampling User’s Guide for DS1000B Series 2-51 RIGOL Figure 2-63 Adopt Normal acquisition Figure 2-64 Adopt peak detect acquisition, signal contains envelope Key points When the scope is acquiring waveforms, the Stop Acquisition: waveforms is in a live status; when acquisition is stopped, frozen waveform will be displayed, the position and scale can still be adjusted by vertical control and horizontal control. 2-52 User’s Guide for DS1000B series RIGOL Key Points: Real-time Sampling: DS1000B has Real-time sampling rate up to 2GSa/s. At the time base 20ns or faster, the oscilloscopes use the sine(x)/x interpolation to expand the horizontal time base. Equivalent sampling: Known as Repetitive sampling to get up to 20ps of horizontal resolution (equivalent 50Gsa/s). This mode is good for observing repetitive signals, and it is not recommended for single-shot or pulse. Normal Acquisition: Oscilloscope acquires signal by equal time interval. Average Acquisition: Apply averaging to your signal to remove uncorrelated noise and improve measurement accuracy. Reduces random or uncorrelated noise in the signal display. The averaged waveform is a running average over a specified number of acquisitions from 2 to 256. Peak Detect: Peak Detect mode captures the maximum and minimum values of a signal, and finds highest and lowest record points over many acquisitions. User’s Guide for DS1000B Series 2-53 RIGOL To Set up the Display System The menu button for the display system on the front panel is shown in the following figure. Display Setup Button Figure 2-65 The display setup button Press the Display button, the interface menu for settings shows as follows. Figure 2-66 Table 2-38 The Display menu (Page 1/3) Menu Setting Comments Type Vectors Dots Display waveforms as vectors. Display waveforms as dots. Clear all existing waveforms from screen. Clear Infinite Persist OFF Intensity 2-54 <waveform intensity> The sample points remain displayed until turn the persistence “OFF”. Turn off the persistence function. Set up waveform intensity (0% to 100%). User’s Guide for DS1000B series RIGOL Figure 2-67 Table 2-39 The Display menu (Page 2/3) Menu Settings Comments Grading ON OFF The waveform is displayed in multiple levels of pixel intensity. Display grids and coordinates on the screen. Turn off the grids. Turn off the grids and coordinates. Grid Menu Display Figure 2-68 1s 2s 5s 10s 20s Infinite Set the time before menu fades away. The menu will be hidden after the set time of last button pressing. Table 2-40 The Display menu (Page 3/3) Menu Settings Comments GridBright <grid Set up grid brightness (0% to 100%). brightness> Screen Normal Inverted To show the last acquired waveform when the acquisition is stopped. To show the accumulated acquired waveforms when the acquisition is stopped. Screen persist Skin User’s Guide for DS1000B Series Set to normal mode. Set to invert color display mode. Classical Modern Tradition Succinct To set the display screen of the oscilloscope 2-55 RIGOL Term Explanations Refresh rate: It is an important performance of digital oscilloscopes. It means the number of display refreshing per second and it will affect the ability to observe signal. Adjusting waveform intensity Default setup of multi-function knob ( 2-56 ) is adjusting waveform intensity. User’s Guide for DS1000B series RIGOL To Store and Recall Figure 2-69 shows the menu button for the storage system on the front panel. Storage Setup Button Figure 2-69 The storage setup button Press the Storage button, the interface menu for settings shows as follows. Figure 2-70 Table 2-41 The Storage menu (Waveform and Setups storage) Menu Settings Waveform Storage [1] Comments [2] Setups 8-Bitmap 24-Bitmap PNG CSV Factory Create, Save, Recall, Delete waveform files. Create, Save, Recall, Delete setups files. Create or delete 8bits bitmap files. Create or delete 24bits bitmap files. Create or delete PNG format files. Create or delete CSV files. Recall factory setups. Internal Go to menu for internal memory operation (see Table 2-46). External Go to menu for external memory operation (see Table 2-47). Disk Mgr. Go to disk manage menu (see Table 2-48). NOTES: [1] The waveform and setups files in internal memory can be created, saved, recalled and deleted. While, the waveform, setups, 8-bitmap, 24-bitmap, PNG, CSV files can be created and deleted. [2] Both waveforms and status settings could be saved in “Waveform Storage”. User’s Guide for DS1000B Series 2-57 RIGOL Figure 2-71 Table 2-42 The Storage menu (Bitmap storage) Menu Storage Para Save Figure 2-72 8-Bitmap 24-Bitmap ON OFF Comments Create or delete 8bits Bitmap files. Create or delete 24bits Bitmap files. Save the current oscilloscope settings in different format with the same file name. External Go to menu for external memory operation (see Table 2-47). Disk Mgr. Go to disk manage menu (see Table 2-48). Table 2-43 The Storage menu (PNG storage) Menu Settings Comments Storage PNG Create or delete PNG format files. ON Save the current oscilloscope settings in different format with the same file name. Para Save 2-58 Settings OFF External Go to menu for external memory operation (see Table 2-47). Disk Mana. Go to disk manage menu (see Table 2-48). User’s Guide for DS1000B series RIGOL Figure 2-73 Table 2-44 The Storage menu (CSV storage) Menu Settings Comments Storage CSV Create or delete CSV files. Displayed Save currently displayed waveform data to CSV file. Save the whole waveform data in memory to CSV file. Save the current oscilloscope settings in different format with the same file name. Go to menu for external memory operation (see Table 2-47). Go to disk manage menu (see Table 2-48). Data Depth Para Save Maximum ON OFF External Disk Mana. Figure 2-74 Table 2-45 The Storage menu (Factory storage) Menu Storage Settings Factory Comments Recall factory setups. Recall Recall factory setups or files. Disk Mana. Go to disk manage menu (see Table 2-48). User’s Guide for DS1000B Series 2-59 RIGOL Internal Memory Press Storage→Internal to go to the following menu. Figure 2-75 Table 2-46 The Memory menu Menu Settings Comments Internal Int_00 (S) Int_01 (S) . . Int_09 (N) Set up the location of files in internal memory among Int_00 to Int_09. Thereinto, S in brackets indicates the location has storage file, N indicates has not. Recall Recall waveform files and setup files from the internal memory location. Save Save waveform files and setup files to the internal memory location. Delete File Delete selected files. NOTE: To ensure the setups being saved properly, only after the settings are changed for more than 5 seconds can the user turn off the instrument. The oscilloscope can store 10 settings permanently and can restore at anytime. 2-60 User’s Guide for DS1000B series RIGOL External Memory Press Storage→ External to go to the following interface. Path Back to Previous Folder File Current Folder File Info. Figure 2-76 External memory interface Figure 2-77 Table 2-47 The Memory menu Menu Settings Comments Explorer Path Directories Files Switch among Path, Directory and File. New File (Folder) To create new file or folder.(see table 2-18) Delete File (Folder) Delete file (Folder). Recall Recall waveform and setup from USB flash device. User’s Guide for DS1000B Series 2-61 RIGOL U-disk Selection Figure 2-78 U-disk selection DS1000B series have two USB Host ports on the front and rear panel. When both ports were inserted USB flash drive, the screen will appear a U-disk selection interface as Figure 2-78. Turn the multifunction knob to choose the driver. The front one marked “F:” and the rear one “G:”. 2-62 User’s Guide for DS1000B series RIGOL Disk Management Press Storage→Disk Mgr.. Then go to the following menu. Figure 2-79 Figure 2-80 Table 2-48 The Disk Management menu (Page 1/2) Menu Settings Comments Explorer Path Directories Files Switch among Path, Directory and File. New folder To create new folder (same as new files, see table 2-18). Delete File Delete selected file. Recall Recall waveform, setup, recorded waveform, Pass/Fail file. Table 2-49 The Disk Management menu (Page 2/2) Menu Settings Comments Rename To rename a file (see Table 2-50). Disk info Display disk information. User’s Guide for DS1000B Series 2-63 RIGOL 1. Disk Information Press Storage →Disk Mgr. →Disk info to go to the disk information interface. Figure 2-81 Disk information interface 2. Rename Press Storage→Disk Mgr.→Rename to go to the following interface. Figure 2-82 Rename the file 2-64 User’s Guide for DS1000B series RIGOL Figure 2-83 Table 2-50 The Rename menu Menu Settings Comments To move the input focus point of file name up and down. To move the focus point to the next location. To delete chosen letter. OK Rename the file. Key point Factory: The oscilloscope has default settings and can be recalled at anytime by user. Memory location: Specify the memory location to save/recall the waveforms and setups. Recall: Recall saved waveforms, setups and default settings. Save: Save waveforms and setups. User’s Guide for DS1000B Series 2-65 RIGOL To Set up the Utility Figure 2-69 shows the menu button for the utility system on the front panel. System Function Setup Button Figure 2-84 The Utility setup button Press the Utility button to show the menu of the settings in the Utility system. Figure 2-85 Table 2-51 The Utility menu (Page 1/3) Menu Setting I/O setting Sound Counter Comments Setup I/O configuration. (ON) (OFF) OFF ON Turn beeper sound on/off. Turn off Frequency Counter. Turn on Frequency Counter. 简体中文 繁體中文 한국어 日本語 Language 2-66 English Deutsch Français Italiano Русский Português Espaňol Select languages. (More languages may be added in later firmware versions.) User’s Guide for DS1000B series RIGOL Figure 2-86 Table 2-52 The Utility menu (Page 2/3) Menu Figure 2-87 Settings Comments Pass/Fail Setup Pass/Fail test. Record Setup Waveform Recorder. Print set Setup printing. Table 2-53 The Utility menu (Page 3/3) Menu Settings Comments Self-Cal Execute Self-calibration. System Info Show the following information: Serial number, software version, installed module. Preference Go to preference menu. Date/Time Set the real date and time for system. Term Explanations Self-Cal: Oscilloscope will calibrate parameters of the vertical system (CH1, CH2, CH3, CH4 and Ext), horizontal system and trigger system to make sure that the oscilloscope can normally work under different environments. User’s Guide for DS1000B Series 2-67 RIGOL The I/O Setup Press Utility→IO Setting to go to the following menu. Figure 2-88 Table 2-54 The I/O Setup menu Menu Display Set network function, the local area network interface corresponds with the LXI standard. LAN Set USB Device GPIB# [1] Comments Auto Detect Computer PictBridge Set USB device function, connect USB interface to the needed device. 0~30 Set the GPIB address. NOTE: [1] If the instrument connection switches from “Computer” (or PictBridge printer) into PictBridge printer (or Computer), you should set the type of USB Device manually, to ensure a same connection type between instruments under use. 2-68 User’s Guide for DS1000B series RIGOL 1. LAN Setting Access the oscilloscope into Network, and press LAN Set to enter the setting interface, see figure below: Recall the LAN Initialize setting Move the focus up and down Move the focus left and right User-defined area Figure 2-89 LAN Setting interface The items under the black background in the setting area are available for current setting. Enter the desired parameter type or parameters for those items with the knob press down or rotating. Key Points There are three levels patterns of IP address from highness to lowness by Priority: DHCP, Auto IP and Manual IP. DHCP (Dynamic Host Configuration Protocol): assigning the IP address, subnet mask and the default gateway through the DHCP server in TCP/IP network on the basis of current configuration. Set the item ON to use the DHCP. Auto IP: generating an IP address within 169.254.0.1 and 169.254.255.254 in connection with a subnet mask automatically from the host. Disable the DHCP and set the Auto IP On before you use it. Manual IP: entering the IP address manually. If use this type, neither DHCP nor Auto IP should be “Off”. User’s Guide for DS1000B Series 2-69 RIGOL 2. Remote Control (1) By Web Page When the network configuration is completed, open the IE and enter the IP address of oscilloscope, it will enter the interface with relative information below. Figure 2-90 Remote control interface Click “Web Control” and set the corresponding parameters listed in the window below using the mouse. Figure 2-91 Remote control window 2-70 User’s Guide for DS1000B series RIGOL (2) By Commands DS1000B is a USB TMC (USB Test & Measurement Class) instrument, which could be controlled by commands on the basis of NI-VISA (NI-National Instrument, VISA-Virtual Instrument Software Architecture) or Agilent-VISA (for the details about commands, refer to the relative Programming Guide). USB or network is recommended for the communication between the instrument and a PC to integrate it into your testing system. The library related to VISA should be installed before using it. If both the NI-VISA and Agilent-VISA were installed in your computer, it would automatically identify the available VISA driver. Only one VISA driver is recommended to be used in a computer such as NI-VISA (visit www.ni.com to download). Here we show you NI-VISA as an example: Make a connection by network After the network is properly connected, the oscilloscope will automatically detect it and make configuration. In Measurement & Automation Explorer, select “Device and Interface” → “Create New”. Figure 2-92 Measurement & Automation Explorer interface Select “VISA TCP/IP Resource” in the dialog “Create New…” appeared. User’s Guide for DS1000B Series 2-71 RIGOL Figure 2-93 VISA TCP/IP Resource interface Click “Next” and select “Auto-detect of LAN Instrument”. Figure 2-94 Auto-detect of LAN Instrument interface 2-72 User’s Guide for DS1000B series RIGOL The software searching the available network device automatically. Figure 2-95 Search the network device interface Click “Finish” and you will see the oscilloscope that has been accessed to the network from the subdirectory “VISA TCP/IP Resource” under the main Explorer interface. Figure 2-96 Subdirectory of VISA TCP/IP Resource Choose a relative resource and open the communication testing panel to send commands and read the data. User’s Guide for DS1000B Series 2-73 RIGOL Figure 2-97 Communication testing dialog Make a connection by USB Connect the oscilloscope to a PC by using an USB data cable. Then, turn on the oscilloscope, at the moment, the computer will pop up a Hardware Installation wizard and please install the “USB Test and Measurement Device” according to the wizards. After installation, open Measurement & Automation Explorer and you will see the information about USB device that has been connected in the subdirectory. 2-74 User’s Guide for DS1000B series RIGOL Figure 2-98 Measurement & Automation Explorer interface Select the responding resource and open the VISA Test Panel to send commands and read data. Figure 2-99 Communication testing dialog User’s Guide for DS1000B Series 2-75 RIGOL Language The DS1000B series oscilloscopes have multi-language user menu, choose as your desire. Press Utility → Language to select the language. Press button No.4 until the desired language appears. Figure 2-100 Language selection screen 2-76 User’s Guide for DS1000B series RIGOL Pass/Fail The Pass/Fail function monitors changes of signals by comparing the input signal which is within the pre-defined mask. The testing results not only can be displayed on screen, but also can be alarmed by opening the system sound settings. Press Utility→Pass/Fail to go to the following menu. Figure 2-101 Table 2-55 The Pass/Fail menu (Page 1/2) Menu Setting Comments Enable Test ON OFF Turn on Pass/Fail test. Turn off Pass/Fail test. Source CH1, CH2, CH3, CH4 Select Pass/Fail test on CH1, CH2, CH3 or CH4. (RUN) Operate Msg display Figure 2-102 ■ (STOP) Pass/Fail test stopped, press to run. Pass/Fail test running, press to stop. ON OFF Turn on Pass/Fail information display. Turn off Pass/Fail information display. Table 2-56 The Pass/Fail menu (Page 2/2) Menu Settings Comments Fail Output when Fail condition detected. Output and beep when Fail condition detected. Output when Pass condition detected. Output and beep when Pass condition detected. Fail + Output Pass Pass+ Stop on Output Mask Setting User’s Guide for DS1000B Series ON OFF Stop test when output occur. Continue test when output occur. Go to mask setting menu. 2-77 RIGOL 1. Mask setting Press Utility→Pass/Fail→Mask Setting to go to the following menu. Figure 2-103 Table 2-57 The Mask setting menu (Page 1/2) Menu X Mask Y Mask Settings Comments <x div> Set horizontal clearance to the waveform (0.04div-4.00div). <y div> Set vertical clearance to the waveform (0.04div-4.00div). Create Mask Location Figure 2-104 Internal External Set the memory location of the mask files. Table 2-58 The Mask setting menu (Internal, Page 2/2) Menu 2-78 Create a test mask according to the above clearance. Settings Comments Save Store created test mask into internal memory. Recall Recall mask setting file from internal memory. Imp./Exp. Go to import/export menu (same as REF import/export menu. see table 2-15). User’s Guide for DS1000B series RIGOL Figure 2-105 Table 2-59 The Mask setting menu (External, Page 2/2) Menu 2. Settings Comments Save Go to save menu (same as REF save menu, see table 2-16). Recall Go to recall menu (see Table 2-63). Import Go to import menu. (Same as REF import menu, see table 2-18). Recall Press Utility→Pass/Fail→Mask Setting→Recall to recall the setting file from internal/external memory. Figure 2-106 Table 2-60 The Recall menu Menu Settings Comments Explorer Path Directories Files Switch among Path, Directory and File. Recall Recall the specified file from external memory. NOTE: Pass/Fail function is unavailable in X-Y mode. User’s Guide for DS1000B Series 2-79 RIGOL Waveform Recorder Waveform recorder records input waveforms from CH1, CH2, CH3 and CH4 with a maximum record length of 800 frames. This performance can also be activated by the Pass/Fail test, which makes this function especially useful to capture abnormal signals in long term without keeping an eye watching it. 1. 2. OFF: It will close all record functions. Record: To record waveform by selected time interval till the last frame. Press Utility→Record→Mode→Record to go to the following menu. Figure 2-107 Table 2-61 The Record menu (Page 1/2) Menu Settings Comments Mode OFF Record Play back Storage Select record mode. Select play back mode. Select storage mode. Turn off all recorder functions. Source CH1, CH2 CH3, CH4 P/F-OUT[1] Select record source channel. End Frame <1-800> (Run) Operate (Stop) Set number of record frames. Record stopped, press to Start recording. Press to stop recording. NOTE [1]: The waveform when Pass/Fail testing pass or fall. 2-80 User’s Guide for DS1000B series RIGOL Figure 2-108 Table 2-62 The Record menu (Page 2/2) Menu Interval 3. Settings Comments <1.00ms-1000s> Set time interval between record frames. Play Back: Play back the recorded waveforms. Figure 2-109 Table 2-63 The Play Back menu (Page 1/2) Menu Settings (Run) Operate (Stop) Figure 2-110 Comments Play stopped, press to Start playback. Press to stop playing. Play mode Set repeat play mode. Set single time play mode. Interval Set up interval value between frames. <1.00ms-20s> Table 2-64 The Play Back menu (Page 2/2) Menu Start Frame Current Frame End Frame User’s Guide for DS1000B Series Settings <1-800> <1-800> <1-800> Comments Set start frame. Select current frame to be played. Set End frame. 2-81 RIGOL Run/Stop Button The Run/Stop button can also replay or continue the waveform display. The Current Frame will go forward one frame by pressing Single button in Play back mode. 4. Storage: Store recorded waveforms in non-volatile memory according to the setup frames. Figure 2-111 Table 2-65 The Storage menu (Page 1/2) Menu Start Frame End Frame Location Figure 2-112 <1-800> <1-800> Internal external Comments Set first frame to be saved. Set last frame to be saved. Set up Store location. Table 2-66 The Storage menu (Internal location Page 2/2) Menu 2-82 Settings Settings Comments Save Save recorded waveform to internal memory location. Recall Recall recorded waveform from internal memory location. Imp./Exp. Go to import/export menu (Same as REF import/export menu. see table 2-14). User’s Guide for DS1000B series RIGOL Figure 2-113 Table 2-67 The Storage menu (External location Page 2/2) Menu Settings Comments Save Go to save menu (same as REF save menu. see table 2-160). recall Go to recall menu (see Table 2-63). Import Go to import menu. (Same as REF import menu, see table 2-18). User’s Guide for DS1000B Series 2-83 RIGOL Print Setting DS1000B series oscilloscopes support two print modes: “normal” and “PictBridge”. Please execute print operation according to the following steps: 1. Connect printer: If use PictBridge printer, please select “PictBridge” mode, and then connect the oscilloscopes regarded as “Device equipment” and printer via USB Device port on the rear panel. 40 US C Digital Oscilloscope 100-127V, 45-440Hz 100-240V, 45-65Hz LINE60WMAX Fuse: 250V, T2A RIGOL Technologies, Inc. LXI Class C Non Auto-MDIX LAN USB DEVICE USB HOST MADE IN CHINA Figure 2-114 PictBridge print If use Normal printer, please select “Normal” mode, and then connect the oscilloscopes regarded as “Host equipment” and printer via USB Host port on the front panel. Measure Acquire Storage Cursor Display Utility Single Auto Intensity SCALE POSITION QUICK Measure Help POSITION MENU Zoom Print POSITION POSITION POSITION Auto MODE Normal Single Zero CH1 Zero CH2 MATH SCALE SCALE Zero REF Zero CH3 CH4 SCALE SCALE LEVEL Zero MENU FORCE 50% CH1 CH2 CH3 CH4 // 8 300 V RMS Figure 2-115 Normal print 2-84 User’s Guide for DS1000B series RIGOL 2. To set up print parameters: Press Utility→Print set to into a setting menu. Please setup the printer type and the print mode as the case may be, or else the instrument will refuse printing if they can’t match well. Press PrintMod button, choose the print mode as Normal, and navigate into the following menu. Figure 2-116 Table 2-68 Print Set menu (Normal mode) Menu Settings Comments PrintMod Normal PictBridge Set the print mode as normal. Set the print mode as PictBridge. Print Execute the print operation. Inverted ON OFF Invert the color for print. Print original color. Palette Gray scale Color Set up the print color. Press PrintMod button, choose the print mode as PictBridge, and navigate into the following menu. Figure 2-117 Table 2-69 Print Set menu (PictBridge mode, Page 1/4) Menu Settings Comments PrintMod Normal PictBridge Set the print mode as normal. Set the print mode as PictBridge. Print Continue Execute the print operation. The menu will turn to “Continue” once appears recoverable error. To print continuously, press this button. Abort Abort the printing. Status Inquire about the current status of the printer. User’s Guide for DS1000B Series 2-85 RIGOL Figure 2-118 Table 2-70 Print setup menu (PictBridge mode, Page 2/4) Menu Paper size File type copies Figure 2-119 Settings Default, A2, A3, A4, A5, A6, B5 Default Exif/Jpeg Bmp 1~999 Print Quality Data print Settings Default Normal Draft fine Default ON OFF ON inverted 2-86 Select the paper size for printing. To specify the image type for printing as Exif/Jpeg or Bmp format. To set the print copies from 1to 999. Table 2-71 Print setup menu (PictBridge mode, Page 3/4) Menu Figure 2-120 Comments OFF Comments To specify the print quality. To turn on or off the print date. Turn on the inversion of printing color Turn off the inversion of printing color Table 2-72 Print setup menu (PictBridge mode, Page 4/4) Menu Settings Comments palette Grayscale Color To set the print image as grayscale or color. User’s Guide for DS1000B series RIGOL 3. Print: Make sure the Printer has been connected and the print settings are all ready before printing. Then, press Utility → Print or press operation, If you want to go on printing, please use the User’s Guide for DS1000B Series to execute print button. 2-87 RIGOL Self-Calibration The Self-Calibration adjusts the internal circuitry to get the best accuracy. Use this function to calibrate the vertical and horizontal systems. For maximum accuracy at any time, run this calibration if the ambient temperature changes by 5℃ or more. Before running this procedure, make sure that disconnect any probes or cables from all channel inputs, otherwise failure or damage to the oscilloscope may occur. Then, press the Utility → Self-Cal. Figure 2-121 The Self-Calibration menu NOTE: The oscilloscope must have been working or warm-up at least 30-minutes before running self-calibration to get best accuracy. 2-88 User’s Guide for DS1000B series RIGOL System Information Press Utility→System Info to view the system information, including Model, Serial Number, Software version and installed module. Figure 2-122 Information system interface User’s Guide for DS1000B Series 2-89 RIGOL Preference Press Utility→Preference to go to the following menu Figure 2-123 Table 2-73 The Preference menu Menu Display Comments Screen saver 1 min … 5 hour OFF Set up screen saver timer. Expand Ground Center Set up waveform vertical expand reference. Stickykey Turn the sticky status of CH1, CH2, CH3, CH4, MATH, REF, Trig.Lev. and Trig.Pos. on or off. Default Load Use the last setup in the next power on. Use the default setup of the system in the next power on. Last set Default Key Points Screen saver: This function extends the life of LCD backlighting system. Expand reference: When changing the volts/div. for channels, the signal expands or compresses around the signal ground level, or the center of the screen. When Center is selected, the waveform will expand or compress around the center of the display. When Ground is selected, the channel ground level will remain the same position on the display and waveform will zoom about the ground level. Sticky key: If sticky feature is turned ON, when adjusting positions (CH1, CH2, CH3, CH4, MATH, REF, Trig.Lev. and Trig.Pos.), the waveform will stop at zero position until next adjustment, for the ease of getting back to initial positions. 2-90 User’s Guide for DS1000B series RIGOL Date and Time DS1000B Series provide build-in system real-time date and time. Users can set the date and time as shown in the following figure. Time Display Figure 2-124 Date and time setting Figure 2-125 Table 2-74 Time setting menu Menu Display Settings OFF ON Comments Close time display Open time display Move up/down the setting focus Move left/right the setting focus OK User’s Guide for DS1000B Series Save the current settings 2-91 RIGOL To Measure Automatically The Measure button in the menu area activates the automatic measurement function. The instruction below shows the powerful measurement function of DS1000B series oscilloscopes. Auto Measurement Figure 2-126 The Measure setup button The oscilloscopes provide 22 auto measurements: Vpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time,Delay A B , Delay A B , Phase A B , Phase A B , +Width, -Width, +Duty, -Duty (10 voltage and 12 timing measurements). Press the Measure button to display the menu of the Automatic Measurements settings. Figure 2-127 2-92 Table 2-75 The Measure menu (Page 1/2) Menu Settings Comments Source CH1, CH2, CH3, CH4 Select CH1 or CH2 as source channel for measurement. Voltage Select measure voltage parameter. Time Select measure time parameter. Clear Clear measurement result on screen. User’s Guide for DS1000B series RIGOL Figure 2-128 Table 2-76 The Measure menu (Page 2/2) Menu Settings Display All OFF ON QuickMea Delay/Phase Setup User’s Guide for DS1000B Series Comments Turn off all measurements result. Turn on all measurements result. To specify three quick measure items which you can choose among the above 22 measurements. To configure the delay and phase channels, in order to measure delay and phase value relative to time measurement between any two vertical channels form CH1 to CH4. 2-93 RIGOL Quick Measurement Setup Press Measure→QuickMea button, go to the quick measure menu。 Figure 2-129 Table 2-77 Quick measure menu Menu Item1 Item2 Item3 2-94 Settings Comments To specify Item1, Item2 and Item3 respectively, each item can be chosen from 22 kinds of measure items. User’s Guide for DS1000B series RIGOL Delay/Phase Setup Press Measure→Delay/Phase Setup button, and go to the delay/phase setup menu. Figure 2-130 Table 2-78 The delay/phase setup menu. Menu Settings Delay A Delay B Phase A Phase B User’s Guide for DS1000B Series CH1 CH2 CH3 CH4 Comments To set CHA of Delay measurement as one of CH1,CH2,CH3,CH4 To set CHA of Phase measurement as one of CH1,CH2,CH3,CH4 2-95 RIGOL Voltage Measurements The DS1000B series oscilloscopes provide automatic voltage measurements including Vpp, Vmax, Vmin, Vavg, Vamp, Vrms, Vtop, Vbase, Overshoot and Preshoot. Figure 2-131 below shows a pulse with some of the voltage measurement points. Overshoot Vmax Vtop Vpp Vamp Vbase Vmin Preshoot Figure 2-131 Voltage parameters Vpp: Peak-to-Peak Voltage. Vmax: The maximum amplitude. The most positive peak voltage measured over the entire waveform. Vmin: The minimum amplitude. The most negative peak voltage measured over the entire waveform. Vamp: Voltage between Vtop and Vbase of a waveform Vtop: Voltage of the waveform’s flat top, useful for square/pulse waveforms. Vbase: Voltage of the waveform’s flat base, useful for square/pulse waveforms. Overshoot: Defined as (Vmax-Vtop)/Vamp, useful for square and pulse waveforms. Preshoot: Defined as (Vmin-Vbase)/Vamp, useful for square and pulse waveforms. Average: The arithmetic mean over the entire waveform. Vrms: The true Root Mean Square voltage over the entire waveform. 2-96 User’s Guide for DS1000B series RIGOL Press Measure→Voltage button, and go to the following menu. Figure 2-132 Table 2-79 The Voltage Measurement menu (Page 1/3) Menu Figure 2-133 Comments Vmax Measure maximum waveform. voltage of a Vmin Measure minimum waveform. voltage of a Vpp Measure Peak-to-Peak Voltage. Vtop Measure a flat top voltage of a square waveform. Table 2-80 The Voltage Measurement menu (Page 2/3) Menu Figure 2-134 Settings Settings Comments Vbase Measure a flat base voltage of a square waveform. Vamp Measure voltage between Top and Base. Vavg Measure average voltage of a waveform. Vrms Measure Root Mean Square Voltage of a waveform. Table 2-81 The Voltage Measurement menu (Page 3/3) Menu Settings Comments Overshoot Measure overshoots in percentage of an edge. Preshoot Measure preshoot in percentage of an edge. User’s Guide for DS1000B Series 2-97 RIGOL Time Measurements The DS1000B series oscilloscopes provide 12 kinds of timing parameters auto-measurements: Frequency, Period, Rise Time, Fall Time, +Width, -Width, Delay A→B , Delay A→B , +Duty and –Duty, Phase A→B ,Phase A→B . Figure 2-135 shows a pulse with some of the time measurement points. Fall Time Rise Time 90% 50% 10% +Width -Width Figure 2-135 Time parameters Rise Time: Time that the rising edge of the first pulse in the waveform takes to rise from 10% to 90% of its amplitude. Fall Time: Time that the falling edge of the first pulse in the waveform takes to fall from 90% to 10% of its amplitude. +Width: The width of the first positive pulse in 50% amplitude points. -Width: The width of the first negative pulse in the 50% amplitude points. Delay A→B : The time delays between the channel A and channel B at the rising edge. Delay A→B : The time delays between the channel A and channel B at the falling edge. Phase A→B : The phase between the channel A and channel B at the rising edge. Phase=(delay/source A period)×360° Phase A→B : The phase between the channel A and channel B at the falling edge. +Duty: +Duty Cycle, defined as +Width/Period -Duty: -Duty Cycle, defined as -Width/Period. 2-98 User’s Guide for DS1000B series RIGOL Press Measure→Time button, and go to the following menu Figure 2-136 Table 2-82 The Time Measurement menu (Page 1/3) Menu Figure 2-137 Comments Period Measure Period of a waveform. Freq Measure Frequency of a waveform. Rise time Measure Rise Time of a rising edge. Fall time Measure Fall Time of a falling edge. Table 2-83 The Time Measurement menu (Page 2/3) Menu Figure 2-138 Settings Settings Comments +Width Measure +Pulse Width of a pulse wave. -Width Measure –Pulse Width of a pulse wave. +Duty Measure +Duty Cycle of a pulse wave. -Duty Measure –Duty Cycle of a pulse wave. Table 2-84 The Time Measurement menu (Page 3/3) Menu Settings Comments Delay A→B Measure the signals delay between two channels at the rising edge. Delay A→B Measure the signals delay between two channels at the falling edge. Phase A B Measure the phase difference between two channels at the rising edge Phase A B Measure the phase difference between two channels at the falling edge User’s Guide for DS1000B Series 2-99 RIGOL Key Points: 1. Select the signal channel for measuring. CH1, CH2, CH3, CH4 according to the interest. Press soft buttons as follows: Measure→Source→CH1, CH2, CH3 , CH4. 2. To see all measurement values, Press No.2 button to set the Display All to ON. 18 measurement parameters will be displayed on the screen. 3. Select parameters page for measuring; press No.2 or No.3 button to select voltage or time parameters pages by pressing soft button as follows: Measure →Voltage or Time →Vmax, Vmin…… 4. To get the measured value on the screen; select the parameters of interest by pressing the soft button on the right of the menu, and read the data on the bottom of the screen. If the data is displayed as “*****”, it means the parameter cannot be measured in current condition. 5. Clear the measure values: press No.4 button Clear to clear away all of the auto measure values would disappear from the screen. 6. In Display All mode, there are 18 types of parameters could be used and the measuring result up to 3 are shown below the screen. When the display area are filled up 3 results, the new one will be displayed on the very right instating of the earliest, meanwhile the other two results removed left in turn. Turn on/off the mass measurement Clear Measured Parameters Figure 2-139 Explanation of the menu 2-100 User’s Guide for DS1000B series RIGOL To Measure with Cursors Figure 2-140 shows the Cursor button on the front-panel. Cursor Measurement Figure 2-140 The Cursor setup button The cursor measurement has three modes: Manual, Track and Auto Measure. 1. Manual In this mode, the screen displays two parallel cursors. Move the cursors to make custom voltage or time measurements of the signal. The values are displayed on the boxes below the menu. Before using cursors, make sure to set the Signal Source as the channel for measuring. 2. Track In this mode, the screen displays two cross cursors. The cross cursor sets the position on the waveform automatically. Adjust cursor’s horizontal position on the waveform by rotating the multifunctional knob ( ). The oscilloscope displays the values of the coordinates on the boxes below the menu. 3. Auto Measure This mode will take effect with Automatic Measurements. The instruments will display cursors while measuring parameters automatically. These cursors demonstrate the electrical meanings of these measurements. NOTE: The Auto Measure mode for Cursor measuring will take no effect without automatic measurement. User’s Guide for DS1000B Series 2-101 RIGOL Manual Mode Press Cursor→Mode→Manual to display the manual mode menu. Figure 2-141 Table 2-85 The Cursors menu Menu Mode Settings Manual X Type Y Source CH1 CH2 CH3 CH4 MATH Comments Adjust the cursor to parameters manually. measure X/Y Shown as vertical line to measure the time/frequency values. Shown as horizontal line to measure the voltage values. Select the measurement signal source. Time values of a pair X cursors and time increment can be measured in manual mode when selecting X type. (Frequency values and its increment of a pair X cursors can be measured when selecting MATH source.) Voltage values of a pair Y cursors and time increment can be measured in manual mode when selecting Y type. To do manual Cursor Measurements, please do as the following steps: 1. Select the Manual mode for cursor measurement by pressing soft button as: Cursor→Mode→Manual. 2. Select channel Source for measurements by pressing soft button as: Cursor→Source→CH1, CH2, CH3, CH4, MATH. NOTE: While measuring the channel with MATH, the results are valued with “d” (division) as units. 3. Select the cursors type by pressing soft button as Cursor→Type→ X or Y. 4. Move the cursors to adjust the increment between the cursors:(Details in the following Table) 2-102 User’s Guide for DS1000B series RIGOL Table 2-86 The Cursor menu Cursor Increment X Cursor A Y X Cursor B Y Operation Turn the multifunctional knob ( cursor A horizontally. Turn the multifunctional knob ( cursor A vertically. ) to move Turn the multifunctional knob ( cursor B horizontally. Turn the multifunctional knob ( cursor B vertically. ) to move ) to move ) to move NOTE: Cursor could be moved only when the curse function menu is displayed. 5. To get measurement values: Position of Cursor A: Time cursor centered on the midpoint of screen; Voltage cursor centered on channel ground level. Position of Cursor B: Same as above. Horizontal space between cursor A and B (△X): Time between cursors (1/△X), units in Hz, kHz, MHz, and GHz. Vertical space between cursor A and B (△Y): Voltage between cursors. NOTE: The values will be automatically displayed on the right upper corner of screen when the cursor function menu is hidden or displaying other menus. Term Explanations Cursor Y: Cursors Y appear as horizontal lines on the display to measure vertical parameters. Usually it is used to measure the Volts. When the source is set as function, the units are assigned to the function. Cursor X: Cursor X appears as vertical lines on the display to measure horizontal parameters. Usually it indicates the time of trigger excursion. When the source is set as FFT, X means frequency. User’s Guide for DS1000B Series 2-103 RIGOL Track Mode Press Cursor→Mode→Track to display the manual mode menu. Figure 2-142 Table 2-87 Cursor descriptions Menu Settings Mode Track Comments Set Track mode in cursor measurement. Cursor A CH1 CH2 CH3 CH4 MATH None Set Cursor A in conjunction Set Cursor A in conjunction Set Cursor A in conjunction Set Cursor A in conjunction Set Cursor A in conjunction Turn off Cursor A i with with with with with CH1. CH2. CH3. CH4. MATH. Cursor B CH1 CH2 CH3 CH4 MATH None Set Cursor B in conjunction Set Cursor B in conjunction Set Cursor B in conjunction Set Cursor B in conjunction Set Cursor B in conjunction Turn off Cursor B. with with with with with CH1. CH2. CH3. CH4. MATH. CurA (Cursor A) Turn the multifunctional Knob ( move cursor A Horizontally. ) to CurB (Cursor B) Turn the multifunctional knob ( move cursor B horizontally. ) to In cursor track mode, the cursors move together with the selected waveform. To do Track mode Cursor Measurements, follow these steps: 1. Select the Track mode for cursor measurement by pressing soft button as: Cursor→Mode→Track. 2. Select channel Source for Cursor A and Cursor B by pressing soft button as: Cursor→Cursor A or Cursor B→CH1, CH2, CH3, CH4, MATH or None. 3. Move the cursors to adjust the horizontal positions of the cursors: (Details in the following Table ) 2-104 User’s Guide for DS1000B series RIGOL Table 2-88 The Cursor usage Cursor Operation Cursor A Turn the multifunctional knob ( ) to move cursor A horizontally. Cursor B Turn the multifunctional knob ( ) to move Cursor B horizontally. NOTE: Moving cursor horizontally is not allowed when other (not tracking cursor) menu is activated. 4. To get measurement values: Position of Cursor A: Time cursor centered on the midpoint of screen; Voltage cursor centered on channel ground level. Position of Cursor B: Time cursor centered on the midpoint of screen; Voltage cursor centered on channel ground level. Read the horizontal space between Cursor A and B (△X): Time between cursors, units in seconds. (1/△X), units in Hz, kHz, MHz, GHz Vertical space between cursor A and B (△Y): Voltage between cursors, units in V. User’s Guide for DS1000B Series 2-105 RIGOL Auto mode Press Cursor→Mode→Auto to display the manual mode menu. Figure 2-143 Table 2-89 The Mode setting Menu Mode Settings Auto Comments Display the cursors for the current automatic measuring. (See the following figure). There will be no cursor display if no parameters are chosen in Measure menu. The oscilloscope could move cursor automatically to measure 22 parameters in Measure menu. Figure 2-144 Auto Measure Mode of Cursor Measurement 2-106 User’s Guide for DS1000B series RIGOL To Use Run Control Buttons The RUN control buttons include Auto (auto setting), Run/Stop and Single. Auto: The Auto features automatic adjustments to produce a stable display of the input signal. Press Auto button, the following menu appears. Figure 2-145 Table 2-90 The Auto menu Menu Settings Comments Multi-Cycle Press to display multi-cycle waveform on the screen. Single Cycle Press to display single cycle waveform on the screen. Rise Edge Fall Edge Undo User’s Guide for DS1000B Series Press to display the waveform’s rising edge and measure its rise time automatically. Press to display falling edge of the waveform and measure its fall time automatically. Press to cancel all the Auto Set actions, the oscilloscope will recover to its previous status. 2-107 RIGOL Auto-Set functions When the Auto is pressed the oscilloscope is configured to the following defaults: Table 2-91 The Auto menu Menu Settings Display format Y-T Acquire mode Normal Vertical Position Adjusted to right position Vertical “V/div” Adjusted to right scale Volts/Div Coarse Bandwidth limit Full Signal Invert OFF Horizontal position Center Horizontal “S/div” Adjust to right position. Trigger type Edge Trigger source Find the channel with input signal automatically. Trigger coupling DC Trigger voltage Midpoint setting Trigger mode Auto [1] NOTE: [1] The Bandwidth limit will turn on automatically as soon as measuring small signal. Run/Stop: Run or Stop waveform acquiring. NOTE: In Stop status, the volts/div and horizontal time base can be adjusted in a fixed limit. That is, to zoom in/out the signal in vertical and horizontal directions. Single: When running, press this key to stop the oscilloscope, when stopped, press this key to make a single acquisition when the trigger occurs, then stop. 2-108 User’s Guide for DS1000B series RIGOL Chapter 3 Application Examples Example 1: Taking Simple Measurements The function is used to observe an unknown signal; to display, measure frequency, and peak-to-peak amplitude. 1. (1) (2) (3) To quickly display a signal, please do the steps as follows: Set the probe [1] and the channel attenuations to 10X. Connect signal to CH1 with the probe. Press the Auto button. The oscilloscope sets the vertical, horizontal, and trigger controls at the best status automatically. To optimize the waveform display, adjust these controls manually to meet the requirements. 2. Selecting Automatic Measurements The oscilloscope takes automatic measurements on most signals. To measure the frequency and the peak-to-peak amplitude, do these steps as follows: (1) Measure peak-to-peak amplitude Press Measure→Source→CH1 to set the measurement source Press Voltage→Peak-Peak to select the peak-to-peak measurements and the result will be displayed on the screen. (2) Measure frequency Press Measure→Source→CH1 to set the measurement source Press Time→Freq to select the frequency measurements and the result will be displayed on the screen. NOTE: The frequency, period, and peak-to-peak measurements are shown on the screen and are updated periodically. Note: [1] For DS1204B, the standard probe is RP3300A which attenuation ratio is fixed at 10X and does not need to be adjusted. User’s Guide for DS1000B Series 3-1 RIGOL Example 2: View a Signal Delay Caused by a Circuit This example is to test the input and output signals of a circuit and observe the signal delay. First, set the probe [1] and the channel attenuation to 10X and connect CH1 probe to the input, CH2 to the output of the circuit. Do these steps as follow: 1. Display the signals (CH1 and CH2): (1) Press the Auto button. (2) Adjust the vertical and the horizontal scale by turning the set appropriate ranges for display. (3) Press the CH1 button to select Channel 1, and turn the vertical knob to adjust the vertical position of Channel 1 waveform. (4) Press the CH2 button to select Channel 2, and turn the vertical knob to adjust the vertical position of Channel 2 waveform. 2. Measure the delay time when a signal going through the circuit. Auto-measuring the delay: Press Measure→Source→CH1 to set the measurement source. knobs to Press Time to select the measurement Type. Press Delay A→B to display the result on the screen. You can see the change of the waveform in the following figure: Figure 3-1 Waveform distortion Note: [1] For DS1204B, the standard probe is RP3300A which attenuation ratio is fixed at 10X and does not need to be adjusted. 3-2 User’s Guide for DS1000B Series RIGOL Example 3: Capture a Single-Shot Signal To capture a single event, it needs to gather some pre-test knowledge of the signal in order to set up the trigger level and slope correctly. For example, if the event is derived from TTL logic, a trigger level of 2 volts should work on a rising edge. The following steps show how to use the oscilloscope to capture a single event. 1. Set the probe [1] and the channel attenuations to 10X. 2. Set up the trigger. (1) Press the MENU button in the Trigger control area to display the menu. (2) Press Edge to select the trigger mode. Press Slope to select . Press Source to select CH1. Press Sweep to select Single. Press Set Up→Coupling to select DC. (3) Turn the vertical and horizontal knobs to adjust the Volts/Div and the Time base in a proper range for the signal. (4) Turn the knob to adjust trigger level. (5) Press Run/Stop button to start capturing. When the trigger conditions are met, data appears on the display representing the data points that the oscilloscope obtained with one acquisition. This function helps to capture the occurrence easily, such as the noise with large amplitude; and set the trigger level higher a little above the normal level and press Run/Stop and wait. When noise occurs, the instrument will record the waveform before and after the trigger. Adjust the knob in the horizontal control area and change the level of the trigger position, will get the inverted delay trigger. It is useful to observe the waveform before the occurrence of the noise. Note: [1] For DS1204B, the standard probe is RP3300A which attenuation ratio is fixed at 10X and does not need to be adjusted. User’s Guide for DS1000B Series 3-3 RIGOL Example 4: To Reduce the Random Noise on a Signal If the signal is noisy (Figure 3-2), set up the oscilloscope to reduce the noise on the waveform and avoid its interference to the signal. Figure 3-2 Signal with noises 1. Set the probe [1] and the channel attenuations to 10X. 2. Connect a signal to the oscilloscope and obtain a stable display. 3. Improve the trigger by setting the Coupling. (1) Press the MENU in the Trigger control area. (2) Press Set Up→Coupling and select “LF Reject”. Low frequency reject, namely adding a high pass filter, filters out the low-frequency signal components (lower than 10kHz) while allows high-frequency signal components to pass. Or press Set Up→HF Reject and select “ON”. High frequency reject, namely adding a low pass filter, filters out the high-frequency signal components (greater than 100KHz, such as FM broadcast signal) while allows low frequency signal components to pass. Through LF Reject or HF Reject, low frequency or high frequency noise is rejected to obtain stable trigger. Note: [1] For DS1204B, the standard probe is RP3300A which attenuation ratio is fixed at 10X and does not need to be adjusted. 3-4 User’s Guide for DS1000B Series RIGOL 4. To reduce the noise by setting the acquisition type and adjust the waveform intensity. (1) If there is noise within the signal and the waveform looks too wide, in this case, choose average acquisition. In this mode the waveform will be thin and easy to observe and measure. To use average acquisition follows these steps. Press soft button as Acquire→Acquisition→Average Toggle the Averages soft button to select the number of averages that best eliminates the noise from the displayed waveform. It can be adjusted from 2 to 256. (See Figure 3-3) Figure 3-3 Signal without noises (2) To reduce the noise it can also be achieved by reducing the intensity of the display. NOTE: It is normal that the refresh rate will slow down when the average acquisition mode is ON. User’s Guide for DS1000B Series 3-5 RIGOL Example 5: Making Cursor Measurements There are 22 build-in automatic measurements. They can also be conducted using cursors to make time and voltage measurements of a waveform quickly. Measure the Peak Frequency of the First Sinc Waveform To 1. 2. 3. 4. 5. measure the rising frequency at the rising edge of a signal, do these steps: Press Cursor key to see the Cursor menu. Press Mode to set Manual mode. Press Type to select X. Turn ( ) knob to place cursor A on the first peak of the wave. Turn ( ) knob to place cursor B on the second peak of the wave. Observe the data in time and frequency displayed on the screen. Figure 3-4 Waveform display 3-6 User’s Guide for DS1000B Series RIGOL Measure the Amplitude of the First Waveform Peak of the Sinc. Please follow these steps: 1. 2. 3. 4. 5. Press Cursor key to see the Cursor menu. Press Mode to set Manual mode. Press Type to select Y. Turn ( ) knob to place cursor A on the first peak of the wave. Turn ( ) knob to place cursor B on the second peak of the wave. Observe the following measurements in the cursor menu: (See Figure 3-5) The delta voltage (peak-to-peak voltage of the waveform) The voltage at Cursor A The voltage at Cursor B Figure 3-5 Waveform display User’s Guide for DS1000B Series 3-7 RIGOL Example 6: The Application of the X-Y operation Viewing Phase Changes through a Network Theme: Connect the oscilloscope to monitor the input and output of the circuit and capture the phase changes. To view the input and output of the circuit in an X-Y display, do these steps: 1. From the probe menu set the attenuation to 10X. Set the switch to 10X on the probes [1]. 2. Connect the CH 1 probe to the input of the network, and connect the CH 2 probe to the output. 3. If the channels are not displayed, press the CH1 and CH2 buttons. 4. Press the AUTO button. 5. Adjust the vertical knob to display approximately the same amplitude signals on each channel. 6. Press the MENU in horizontal control area to display the menu. 7. Press the Time Base soft button to select X-Y. The oscilloscope displays a luscious pattern representing the input and output characteristics of the circuit. 8. Adjust the vertical and knobs to a desirable waveform display. 9. Apply the Ellipse method to observe the phase difference between the two channels. (See Figure 3-6) 3-8 User’s Guide for DS1000B Series RIGOL Signal must be centered in X D A B C Figure 3-6 Ellipse method to observe the phase difference Sinθ = A/B or C/D, where θ = phase shift (in degrees) between the two signals. From the formula above, you could get: θ = ±arcsine (A/B) or ±arcsine (C/D) θ must be in the range of (0~π/2) or (3π/2~2π) if the main axis of the ellipse is at I and III quadrant, If the main axis is at II and IV quadrant, θ must be in the range of (π/2~π) or (π~3π/2). Note: [1] For DS1204B, the standard probe is RP3300A which attenuation ratio is fixed at 10X and does not need to be adjusted. User’s Guide for DS1000B Series 3-9 RIGOL Example 7: Triggering on a Video Signal Test a video circuit in the DVD set. Use video trigger to obtain a stable display. Triggering on Video Fields To trigger on the video fields, please do as the following steps: 1. Press the MENU key in the Trigger control area to see the Trigger menu. 2. Press Mode to select Video. 3. Press Source to select CH1 as trigger source. 4. Press Polarity to select . 5. Press Sync as Odd Field or Even Field. 6. Adjust the stable trigger. 7. Turn the horizontal knob to set trigger level at the video sync pulse to get knob to see a complete waveform on the screen. Figure 3-7 Triggering on Video Fields DS1000B series triggers on the Odd field or Even field. To avoid confusion when Odd field and Even field trigger simultaneously, choose Odd field or Even field as step 5 above. 3-10 User’s Guide for DS1000B Series RIGOL Triggering on the Video Lines 1. 2. 3. 4. 5. 6. Press the MENU key in the Trigger control area to see the trigger menu. Press Mode to select Video. Press Source to select CH1 as trigger source. Press Polarity to select . Press Sync to select Line Num. Turn ( ) knob to trigger on a specified line number. 7. Adjust trigger. to set trigger level at the video sync pulse to get a stable 8. Turn the horizontal screen. knob to observe a complete waveform on the Figure 3-8 Triggering on the Video Lines User’s Guide for DS1000B Series 3-11 RIGOL Example 8: FFT Cursor Measurement FFT measurements include: Amplitude measurement (VRMS or dBVRMS) and Frequency measurement (Hz). Do these steps as follows: 1. Press Cursor→Press No.1 button to set cursor mode to Manual. 2. Press No.2 button associated with Type to select X or Y. 3. Press button MATH→set operate mode as FFT. 4. Press Cursor →press No.3 button to specify source as MATH. 5. Turn ( ) knob to move the cursor A and cursor B to a point of interest. Figure 3-9 Cursor Measurement (Type Y) Figure 3-10 Cursor Measurement (Type X) 3-12 User’s Guide for DS1000B Series RIGOL Example 9: Pass/Fail Test In Pass/Fail Test, the oscilloscope compares the input signal to the established waveform mask. Execute the steps as following: 1. 2. 3. 4. 5. 6. Press Utility→Pass/Fail. Press Enable Test and select ON. Press Mask Setting and then: Press Recall to a the saved mask or press X Mask and Y Mask to adjust the horizontal limit and vertical limit with the multifunctional knob then press Create Mask to create a new mask. Press Output to select the output condition: pass or fail and whether sound is included. Press Operate to start the test. Press Msg Display and select “ON” or “OFF”. When “ON” is selected, the test results would be displayed at the upper left corner of the screen. Figure 3-11 Waveform display User’s Guide for DS1000B Series 3-13 RIGOL Chapter 4 Troubleshooting 1. (1) (2) (3) (4) (5) After the oscilloscopes is powered on, the screen remains dark (no display): Check the power cord connection. Ensure the power switch is turned on. Check whether the fuse burns out or not. After the above inspection, restart the oscilloscope. If the problem still remains, please contact RIGOL for help. 2. (1) (2) (3) (4) After the signal acquisition the waveform does not appear: Check the probes connected with the signals. Check the probes connected to the channels firmly. Check the probes connected with the object being tested. Check the circuit generates signal at the test point (To judge whether channel or determinand in question, you can input the probe compensation output signal to a channel in question). (5) Repeat the acquisition. 3. The measurement result is 10 times higher or lower than the value expected. Check if the probe attenuation is the same as the channel attenuation. 4. If the oscilloscope does not get a stable waveform display: (1) Check the Trigger Source and notice if it is set to the channel in use. (2) Check the Trigger Type. Use “Edge” for normal signals, and use “Video” for VIDEO signals. (3) Switch the coupling into LF Reject in order to filter out the low frequency noise which disturbs the trigger or press HF Reject and select “ON” to filter out the high frequency noise that disturbs the trigger. (4) Adjust the trigger Sensitivity and the holdoff time. 5. After pressing the Run/Stop button, the oscilloscope does not display any waveform on screen. Check whether the Trigger Mode is set to “Normal” or “Single” and see whether the trigger level is out of the signal range. If yes, set the trigger level in knob or pressing the 50% button. Or set proper range by turning the User’s Guide for DS1000B Series 4-1 RIGOL the Trigger Mode as “AUTO”. Moreover, push Auto button to display the waveform on screen. 6. After the Acquisition is set to “Averages” or Display Persistence is set ON, the waveform refreshes slowly. It is normal in these settings. 7. The signal is displayed as ladder like waveform. (1) The time base setting maybe is too low. Turn the horizontal knob to increase horizontal resolution to improve the display. (2) Maybe the display Type is set to Vectors, and set it to Dots mode to improve the display. 8. Unable to connect to PC or the PictBridge printer by USB: (1) When connected to PC, if the message “Unknown device” appears or prompting scanner or camera was found. Press Utility to choose the I/O Setting menu, you may see the USB Device menu has been set to be “PictBridge”, you should switch it to “Auto Detect” or “Computer”. If necessary, restart the oscilloscope. (2) If connecting to a PictBridge printer or the printing is unsuccessful, maybe the USB Device menu has been set to “Computer”. You should switch it to be “Auto Detect” or “PictBridge”. If necessary, restart the oscilloscope. 4-2 User’s Guide for DS1000B Series RIGOL Chapter 5 Specifications All specifications apply to the DS1000B Series Oscilloscopes unless noted otherwise. To meet these specifications, two conditions must first be met: The instrument must have been operating continuously for thirty minutes within the specified operating temperature. Must perform the Self Cal operation, accessible through the Utility menu, if the operating temperature changes by more than 5°C. NOTE: All specifications are guaranteed unless noted “typical”. User’s Guide for DS1000B Series 5-1 RIGOL Technical Specifications Acquisition Sampling Modes Real-Time Equivalent-time [1] 50 GSa/s[2] Sampling Rate 2 GSa/s (half channel ) 1 GSa/s (each channel) Averages N time acquisitions, all channels simultaneously, N is selectable from 2, 4, 8, 16, 32, 64, 128 and 256 Inputs Input Coupling DC, AC, GND Input Impedance 1MΩ±2.0% The input capacity is 18pF±3pF Probe Attenuation Factors 0.001X, 0.01X, 0.1X, 1X, 2X, 5X, 10X, 20X, 50X, 100X, 200X, 500X, 1000X Maximum Input Voltage Maximum Input Voltage of the analog channel: CAT I 300Vrms, 1000Vpk; transient overvoltage 1000Vpk CAT II 100Vrms, 1000Vpk RP2200 10:1, CAT II 300Vrms RP3300A 10:1, CAT II 300Vrms Time delay between channel (typical) 500ps Horizontal Sample Rate Range 3.65Sa/s-2GSa/s (Real-Time), 3.65Sa/s-50GSa/s (Equivalent-time) Waveform interpolation Sin(x)/x Memory Depth 16k samples when horizontal timebase is 20ns/div or lower and 8k samples when horizontal timebase is 50ns/div or higher for half channel[1] 8k samples for each channel Scan speed Range (Sec/div) 5-2 1ns/div~50s/div, DS1204B 2ns/div~50s/div, DS1104B 5ns/div~50s/div, DS1074B 1-2-5 Sequence User’s Guide for DS1000B Series RIGOL Sample Rate and Delay Time Accuracy Delta Time Measurement Accuracy (Full Bandwidth) ±50ppm (over any≥1ms time interval) Single-shot: ±(1 sample interval + 50ppm × reading + 0.6 ns) >16 averages: ±(1sample interval + 50ppm × reading + 0.4 ns) Vertical A/D converter 8-bit resolution, each channel samples simultaneously Volts/div Range 2mV/div-10V/div at input BNC Offset Range ±40V(250mV/div ~10V/div) ±2V(2mV/div~245mV/div) Analog Bandwidth 70MHz(DS1074B) 100MHz(DS1104B) 200MHz(DS1204B) Single-shot Bandwidth 70MHz(DS1074B) 100MHz(DS1104B) 200MHz(DS1204B) Selectable Analog Bandwidth Limit 20MHz (typical) Lower Frequency Limit (AC -3dB) ≤5Hz (at input BNC) Rise Time at BNC, typical <1.75ns, <3.5ns, <5ns, On 200MHz, 100MHz, 70MHz respectively Dynamic range ±5div DC Gain Accuracy 2mV/div~5mV/div: ±4% (Normal or Average acquisition mode) 10mV/div~10V/div: ±3% (Normal or Average acquisition mode) DC Measurement Accuracy, Average Acquisition Mode Average of ≥16 Waveforms with vertical position at zero: ±(DC Gain Accuracy×reading+0.1div+1mV) Average of ≥16 Waveforms with vertical position not at zero: ±[DC Gain Accuracy×(reading+ vertical position)+(1% of vertical position)+0.2div] Add 2mV for settings from 2mV/div to 245 mV/div Add 50mV for settings from 250mV/div to 10V/div User’s Guide for DS1000B Series 5-3 RIGOL Delta Volts Measurement Accuracy (Average Acquisition Mode) Delta Volts between any two averages of 16 waveforms acquired under same setup and ambient conditions: ±(DC Gain Accuracy×reading + 0.05 div) Trigger Trigger Sensitivity 0.1div-1.0div (adjustable) Trigger Level Range Internal ±6 divisions from center of screen EXT ±1.2V EXT/5 ±6V Internal ±(0.3div × V/div)(±4 divisions from center of screen) EXT ±(6% of setting + 40 mV) EXT/5 ±(6% of setting + 200 mV) Trigger Level Accuracy (typical) applicable for the signal of rising and falling time ≥20ns Normal mode: pre-trigger(storage depth/(2×sampling) rate), delayed trigger 1s Trigger Offset Slow Scan mode: pre-trigger 6div, delayed trigger 6div Trigger Holdoff range 100ns~1.5s HF Rejection 100kHz ±20% LF Rejection 10kHz ±20% Set Level to (typical) 50% Input signal frequency ≥50Hz Edge Trigger Edge trigger slope Rising, Falling, Rising + Falling Pulse Trigger Trigger condition (>, <, =) Positive pulse, (>, <, =) negative pulse Pulse Width range 20ns ~10s Video Trigger Video standard & line frequency Support standard NTSC, PAL and SECAM broadcast systems. Line number range: 1~525 (NTSC) and 1~625 (PAL/SECAM) Pattern Trigger Pattern setup H, L, X, , Alternate Trigger Trigger on CH1, CH2, CH3, CH4 5-4 Edge, Pulse, Video User’s Guide for DS1000B Series RIGOL Measurements Manual Voltage difference between cursors (∆V) Time difference between cursors (∆T) Reciprocal of ∆T in Hertz (1/∆T) Track Voltage value for Y-axis waveform Time value for X-axis waveform Auto Cursors are visible for Automatic Measurement Cursor Auto Measure Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay A→B , Delay A→ B , Phase A→B ,Phase A→B NOTE: [1] Half channel indicates selecting one of the channels in CH1 and CH2, or in CH3 and CH4. [2] This is the highest specification, the specific specifications are as follows: DS1204B: 50GSa/s DS1104B: 25GSa/s DS1074B: 10GSa/s User’s Guide for DS1000B Series 5-5 RIGOL General Specifications Display Display Type 5.7 inch. (145 mm) diagonal TFT Liquid Crystal Display Display Resolution 320 horizontal ×RGB×240 vertical pixels Display Color 64k color Display Contrast (typical) 150:1 Backlight Brightness (typical) 300 nit Probe Compensator Output Output Voltage (typical) Approximately 3Vpp (peak to peak value) Frequency (typical) 1kHz Power Supply Voltage AC, 100~240 V, 45~440Hz, CAT II Power Consumption Less than 50W Fuse 2A, T rating, 250 V Environmental Ambient Temperature Operating 10℃~ 40℃ Non-operating -20℃~ +60℃ Cooling Method Fan force air flow Humidity +35℃ or below: ≤90% relative humidity +35℃~ +40℃: ≤60% relative humidity Altitude Operating 3,000 m or below Non-operating 15,000 m or below Mechanical Size Heavy Width 325mm Height 159mm Depth 133 mm Without package 3kg Packaged 4.3 kg IP Protection IP2X Calibration Interval The recommended calibration interval is one year 5-6 User’s Guide for DS1000B Series RIGOL Chapter 6 Appendixes Appendix A: DS1000B series Accessories Standard Accessories Passive Probes: RP2200 (1X or 10X, adjustable) for DS1074B/DS1104B RP3300A (10X) for DS1204B Note: 1X -- the probe has 6MHz bandwidth, according with 150V CAT II. 10X -- the probe’s bandwidth equals to the upper limit of the oscilloscope, according with 300V CAT II. A Power Cord that fits the standard of destination country. An USB Cable A CD-ROM (including User’s Guide an application software) A Quick Guide Optional Accessories: BNC Cable USB-GPIB Adapter 50Ω Impedance Adapter DS1000B special convenient soft bag All accessories (standard and optional) are available by contacting your local RIGOL office. User’s Guide for DS1000B Series 6-1 RIGOL Appendix B: Warranty RIGOL warrants its products’ mainframe and accessories in materials and workmanship within the warranty period. During the period concerned, RIGOL guarantees the free replacement or repair of products which are approved defective. To get repair service or obtain a copy of the whole warranty statement, please contact with your nearest RIGOL sales and service office. RIGOL do not provide any other warranty items except the one being provided by this summary and the warranty statement. The warranty items include but not being subjected to the hint guarantee items related to tradable characteristic and any particular purpose. RIGOL will not take any responsibility in cases regarding to indirect, particular and ensuing damage. 6-2 User’s Guide for DS1000B Series RIGOL Appendix C: General Care and Cleaning Do not store or leave the instrument in where the instrument will be exposed to direct sunlight for long periods of time. Caution To avoid damages to the instrument or probes, do not expose them to liquids which have causticity. Cleaning Clean the instrument and probes according to its operating conditions require. To clean the exterior surface, perform the following steps: 1. Disconnect the instrument from all power sources. 2. Clean the loose dust on the outside of the instrument and probes with a lintfree cloth (with a mild detergent and water). When clean the LCD, take care to avoid scarifying it. ! WARNING To avoid injury resulting from short circuit, make sure the instrument is completely dry before reconnecting into a power source. User’s Guide for DS1000B Series 6-3 RIGOL Index 50%........................................ 1-16 AC Coupling ............................... 2-6 AC Line ................................... 2-45 Accessories ................................ 6-2 Acquire.................................... 2-48 Acquisition ................................. 5-2 Alternative Trigger .................... 2-39 Appendix ................................... 6-1 AUTO .................................... 2-106 Auto Trigger ............................ 2-45 Automatic Measurement............ 2-90 Average Acquisition .................. 2-51 Bandwidth Limit ......................... 2-8 Blackman Window .................... 2-18 Channel Coupling ....................... 2-6 Cleaning .................................... 6-3 Coarse/Fine ............................. 1-12 Cursor ..................................... 2-99 Cursor Measurements ............... 2-99 DC Coupling ............................... 2-6 Display ...................................... 5-6 Display System......................... 2-52 Edge Trigger ............................ 2-33 Envelope ................................. 2-51 Equivalent Sampling ................. 2-51 Ext and Ext/5 ........................... 2-45 Factory Setup........................... 2-63 FFT ......................................... 2-16 FORCE .................................... 1-16 Front panel ................................ 1-3 Functional check ........................ 1-7 GND Coupling ............................ 2-7 Hamming Window .................... 2-18 User’s Guide for DS1000B Series Hanning Window ...................... 2-18 HF Reject ................................ 2-46 Horizontal .................................. 5-2 I/O setup................................. 2-66 Inputs ....................................... 5-2 Instant Execute Key................ 2-105 Invert a waveform .................... 2-13 Language ................................ 2-74 LF Reject ................................. 2-46 Measurements ........................... 5-4 Normal Trigger ......................... 2-46 Nyquist Frequency .................... 2-19 PictBridge ................................ 2-78 Power ....................................... 5-6 Pretrigger ................................ 2-46 Probe Attenuation ...................... 2-9 Probe compensation ................... 1-9 Probe Compensator .................... 5-6 Pulse Trigger ........................... 2-34 Random Noise............................ 3-4 Realtime Sampling .................... 2-51 Rectangle Window .................... 2-18 REF ......................................... 2-20 RUN/STOP ............................. 2-105 Sampling System ...................... 2-48 Save and Recal ........................ 2-55 Self- Calibration........................ 2-86 Single Trigger .......................... 2-46 Slope Trigger ........................... 2-37 Sync Pulses.............................. 2-36 Trigger ...................................... 5-4 Trigger Control ......................... 1-15 Trigger System......................... 2-32 1 RIGOL UTILITY................................... 2-64 Vertical ...................................... 5-3 Vertical System .......................... 2-2 2 Vertical Window ....................... 1-11 Video Signal ............................. 3-10 Video Trigger ........................... 2-35 User’s Guide for DS1000B Series .